Limitations of macroscopic fluorescence imaging for the estimation of tumour growth in an orthotopic glioma mouse model
M. Hilšer, J. Trylčová, P. Bušek, A. Šedo
Jazyk angličtina Země Česko
Typ dokumentu práce podpořená grantem
NLK
Free Medical Journals
od 2000
Freely Accessible Science Journals
od 2000
ProQuest Central
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2000
- MeSH
- diagnostické zobrazování metody metody MeSH
- fluorescence MeSH
- gliom diagnóza MeSH
- lidé MeSH
- modely nemocí na zvířatech MeSH
- myši MeSH
- nádorové buněčné linie MeSH
- optická tomografie metody MeSH
- transplantace nádorů MeSH
- zvířata MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- práce podpořená grantem MeSH
Imaging methods based on light detection are being increasingly used for the non-invasive assessment of tumour growth in animal models. In contrast with bioluminescence imaging, there are no studies assessing the use of macroscopic fluorescence imaging for the longitudinal monitoring of tumour growth in an orthotopic glioma mouse model. Glioma cells expressing the red-shifted fluorescent protein mKate2 were orthotopically implanted to NOD-rag mice and the tumour size estimated by macroscopic fluorescence imaging was compared to the tumour volume determined morphometrically. There was no significant correlation between the data obtained by non-invasive macroscopic fluorescence imaging and post mortem morphometry. In addition, the fluorescence imaging failed to detect a morphometrically verified difference in tumour volume between animals with tumours expressing a potential tumour suppressor gene and controls. The fluorescence signal was affected by the spatial pattern of tumour growth and substantially attenuated by the interfering brain tissue. Our results indicate that the fluorescence signal emitted by glioma cells reflected not only the tumour mass, but also its spatial distribution. Macroscopic planar FLI in an epi-illumination mode and a conventional source of excitation light therefore appears to be more suitable for semi-quantitative assessment of the tumour growth especially in the case of superficially located tumours rather than for precise volume estimation of the xenografts located deep within the brain tissue.
Literatura
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12022874
- 003
- CZ-PrNML
- 005
- 20130123112306.0
- 007
- ta
- 008
- 120807s2012 xr do f 000 0eng||
- 009
- AR
- 040 __
- $a ABA008 $d ABA008 $e AACR2 $b cze
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Hilšer, Marek. $7 xx0208340 $u Institute of Biochemistry and Experimental Oncology, First Faculty of Medicine, Charles University in Prague
- 245 10
- $a Limitations of macroscopic fluorescence imaging for the estimation of tumour growth in an orthotopic glioma mouse model / $c M. Hilšer, J. Trylčová, P. Bušek, A. Šedo
- 504 __
- $a Literatura $b 21
- 520 9_
- $a Imaging methods based on light detection are being increasingly used for the non-invasive assessment of tumour growth in animal models. In contrast with bioluminescence imaging, there are no studies assessing the use of macroscopic fluorescence imaging for the longitudinal monitoring of tumour growth in an orthotopic glioma mouse model. Glioma cells expressing the red-shifted fluorescent protein mKate2 were orthotopically implanted to NOD-rag mice and the tumour size estimated by macroscopic fluorescence imaging was compared to the tumour volume determined morphometrically. There was no significant correlation between the data obtained by non-invasive macroscopic fluorescence imaging and post mortem morphometry. In addition, the fluorescence imaging failed to detect a morphometrically verified difference in tumour volume between animals with tumours expressing a potential tumour suppressor gene and controls. The fluorescence signal was affected by the spatial pattern of tumour growth and substantially attenuated by the interfering brain tissue. Our results indicate that the fluorescence signal emitted by glioma cells reflected not only the tumour mass, but also its spatial distribution. Macroscopic planar FLI in an epi-illumination mode and a conventional source of excitation light therefore appears to be more suitable for semi-quantitative assessment of the tumour growth especially in the case of superficially located tumours rather than for precise volume estimation of the xenografts located deep within the brain tissue.
- 650 02
- $a zvířata $7 D000818
- 650 02
- $a nádorové buněčné linie $7 D045744
- 650 02
- $a diagnostické zobrazování $x metody $7 D003952
- 650 02
- $a modely nemocí na zvířatech $7 D004195
- 650 02
- $a fluorescence $7 D005453
- 650 02
- $a gliom $x diagnóza $7 D005910
- 650 02
- $a lidé $7 D006801
- 650 02
- $a mužské pohlaví $7 D008297
- 650 02
- $a myši $7 D051379
- 650 02
- $a transplantace nádorů $7 D009368
- 650 _2
- $a diagnostické zobrazování $x metody $7 D003952
- 650 _2
- $a optická tomografie $x metody $7 D041622
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Trylčová, Jana. $7 _AN068677 $u Institute of Biochemistry and Experimental Oncology, First Faculty of Medicine, Charles University in Prague
- 700 1_
- $a Bušek, Petr $7 xx0094315 $u Institute of Biochemistry and Experimental Oncology, First Faculty of Medicine, Charles University in Prague
- 700 1_
- $a Šedo, Aleksi, $d 1967- $7 jn20000605245 $u Institute of Biochemistry and Experimental Oncology, First Faculty of Medicine, Charles University in Prague
- 773 0_
- $t Folia biologica $x 0015-5500 $g Roč. 58, č. 3 (2012), s. 128-133 $w MED00011004
- 856 41
- $u https://fb.cuni.cz/file/5647/FB2012A0020.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 970 $c 89 $y 3
- 990 __
- $a 20120806162845 $b ABA008
- 991 __
- $a 20130123112425 $b ABA008
- 999 __
- $a ok $b bmc $g 944795 $s 780175
- BAS __
- $a 3
- BMC __
- $a 2012 $b 58 $c 3 $d 128-133 $i 0015-5500 $m Folia biologica (Praha) $n Folia biol. (Praha) $x MED00011004
- LZP __
- $a 2012-14/mkme