Je něco špatně v tomto záznamu ?
Multi-analyte surface plasmon resonance biosensing
Homola J, Vaisocherová H, Dostálek J, Piliarik M.
Jazyk angličtina Země Spojené státy americké
- MeSH
- biosenzitivní techniky metody MeSH
- financování organizované MeSH
- povrchová plasmonová rezonance MeSH
Surface plasmon resonance (SPR) biosensors are affinity sensing devices exploiting a special mode of electromagnetic field-surface plasmon-polariton-to detect the binding of analyte molecules from a liquid sample to biomolecular recognition elements immobilized on the surface of the sensor. In this paper, we review advances of SPR biosensor technology towards detection systems for the simultaneous detection of multiple analytes (multi-analyte detection). In addition, we report application of a recently developed multichannel SPR sensor based on spectroscopy of surface plasmons and wavelength division multiplexing of sensing channels to multi-analyte detection.
Citace poskytuje Crossref.org
- 000
- 01926naa 2200301 a 4500
- 001
- bmc07507243
- 003
- CZ-PrNML
- 005
- 20111210122845.0
- 008
- 080801s2005 xxu e eng||
- 009
- AR
- 024 __
- $a 10.1016/j.ymeth.2005.05.003 $2 doi
- 035 __
- $a (PubMed)16199172
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Homola, Jiří $7 xx0039276
- 245 10
- $a Multi-analyte surface plasmon resonance biosensing / $c Homola J, Vaisocherová H, Dostálek J, Piliarik M.
- 314 __
- $a Institute of Radio Engineering and Electronics, Academy of Sciences of the Czech Republic, Chaberská 57, 18251 Prague, Czech Republic. homola@ure.cas.cz
- 520 9_
- $a Surface plasmon resonance (SPR) biosensors are affinity sensing devices exploiting a special mode of electromagnetic field-surface plasmon-polariton-to detect the binding of analyte molecules from a liquid sample to biomolecular recognition elements immobilized on the surface of the sensor. In this paper, we review advances of SPR biosensor technology towards detection systems for the simultaneous detection of multiple analytes (multi-analyte detection). In addition, we report application of a recently developed multichannel SPR sensor based on spectroscopy of surface plasmons and wavelength division multiplexing of sensing channels to multi-analyte detection.
- 650 _2
- $a biosenzitivní techniky $x metody $7 D015374
- 650 _2
- $a povrchová plasmonová rezonance $7 D020349
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Vaisocherová, Hana. $7 _AN027052
- 700 1_
- $a Dostálek, Jakub. $7 stk2008461786
- 700 1_
- $a Piliarik, Marek. $7 _AN027055
- 773 0_
- $w MED00005029 $t Methods $g Roč. 37, č. 1 (2005), s. 26-36 $x 1046-2023
- 910 __
- $a ABA008 $b x $y 9
- 990 __
- $a 20080721085927 $b ABA008
- 991 __
- $a 20111026135336 $b ABA008
- 999 __
- $a ok $b bmc $g 622849 $s 475282
- BAS __
- $a 3
- BMC __
- $a 2005 $b 37 $c 1 $d 26-36 $i 1046-2023 $m Methods $x MED00005029
- LZP __
- $a 2008-Doreen