AIMS: We report our single-centre experience of mid-term to long-term retrieval and reimplantation of a tine-based leadless pacemaker [Micra transcatheter pacing system (TPS)]. The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favourable in specific scenarios. METHODS AND RESULTS: We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7 mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. After an implantation duration of 3.1 ± 2.8 years (range 0.4-9.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 ± 16 min, and the fluoroscopy time was 18.0 ± 6.6 min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications. CONCLUSION: A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- echokardiografie MeSH
- intervenční radiografie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor * MeSH
- lidé středního věku MeSH
- lidé MeSH
- odstranění implantátu * metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční katetrizace * metody přístrojové vybavení MeSH
- srdeční katétry MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Visually guided laser balloon ablation is known as an effective pulmonary vein (PV) isolation device. The third-generation laser balloon ablation system (X3) equipped with compliant balloon and an automated motor-driven laser output mechanism, namely RAPID mode, has been clinically proven for PV isolation. METHODS: PV isolation with X3 was performed in all the patients with paroxysmal and early-stage persistent atrial fibrillation (AF). Acute data for PV isolation and clinical outcomes including supraventricular tachyarrhythmia (SVT: AF, atrial flutter, or atrial tachycardia)-free survival rate beyond 1 year were analyzed. RESULTS: A total of 110 patients (62 ± 13 years old, 80% of paroxysmal AF) were treated with X3. RAPID mode with was utilized to achieve PV isolation in all cases. In combination with RAPID mode and spot mode laser ablation, 91.1% (380/417) of veins were isolated on the first circumferential lesion set and did not require touch-up ablation and during the index procedure 100% of attempted veins were isolated. The mean procedure time was 77.0 ± 22.7 min and LA dwell time was 61.9 ± 22.0 min. Total duration of laser application was 5.1 ± 2.3 min per vein. At 1 year, SVT-free survival rate was 93.7% in paroxysmal AF patients, and 81.1% in persistent AF patients. CONCLUSIONS: A novel continuous automatic laser balloon ablation system was proved to be safe and effective for both paroxysmal and persistent AF patients. The clinical result demonstrated that PV isolation with X3 could achieve a high SVT-free survival rate.
BACKGROUND: During atrial fibrillation ablations using thermal energy, the treatment effect is attributed to not just pulmonary vein isolation (PVI), but also to modulation of the autonomic nervous system by ablation of cardiac ganglionated plexi (GP). OBJECTIVES: This study sought to assess the impact of pulsed field ablation (PFA) on the GP in patients undergoing PVI. METHODS: In the retrospective phase, heart rate was assessed pre- versus post-PVI using PFA, cryoballoon ablation, or radiofrequency ablation. In the prospective phase, a pentaspline PFA catheter was used in a protocol: 1) pre-PFA, high-frequency stimulation (HFS) identified GP sites by vagal effects; 2) PVI was performed assessing for repetitive vagal effects over each set of PF applications; 3) mapping defined PVI extent to identify those GP in the ablation zone; and 4) repeat HFS at GP sites to assess for persistence of vagal effects. RESULTS: Between baseline and 3 months, heart rates in the retrospective radiofrequency ablation (n = 40), cryoballoon (n = 40), and PFA (n = 40) cohorts increased by 8.9 ± 11.4, 11.1 ± 9.4, and -0.1 ± 9.2 beats/min, respectively (P= 0.01 PFA vs radiofrequency ablation; P= 0.01 PFA vs cryoballoon ablation). In the prospective phase, pre-PFA HFS in 20 additional patients identified 65 GP sites. During PFA, vagal effects were noted in 45% of first PF applications, persisting through all applications in 83%. HFS post-PFA reproduced vagal effects in 29 of 38 sites (76%) in low-voltage tissue. CONCLUSIONS: PFA has minimal effect on GP. Unlike with thermal ablation, the mechanism by which PFA treats atrial fibrillation is mediated solely by durable PVI.
- MeSH
- fibrilace síní * MeSH
- katetrizační ablace * škodlivé účinky MeSH
- lidé MeSH
- nervus vagus chirurgie MeSH
- prospektivní studie MeSH
- retrospektivní studie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND AND PURPOSE: Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. METHODS: The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 °C, max 50 W). Acute and chronic efficacy and safety was evaluated. RESULTS: Seventy-one patients (age 69.9 ± 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 ± 6.1 min and 20.6 ± 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). CONCLUSION: This first in man series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA. TRIAL REGISTRATION: Registered on the site ClinicalTrials.gov January 2016 with identifier: NCT02821351.
- MeSH
- design vybavení MeSH
- fibrilace síní * MeSH
- katetrizační ablace * škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- teplota MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- multicentrická studie MeSH
- MeSH
- defibrilátory implantabilní * MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- nádory * radioterapie MeSH
- radioterapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- směrnice pro lékařskou praxi MeSH
odborného stanoviska poskytuje rámcový přehled potenciálních poruch funkce kardiostimulátorů a kardioverterů-defibrilátorů v souvislosti s radioterapií a navrhuje metodický postup pro průběh celého procesu radioterapie u pacientů s implantovanými kardiostimulátory nebo kardiovertery-defibrilátory. Je určen pro radiační onkology, kardiology, arytmology, radiologické fyziky a techniky, biomedicínské techniky a inženýry, radiologické asistenty, zdravotní sestry a další zdravotnické pracovníky, kteří se podílejí na léčbě těchto pacientů
The summary of the consesus document provides the framework that analyzes the potential failure modes of implanted cardiac devices (implantable cardiac pacemakers and implantable cardioverter-defibrillators - cardiac implantable electronic devices) in context of radiotherapy procedures and proposes the methodology for patient management in every step of the entire radiotherapy process. The summary is intended for radiation oncologists, cardiologists, arrhythmologists, medical physicists, dosimetrists, clinical engineers and technicians, nurses and other health professionals, that partake in the treatment of patients with such devices.
- MeSH
- bezpečnost pacientů MeSH
- defibrilátory implantabilní * MeSH
- kardiostimulátor * MeSH
- lidé MeSH
- management péče o pacienta MeSH
- radioterapie * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- směrnice pro lékařskou praxi MeSH
OBJECTIVES: This study sought to determine whether durable pulmonary vein isolation (PVI) using pulsed field ablation (PFA) translates to freedom from atrial fibrillation recurrence without an increase in adverse events. BACKGROUND: PFA is a nonthermal ablative modality that, in preclinical studies, is able to preferentially ablate myocardial tissue with minimal effect on surrounding tissues. Herein, we present 1-year clinical outcomes of PFA. METHODS: In 3 multicenter studies (IMPULSE [A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation], PEFCAT [A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation], and PEFCAT II [Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation]), paroxysmal atrial fibrillation patients underwent PVI using a basket or flower PFA catheter. Invasive remapping was performed at ∼2 to 3 months, and reconnected PVs were reisolated with PFA or radiofrequency ablation. After a 90-day blanking period, arrhythmia recurrence was assessed over 1-year follow-up. RESULTS: In 121 patients, acute PVI was achieved in 100% of PVs with PFA alone. PV remapping, performed in 110 patients at 93.0 ± 30.1 days, demonstrated durable PVI in 84.8% of PVs (64.5% of patients), and 96.0% of PVs (84.1% of patients) treated with the optimized biphasic energy PFA waveform. Primary adverse events occurred in 2.5% of patients (2 pericardial effusions or tamponade, 1 hematoma); in addition, there was 1 transient ischemic attack. The 1-year Kaplan-Meier estimates for freedom from any atrial arrhythmia for the entire cohort and for the optimized biphasic energy PFA waveform cohort were 78.5 ± 3.8% and 84.5 ± 5.4%, respectively. CONCLUSIONS: PVI with a "single-shot" PFA catheter results in excellent PVI durability and acceptable safety with a low 1-year rate of atrial arrhythmia recurrence. These data mitigate concern that the nonthermal ablative mechanism of PFA might mask undiscovered compromises to clinical success. (IMPULSE: A Safety and Feasibility Study of the IOWA Approach Endocardial Ablation System to Treat Atrial Fibrillation, NCT03700385; A Safety and Feasibility Study of the FARAPULSE Endocardial Ablation System to Treat Paroxysmal Atrial Fibrillation, NCT03714178; PEFCAT II Expanded Safety and Feasibility Study of the FARAPULSE Endocardial Multi Ablation System to Treat Paroxysmal Atrial Fibrillation [PEFCAT II], NCT04170608).
[Figure: see text].
- MeSH
- akční potenciály MeSH
- časové faktory MeSH
- délka operace MeSH
- design vybavení MeSH
- doba přežití bez progrese choroby MeSH
- endoskopie škodlivé účinky přístrojové vybavení MeSH
- endoskopy * MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- katetrizační ablace škodlivé účinky přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- recidiva MeSH
- senioři MeSH
- srdeční frekvence MeSH
- studie případů a kontrol MeSH
- venae pulmonales patofyziologie chirurgie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- audiovizuální média MeSH
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH