PURPOSE: STereotactic Arrhythmia Radioablation (STAR) showed promising results in patients with refractory ventricular tachycardia. However, clinical data are scarce and heterogeneous. The STOPSTORM.eu consortium was established to investigate and harmonize STAR in Europe. The primary goal of this benchmark study was to investigate current treatment planning practice within the STOPSTORM project as a baseline for future harmonization. METHODS AND MATERIALS: Planning target volumes (PTVs) overlapping extracardiac organs-at-risk and/or cardiac substructures were generated for 3 STAR cases. Participating centers were asked to create single-fraction treatment plans with 25 Gy dose prescriptions based on in-house clinical practice. All treatment plans were reviewed by an expert panel and quantitative crowd knowledge-based analysis was performed with independent software using descriptive statistics for International Commission on Radiation Units and Measurements report 91 relevant parameters and crowd dose-volume histograms. Thereafter, treatment planning consensus statements were established using a dual-stage voting process. RESULTS: Twenty centers submitted 67 treatment plans for this study. In most plans (75%) intensity modulated arc therapy with 6 MV flattening filter free beams was used. Dose prescription was mainly based on PTV D95% (49%) or D96%-100% (19%). Many participants preferred to spare close extracardiac organs-at-risk (75%) and cardiac substructures (50%) by PTV coverage reduction. PTV D0.035cm3 ranged from 25.5 to 34.6 Gy, demonstrating a large variety of dose inhomogeneity. Estimated treatment times without motion compensation or setup ranged from 2 to 80 minutes. For the consensus statements, a strong agreement was reached for beam technique planning, dose calculation, prescription methods, and trade-offs between target and extracardiac critical structures. No agreement was reached on cardiac substructure dose limitations and on desired dose inhomogeneity in the target. CONCLUSIONS: This STOPSTORM multicenter treatment planning benchmark study not only showed strong agreement on several aspects of STAR treatment planning, but also revealed disagreement on others. To standardize and harmonize STAR in the future, consensus statements were established; however, clinical data are urgently needed for actionable guidelines for treatment planning.
- MeSH
- benchmarking * MeSH
- celková dávka radioterapie MeSH
- komorová tachykardie chirurgie radioterapie MeSH
- konsensus * MeSH
- kritické orgány * účinky záření MeSH
- lidé MeSH
- plánování radioterapie pomocí počítače * normy metody MeSH
- radiochirurgie * normy metody MeSH
- radioterapie s modulovanou intenzitou metody normy MeSH
- srdce účinky záření MeSH
- srdeční arytmie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND/PURPOSE: High doses to healthy cardiac substructures (CS) in stereotactic arrhythmia radioablation (STAR) raise concerns regarding potential treatment-induced cardio-toxicity. However, CS contours are not routinely created, hindering the understanding of the CS dose-effect relationships. To address this issue, the alignment of CS contouring was initiated within the STOPSTORM consortium. In this study, we developed and evaluated auto-contouring models trained to delineate CS and major vessels in ventricular tachycardia (VT) patients. METHODS: Eight centres provided standard treatment planning computed tomography (CT) and/or contrast-enhanced CT datasets of 55 VT patients, each including 16 CS. Auto-contouring models were trained to contour either large structures or small structures. Dice Similarity Coefficient (DSC), 95 % Hausdorff distance (HD95) and volume ratio (VR) were used to evaluate model performance versus inter-observer variation (IOV) on seven VT patient test cases. Significant differences were tested using the Mann-Whitney U test. RESULTS: The performance on the four chambers and the major vessels (median DSC: 0.88; HD95: 5.8-19.4 mm; VR: 1.09) was similar to the IOV (median DSC: 0.89; HD95: 4.8-14.0 mm; VR: 1.20). For the valves, model performance (median DSC: 0.37; HD95: 11.6 mm; VR: 1.63) was similar to the IOV (median DSC: 0.41; HD95: 12.4 mm; VR: 3.42), but slightly worse for the coronary arteries (median DSC: 0.33 vs 0.42; HD95: 24.4 mm vs 16.9 mm; VR: 1.93 vs 3.30). The IOV for these small structures remains large despite using contouring guidelines. CONCLUSION: CS auto-contouring models trained on VT patient data perform similarly to IOV. This allows for time-efficient evaluation of CS as possible organs-at-risk.
- MeSH
- komorová tachykardie * MeSH
- kritické orgány účinky záření MeSH
- lidé středního věku MeSH
- lidé MeSH
- plánování radioterapie pomocí počítače metody MeSH
- počítačová rentgenová tomografie * MeSH
- radiochirurgie * metody MeSH
- senioři MeSH
- srdce účinky záření MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
PURPOSE: The optimal motion management strategy for patients receiving stereotactic arrhythmia radioablation (STAR) for the treatment of ventricular tachycardia (VT) is not fully known. We developed a framework using a digital phantom to simulate cardiorespiratory motion in combination with different motion management strategies to gain insight into the effect of cardiorespiratory motion on STAR. METHODS AND MATERIALS: The 4-dimensional (4D) extended cardiac-torso (XCAT) phantom was expanded with the 17-segment left ventricular (LV) model, which allowed placement of STAR targets in standardized ventricular regions. Cardiac- and respiratory-binned 4D computed tomography (CT) scans were simulated for free-breathing, reduced free-breathing, respiratory-gating, and breath-hold scenarios. Respiratory motion of the heart was set to population-averaged values of patients with VT: 6, 2, and 1 mm in the superior-inferior, posterior-anterior, and left-right direction, respectively. Cardiac contraction was adjusted by reducing LV ejection fraction to 35%. Target displacement was evaluated for all segments using envelopes encompassing the cardiorespiratory motion. Envelopes incorporating only the diastole plus respiratory motion were created to simulate the scenario where cardiac motion is not fully captured on 4D respiratory CT scans used for radiation therapy planning. RESULTS: The average volume of the 17 segments was 6 cm3 (1-9 cm3). Cardiac contraction-relaxation resulted in maximum segment (centroid) motion of 4, 6, and 3.5 mm in the superior-inferior, posterior-anterior, and left-right direction, respectively. Cardiac contraction-relaxation resulted in a motion envelope increase of 49% (24%-79%) compared with individual segment volumes, whereas envelopes increased by 126% (79%-167%) if respiratory motion also was considered. Envelopes incorporating only the diastole and respiration motion covered on average 68% to 75% of the motion envelope. CONCLUSIONS: The developed LV-segmental XCAT framework showed that free-wall regions display the most cardiorespiratory displacement. Our framework supports the optimization of STAR by evaluating the effect of (cardio)respiratory motion and motion management strategies for patients with VT.
- MeSH
- čtyřrozměrná počítačová tomografie MeSH
- dýchání * MeSH
- fantomy radiodiagnostické MeSH
- lidé MeSH
- pohyb těles MeSH
- srdce * diagnostické zobrazování účinky záření MeSH
- srdeční arytmie MeSH
- srdeční komory diagnostické zobrazování účinky záření MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Part of the current stereotactic arrythmia radioablation (STAR) workflow is transfer of findings from the electroanatomic mapping (EAM) to computed tomography (CT). Here, we analyzed inter- and intraobserver variation in a modified EAM-CT registration using automatic registration algorithms designed to yield higher robustness. MATERIALS AND METHODS: This work is based on data of 10 patients who had previously undergone STAR. Two observers participated in this study: (1) an electrophysiologist technician (cardiology) with substatial experience in EAM-CT merge, and (2) a clinical engineer (radiotherapy) with minimum experience with EAM-CT merge. EAM-CT merge consists of 3 main steps: segmentation of left ventricle from CT (CT LV), registration of the CT LV and EAM, clinical target volume (CTV) delineation from EAM specific points. Mean Hausdorff distance (MHD), Dice Similarity Coefficient (DSC) and absolute difference in Center of Gravity (CoG) were used to assess intra/interobserver variability. RESULTS: Intraobserver variability: The mean DSC and MHD for 3 CT LVs altogether was 0.92 ± 0.01 and 1.49 ± 0.23 mm. The mean DSC and MHD for 3 CTVs altogether was 0,82 ± 0,06 and 0,71 ± 0,22 mm. Interobserver variability: Segmented CT LVs showed great similarity (mean DSC of 0,91 ± 0,01, MHD of 1,86 ± 0,47 mm). The mean DSC comparing CTVs from both observers was 0,81 ± 0,11 and MHD was 0,87 ± 0,45 mm. CONCLUSIONS: The high interobserver similarity of segmented LVs and delineated CTVs confirmed the robustness of the proposed method. Even an inexperienced user can perform a precise EAM-CT merge following workflow instructions.
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Stereotactic ablative radiotherapy (SABR) is the standard treatment for medically inoperable early-stage non-small cell lung cancer (ES-NSCLC), but which patients benefit from stereotactic radiotherapy is unclear. The aim of this study was to analyze prognostic factors for early mortality. METHODS: From August 2010 to 2022, 617 patients with medically inoperable, peripheral or central ES-NSCLC were treated with SABR at our institution. We retrospectively evaluated the data from 172 consecutive patients treated from 2018 to 2020 to analyze the prognostic factors associated with overall survival (OS). The biological effective dose was > 100 Gy10 in all patients, and 60 Gy was applied in 3-5 fractions for a gross tumor volume (GTV) + 3 mm margin when the tumor diameter was < 1 cm; 30-33 Gy was delivered in one fraction. Real-time tumor tracking or an internal target volume approach was applied in 96% and 4% of cases, respectively. In uni- and multivariate analysis, a Cox model was used for the following variables: ventilation parameter FEV1, histology, age, T stage, central vs. peripheral site, gender, pretreatment PET, biologically effective dose (BED), and age-adjusted Charlson comorbidity index (AACCI). RESULTS: The median OS was 35.3 months. In univariate analysis, no correlation was found between OS and ventilation parameters, histology, PET, or centrality. Tumor diameter, biological effective dose, gender, and AACCI met the criteria for inclusion in the multivariate analysis. The multivariate model showed that males (HR 1.51, 95% CI 1.01-2.28; p = 0.05) and AACCI > 5 (HR 1.56, 95% CI 1.06-2.31; p = 0.026) were significant negative prognostic factors of OS. However, the analysis of OS showed that the significant effect of AACCI > 5 was achieved only after 3 years (3-year OS 37% vs. 56%, p = 0.021), whereas the OS in one year was similar (1-year OS 83% vs. 86%, p = 0.58). CONCLUSION: SABR of ES-NSCLC with precise image guidance is feasible for all medically inoperable patients with reasonable performance status. Early deaths were rare in our real-life cohort, and OS is clearly higher than would have been expected after best supportive care.
- MeSH
- analýza přežití MeSH
- kohortové studie MeSH
- lidé MeSH
- malobuněčný karcinom plic * patologie MeSH
- nádory plic * radioterapie chirurgie MeSH
- nemalobuněčný karcinom plic * radioterapie chirurgie MeSH
- radiochirurgie * metody MeSH
- retrospektivní studie MeSH
- staging nádorů MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Publikační typ
- abstrakt z konference MeSH
INTRODUCTION: In the era of personalized medicine and treatment optimization, use of immune biomarkers holds promise for estimating the prognosis of patients with head and neck squamous cell carcinoma (HNSCC) undergoing definitive treatment. METHODS: To evaluate the prognostic potential of immune biomarkers, we conducted a prospective monocentric cohort study with loco-regionally advanced HNSCC patients indicated for definitive radiotherapy/radiochemotherapy at the Department of Oncology, Ostrava University Hospital, Czech Republic, between June 2020 and August 2023. We focused on the expression of programmed death ligand 1 (PD-L1) and tumor-infiltrating lymphocytes (TILs) relative to overall survival (OS) and specific survival rates. Associations between biomarkers and survival rates were assessed by crude and adjusted hazard ratios (cHR, aHR, respectively) obtained from Cox proportional hazards regression. RESULTS: Among a total of 55 patients within a median follow-up of 19.7 months, there were 21 (38.2%) all-cause deaths and 15 (27.3%) cancer-related deaths. An overall survival (OS) rate of 61.8% and a disease-specific survival (DSS) rate of 72.7% were recorded. A significant association between survival rates and a ≥10% difference in PD-L1 expression on immune versus tumor cells (high PD-L1IC expression) was documented regardless of the type of analysis (univariate or multivariate). In addition, a stronger association was confirmed for OS and the composite biomarker high PD-L1IC expression along with either median-higher CD8+ TIL count or increased TIL density ≥30%, as indicated by an aHR of 0.08 (95% CI, 0.01 to 0.52) and 0.07 (95% CI, 0.01 to 0.46), respectively. Similar results were demonstrated for other specific survival rates. DISCUSSION: The early outcomes of the present study suggest the utility of a strong prognostic factor involving a composite biomarker high PD-L1IC expression along with increased TIL density in HNSCC patients undergoing definitive radiotherapy and radiochemotherapy. TRIAL REGISTRATION: The study is registered with Clinicaltrials.gov. - NCT05941676.
- Publikační typ
- časopisecké články MeSH
We performed a histological and immunohistochemical analysis of myocardia from 3 patients who underwent radiosurgery and died for various reasons 3 months to 9 months after radiotherapy. In Case 1 (death 3 months after radiotherapy) we observed a sharp transition between relatively intact and irradiated regions. In the myolytic foci, only scattered cardiomyocytes were left and the area was infiltrated by immune cells. Using immunohistochemistry we detected numerous inflammatory cells including CD68+/CD11c+ macrophages, CD4+ and CD8+ T-lymphocytes and some scattered CD20+ B-lymphocytes. Mast cells were diminished in contrast to viable myocardium. In Case 2 and Case 3 (death 6 and 9 months after radiotherapy, respectively) we found mostly fibrosis, infiltration by adipose tissue and foci of calcification. Inflammatory infiltrates were less pronounced. Our observations are in accordance with animal experimental studies and confirm a progress from myolysis to fibrosis. In addition, we demonstrate a role of pro-inflammatory macrophages in the earlier stages of myocardial remodeling after stereotactic radioablation for ventricular tachycardia.
- MeSH
- fibróza MeSH
- komorová tachykardie * etiologie radioterapie chirurgie MeSH
- lidé MeSH
- radiochirurgie * škodlivé účinky MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Úvod: Stereotaktická radioterapie (SBRT) je moderní metodou v zevní radioterapii. Přináší možnost aplikovat vysokou dávku záření s vyšší biologickou účinností do malého cílového objemu. Zabývali jsme se pacienty s karcinomem štítné žlázy indikovaných k této terapii. Pacienti a metody: Retrospektivně jsme zhodnotili soubor pacientů s diferencovaným karcinomem štítné žlázy z období let 2011 až 2019 indikovaných k této léčbě pro přetrvávající reziduum. Výsledky: V daném období 9 let podstoupilo terapii z důvodu přetrvávajícího rezidua 14 pacientů, 10 žen, 4 muži. Radiojód akumulující reziduum bylo před terapií přítomno u 9 pacientů, 5 pacientů bylo indikováno na základě elevované hladiny tyreoglobulinu (Tg) a rezidua přítomného na jiných zobrazovacích metodách. Po terapii došlo k plné nebo parciální regresi radiojód akumulujícího rezidua ve šech 9 případech. U 5 pacientů bez radiojód akumulujícího rezidua nedošlo k progresi ložiska na zobrazovacích metodách, odpověď ve sledované hladině Tg byla variabilní. Závěr: Radioterapie pomocí robotického systému CyberKnife představuje další léčebnou modalitu u pacientů s diferencovaným karcinomem štítné žlázy, umožňující lokální kontrolu nemoci.
Introduction: Stereotactic body radiation therapy (SBRT) is a modern method in external radiation therapy. It offers an option to use a high dose of radiation with a higher biological effect in a small target volume. We assessed the patients with the thyroid cancer indicated to this type of therapeutic approach. Patients and methods: We evaluated a group of patients with the differentiated thyroid cancer retrospectively, indicated to SBRT for the persisting residuals on the neck, from the time interval 2011–2019. Results: During the nine years interval, 14 patients (10 female, 4 male), underwent this type of therapy. Radioiodine accumulating remnants were present before SBRT in 9 patients, higher thyroglobulin (Tg) levels or residuals diagnosed by other imaging modalities were indications in 5 patients. The radioiodine accumulating residuals regressed fully or partially in all 9 cases. In the later 5 patients there was not observed any progression on the imaging examinations, response according to the thyroglobulin levels was variable. Conclusion: SBRT with the robotic CyberKnife system represents another therapeutic modality for patients with differentiated thyroid cancer, allowing local control of the disease.
- MeSH
- lidé MeSH
- nádory štítné žlázy * radioterapie MeSH
- radiochirurgie metody MeSH
- retrospektivní studie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH