• Je něco špatně v tomto záznamu ?

Separation of PCBs by liquid chromatography on reversed phase sub-2-micron particle columns

J. Olsovská, Z. Kresinová, M. Flieger, T. Cajthaml

. 2010 ; 80 (5) : 1849-1855.

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12025190

A new ultra high-performance liquid chromatography method with UV detection was examined for detection and separation of polychlorinated biphenyls. This included optimization of separation conditions for two model mixtures containing seven and fifteen most relevant congeners, comparison of three types of reversed phase sub-2-micron particle sized columns and assessment of system suitability under the optimized conditions. Calibration curves determined in the range from 0.5 to 50.0 microg/mL exhibited correlation coefficients ranging from 0.997 to 0.999. Lower limits of detection ranged from 0.1 to 0.5 ppm. The most efficient Grace C18 column filled with 1.5 microm particles was then tested to separate the complex commercial mixture Delor 103, where the elution order was confirmed by GC-MS. 13 individual congeners were separated and some of the other co-eluting congeners could be resolved using another separation dimension performed with a mass spectrometry detector. The developed method could be directly applied to the separation of less complex mixtures in aqueous sample matrixes, which are used in general for enzyme degradation studies.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12025190
003      
CZ-PrNML
005      
20130315122756.0
007      
ta
008      
120816s2010 enk f 000 0#eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2009.10.033 $2 doi
035    __
$a (PubMed)20152422
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Olšovská, Jana $7 xx0096915 $u Institute of Microbiology, Academy of Sciences of the Czech Republic, vvi, Vídenská 1083, CZ-142 20 Prague 4, Czech Republic.
245    10
$a Separation of PCBs by liquid chromatography on reversed phase sub-2-micron particle columns / $c J. Olsovská, Z. Kresinová, M. Flieger, T. Cajthaml
520    9_
$a A new ultra high-performance liquid chromatography method with UV detection was examined for detection and separation of polychlorinated biphenyls. This included optimization of separation conditions for two model mixtures containing seven and fifteen most relevant congeners, comparison of three types of reversed phase sub-2-micron particle sized columns and assessment of system suitability under the optimized conditions. Calibration curves determined in the range from 0.5 to 50.0 microg/mL exhibited correlation coefficients ranging from 0.997 to 0.999. Lower limits of detection ranged from 0.1 to 0.5 ppm. The most efficient Grace C18 column filled with 1.5 microm particles was then tested to separate the complex commercial mixture Delor 103, where the elution order was confirmed by GC-MS. 13 individual congeners were separated and some of the other co-eluting congeners could be resolved using another separation dimension performed with a mass spectrometry detector. The developed method could be directly applied to the separation of less complex mixtures in aqueous sample matrixes, which are used in general for enzyme degradation studies.
650    _2
$a kalibrace $7 D002138
650    _2
$a vysokoúčinná kapalinová chromatografie $x přístrojové vybavení $x metody $7 D002851
650    _2
$a plynová chromatografie s hmotnostně spektrometrickou detekcí $7 D008401
650    _2
$a limita detekce $7 D057230
650    _2
$a polychlorované bifenyly $x izolace a purifikace $7 D011078
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1#
$a Hrsinová Křesinová, Zdena. $7 xx0203947
700    1_
$a Flieger, Miroslav, $d 1948- $7 uk2007300491
700    1_
$a Cajthaml, Tomáš, $d 1975- $7 xx0063848
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 80, č. 5 (2010), s. 1849-1855
856    41
$u https://pubmed.ncbi.nlm.nih.gov/20152422 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120816 $b ABA008
991    __
$a 20130315123013 $b ABA008
999    __
$a ok $b bmc $g 947232 $s 782536
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2010 $b 80 $c 5 $d 1849-1855 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20120816/10/02

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...