-
Something wrong with this record ?
Portable uroflowmetric acquisition system
Wojciech Walendziuk, Adam Idzkowski, Marek Penhaker
Language English Country Czech Republic
Document type Chart
- MeSH
- Monitoring, Ambulatory methods instrumentation utilization MeSH
- Diagnostic Techniques, Urological instrumentation utilization MeSH
- Financing, Organized MeSH
- Prostatic Hyperplasia diagnosis physiopathology MeSH
- Humans MeSH
- Signal Processing, Computer-Assisted instrumentation MeSH
- Programming Languages MeSH
- Flowmeters utilization MeSH
- Statistics as Topic MeSH
- Urodynamics physiology MeSH
- Urologic Diseases diagnosis physiopathology MeSH
- Equipment and Supplies MeSH
- Check Tag
- Humans MeSH
- Publication type
- Chart MeSH
n this paper an original portable urofl owmeter has been presented. Th e device draws a fl ow chart and measures the parameters of urine fl ow. It is used in urological surgeries as an assistance in diagnosis of lower urinary track diseases e.g. Benign Prostatic Hyperplasia (BPH). A block diagram of the device and the way of data acquisition have been described. An uncertainty of fl ow chart has been calculated. An example fl ow chart has been discussed.
The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
Bibliography, etc.Lit.: 5
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07531358
- 003
- CZ-PrNML
- 005
- 20111210152036.0
- 008
- 091019s2008 xr e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Walendziuk, Wojciech
- 245 10
- $a Portable uroflowmetric acquisition system / $c Wojciech Walendziuk, Adam Idzkowski, Marek Penhaker
- 314 __
- $a Bialystok Technical University, Faculty of Electrical Engineering, Poland
- 500 __
- $a The third Biomedical Engineering Conference of Young Biomedical Engineers and Researchers, July 8-10, 2008 Ostrava, The Czech Republic
- 504 __
- $a Lit.: 5
- 520 9_
- $a n this paper an original portable urofl owmeter has been presented. Th e device draws a fl ow chart and measures the parameters of urine fl ow. It is used in urological surgeries as an assistance in diagnosis of lower urinary track diseases e.g. Benign Prostatic Hyperplasia (BPH). A block diagram of the device and the way of data acquisition have been described. An uncertainty of fl ow chart has been calculated. An example fl ow chart has been discussed.
- 650 _2
- $a diagnostické techniky urologické $x přístrojové vybavení $x využití $7 D003950
- 650 _2
- $a urodynamika $x fyziologie $7 D014563
- 650 _2
- $a průtokoměry $x využití $7 D045268
- 650 _2
- $a urologické nemoci $x diagnóza $x patofyziologie $7 D014570
- 650 _2
- $a hyperplazie prostaty $x diagnóza $x patofyziologie $7 D011470
- 650 _2
- $a zdravotnické prostředky $7 D004864
- 650 _2
- $a počítačové zpracování signálu $x přístrojové vybavení $7 D012815
- 650 _2
- $a ambulantní monitorování $x metody $x přístrojové vybavení $x využití $7 D018670
- 650 _2
- $a statistika jako téma $7 D013223
- 650 _2
- $a programovací jazyk $7 D011381
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a lidé $7 D006801
- 655 _2
- $a grafy a diagramy $7 D020468
- 700 1_
- $a Idzkowski, Adam
- 700 1_
- $a Penhaker, Marek, $d 1972- $7 mzk2004246505
- 773 0_
- $w MED00011033 $t Lékař a technika $g Roč. 38, č. 2 (2008), s. 134-137 $x 0301-5491
- 856 41
- $u http://www.sbmili.cz/journal/LaT_2008_2.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1367 $c 1071 b $y 9
- 990 __
- $a 20091016134404 $b ABA008
- 991 __
- $a 20091029152754 $b ABA008
- 999 __
- $a ok $b bmc $g 690212 $s 552097
- BAS __
- $a 3
- BMC __
- $a 2008 $b 38 $c 2 $d 134-137 $i 0301-5491 $m Lékař a technika $x MED00011033
- LZP __
- $a 2009-54/vtal