Matrix-less laser desorption/ionisation mass spectrometry of polyphenols in red wine
Z. Spáčil, M. Shariatgorji, N. Amini, P. Solich, L.L. Ilag
Jazyk angličtina Země Velká Británie
Typ dokumentu hodnotící studie, práce podpořená grantem
PubMed
19444859
DOI
10.1002/rcm.4062
Knihovny.cz E-zdroje
- MeSH
- fenoly chemie MeSH
- flavonoidy chemie MeSH
- senzitivita a specificita MeSH
- spektrometrie hmotnostní - ionizace laserem za účasti matrice metody MeSH
- víno analýza MeSH
- Publikační typ
- hodnotící studie MeSH
- práce podpořená grantem MeSH
Matrix-assisted laser desorption/ionisation (MALDI) of small molecules is challenging and in most cases impossible due to interferences from matrix ions precluding analysis of molecules <300-500 Da. A common matrix such as ferulic acid belongs to an important class of compounds associated with antioxidant activity. If the shared phenolic structure is related to the propensity as an active MALDI matrix then it follows that direct laser desorption/ionisation should be possible for polyphenols. Indeed matrix-less laser desorption/ionisation mass spectrometry is achieved whereby the analyte functions as a matrix and was used to monitor low molecular weight compounds in wine samples. Sensitivity ranging from 0.12-87 pmol/spot was achieved for eight phenolic acids (4-coumaric, 4-hydroxybenzoic, caffeic, ferulic, gallic, protocatechuic, syringic, vanillic) and 0.02 pmol/spot for trans-resveratrol. Additionally, 4-coumaric, 4-hydroxybenzoic, caffeic, ferulic, gallic, syringic, vanillic acids and trans-resveratrol were identified in wine samples using accurate mass measurements consistent with reported profiles based on liquid chromatography (LC)/MS. Minimal sample pre-treatment make the technique potentially appropriate for fingerprinting, screening and quality control of wine samples. Copyright (c) 2009 John Wiley & Sons, Ltd.
Citace poskytuje Crossref.org
- 000
- 02667naa 2200313 a 4500
- 001
- bmc11017113
- 003
- CZ-PrNML
- 005
- 20221005114816.0
- 008
- 110629s2009 xxk e eng||
- 009
- AR
- 024 7_
- $a 10.1002/rcm.4062 $2 doi
- 035 __
- $a (PubMed)19444859
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Spáčil, Zdeněk, $d 1982- $7 mzk2007411147
- 245 10
- $a Matrix-less laser desorption/ionisation mass spectrometry of polyphenols in red wine / $c Z. Spáčil, M. Shariatgorji, N. Amini, P. Solich, L.L. Ilag
- 314 __
- $a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University in Prague, Heyrovskeho 1203, 500 05 Hradec Kralove, Czech Republic.
- 520 9_
- $a Matrix-assisted laser desorption/ionisation (MALDI) of small molecules is challenging and in most cases impossible due to interferences from matrix ions precluding analysis of molecules <300-500 Da. A common matrix such as ferulic acid belongs to an important class of compounds associated with antioxidant activity. If the shared phenolic structure is related to the propensity as an active MALDI matrix then it follows that direct laser desorption/ionisation should be possible for polyphenols. Indeed matrix-less laser desorption/ionisation mass spectrometry is achieved whereby the analyte functions as a matrix and was used to monitor low molecular weight compounds in wine samples. Sensitivity ranging from 0.12-87 pmol/spot was achieved for eight phenolic acids (4-coumaric, 4-hydroxybenzoic, caffeic, ferulic, gallic, protocatechuic, syringic, vanillic) and 0.02 pmol/spot for trans-resveratrol. Additionally, 4-coumaric, 4-hydroxybenzoic, caffeic, ferulic, gallic, syringic, vanillic acids and trans-resveratrol were identified in wine samples using accurate mass measurements consistent with reported profiles based on liquid chromatography (LC)/MS. Minimal sample pre-treatment make the technique potentially appropriate for fingerprinting, screening and quality control of wine samples. Copyright (c) 2009 John Wiley & Sons, Ltd.
- 590 __
- $a bohemika - dle Pubmed
- 650 _2
- $a flavonoidy $x chemie $7 D005419
- 650 _2
- $a fenoly $x chemie $7 D010636
- 650 _2
- $a senzitivita a specificita $7 D012680
- 650 _2
- $a spektrometrie hmotnostní - ionizace laserem za účasti matrice $x metody $7 D019032
- 650 _2
- $a víno $x analýza $7 D014920
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Shariatgorji, Mohammadreza
- 700 1_
- $a Amini, Nahid $7 gn_A_00005600
- 700 1_
- $a Solich, Petr, $d 1955- $7 jo2007285395
- 700 1_
- $a Ilag, Leopold L.
- 773 0_
- $t Rapid Communications in Mass Spectrometry $w MED00004050 $g Roč. 23, č. 12 (2009), s. 1834-1840
- 910 __
- $a ABA008 $b x $y 2 $z 0
- 990 __
- $a 20110720101553 $b ABA008
- 991 __
- $a 20221005114812 $b ABA008
- 999 __
- $a ok $b bmc $g 864167 $s 726908
- BAS __
- $a 3
- BMC __
- $a 2009 $x MED00004050 $b 23 $c 12 $d 1834-1840 $m Rapid communications in mass spectrometry $n Rapid Commun Mass Spectrom
- LZP __
- $a 2011-3B09/BBjvme