Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

The influence of galvanic currents and voltage on the proliferation activity of lymphocytes and expression of cell surface molecules

Štěpán Podzimek, Karel Hána, Martin Mikšovský, Lubomír Poušek, Petr Matucha, Milan Meloun, Jarmila Procházková

. 2008 ; 54 (5) : 146-150.

Language English Country Czech Republic

Release of metal ions from dental metal fillings supported by galvanism can cause local or general pathological problems in sensitive and genetically susceptible individuals. We aimed to investigate in vitro lymphocyte responses and expression of surface molecules influenced by galvanic currents and voltage. Human peripheral blood lymphocytes were influenced by galvanic currents and voltages and lymphocyte proliferation was measured. Control samples were not exposed to the influence of galvanism. We also studied the expression of surface molecules by the FACS analysis. A 15-h and shorter influence of almost all tested currents and voltages caused a significant decrease in lymphocyte proliferation and the 15-h influence of 20 microA currents significantly increased expression of surface molecules CD 19, 11a/18, 19/69 and 19/95. An influence of 10 and 3 microA currents led to a significant decrease in the expression of surface molecules CD 3, 11a/18, 3/69 and 3/95 and to a significant increase in CD 19 expression. An 80 mV voltage influence led to a significant decrease in the expression of surface molecules CD 3, 11a/18, 3/69, 3/95, 19/69 and 19/95, and 200 and 300 mV voltages significantly decreased the expression of surface molecules CD 3, 19, 11a/18, 3/95 and 19/95 and significantly increased CD 19/69 expression. A long-lasting influence of galvanism can, in sensitive and genetically susceptible individuals, influence lymphocyte proliferation and surface molecule expression. The threshold for pathological values of 5 microA for galvanic currents and 100 mV for galvanic voltage was confirmed.

Bibliography, etc.

Lit.: 29

000      
00000naa 2200000 a 4500
001      
bmc07523187
003      
CZ-PrNML
005      
20111210134649.0
008      
090514s2008 xr e eng||
009      
AR
035    __
$a (PubMed)19178813
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Podzimek, Štěpán, $d 1976- $7 xx0106917
245    14
$a The influence of galvanic currents and voltage on the proliferation activity of lymphocytes and expression of cell surface molecules / $c Štěpán Podzimek, Karel Hána, Martin Mikšovský, Lubomír Poušek, Petr Matucha, Milan Meloun, Jarmila Procházková
314    __
$a Charles University in Prague, First Faculty of Medicine and General Teaching Hospital, Institute of Dental Research, Prague
504    __
$a Lit.: 29
520    9_
$a Release of metal ions from dental metal fillings supported by galvanism can cause local or general pathological problems in sensitive and genetically susceptible individuals. We aimed to investigate in vitro lymphocyte responses and expression of surface molecules influenced by galvanic currents and voltage. Human peripheral blood lymphocytes were influenced by galvanic currents and voltages and lymphocyte proliferation was measured. Control samples were not exposed to the influence of galvanism. We also studied the expression of surface molecules by the FACS analysis. A 15-h and shorter influence of almost all tested currents and voltages caused a significant decrease in lymphocyte proliferation and the 15-h influence of 20 microA currents significantly increased expression of surface molecules CD 19, 11a/18, 19/69 and 19/95. An influence of 10 and 3 microA currents led to a significant decrease in the expression of surface molecules CD 3, 11a/18, 3/69 and 3/95 and to a significant increase in CD 19 expression. An 80 mV voltage influence led to a significant decrease in the expression of surface molecules CD 3, 11a/18, 3/69, 3/95, 19/69 and 19/95, and 200 and 300 mV voltages significantly decreased the expression of surface molecules CD 3, 19, 11a/18, 3/95 and 19/95 and significantly increased CD 19/69 expression. A long-lasting influence of galvanism can, in sensitive and genetically susceptible individuals, influence lymphocyte proliferation and surface molecule expression. The threshold for pathological values of 5 microA for galvanic currents and 100 mV for galvanic voltage was confirmed.
650    _2
$a CD antigeny $x metabolismus $7 D015703
650    _2
$a biologické markery $x metabolismus $7 D015415
650    _2
$a buněčná membrána $x metabolismus $7 D002462
650    _2
$a proliferace buněk $7 D049109
650    _2
$a elektrická stimulace $7 D004558
650    _2
$a elektřina $7 D004560
650    _2
$a lidé $7 D006801
650    _2
$a lymfocyty $x cytologie $x mikrobiologie $7 D008214
700    1_
$a Hána, Karel, $d 1970- $7 ntka172706
700    1_
$a Mikšovský, Martin $7 xx0093455
700    1_
$a Poušek, Lubomír, $d 1955- $7 ntka173769
700    1_
$a Matucha, Petr $7 xx0092177
700    1_
$a Meloun, Milan, $d 1943- $7 nlk19990073554
700    1_
$a Procházková, Jarmila, $d 1957- $7 xx0061395
773    0_
$w MED00011004 $t Folia biologica $g Roč. 54, č. 5 (2008), s. 146-150 $x 0015-5500
856    41
$u https://fb.cuni.cz/Data/files/folia_biologica/volume_54_2008_5/FB2008A0025.pdf $y plný text volně přístupný
910    __
$a ABA008 $b A 970 $c 89 $y 9
990    __
$a 20090513150919 $b ABA008
991    __
$a 20090708085102 $b ABA008
999    __
$a ok $b bmc $g 651275 $s 504447
BAS    __
$a 3
BMC    __
$a 2008 $b 54 $c 5 $d 146-150 $i 0015-5500 $m Folia biologica (Praha) $x MED00011004
LZP    __
$a 2009-18/mkme

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...