-
Je něco špatně v tomto záznamu ?
Raman spectra of pure biomolecules obtained using a handheld instrument under cold high-altitude conditions
J. Jehlicka, P. Vandenabeele, HG. Edwards, A. Culka, T. Capoun,
Jazyk angličtina Země Německo
Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem
NLK
ProQuest Central
od 2001-01-01 do 2010-12-31
Medline Complete (EBSCOhost)
od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 2001-01-01 do 2010-12-31
- MeSH
- aminokyseliny analýza MeSH
- exobiologie přístrojové vybavení metody MeSH
- kyseliny karboxylové analýza MeSH
- limita detekce MeSH
- nadmořská výška MeSH
- nízká teplota MeSH
- Ramanova spektroskopie metody MeSH
- sacharidy analýza MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
A handheld Raman spectrometer (Ahura First Defender) was tested for the unambiguous identification of biomolecules (pure amino acids, carboxylic acids, saccharides and trehalose) in the solid state under outdoor conditions (including moderate climate conditions as well as cold temperatures and high altitudes). The biomolecules investigated represent important objects of interest for future exobiological missions. Repetitive measurements carried out under identical instrumental setups confirmed the excellent reliability of the Raman spectrometer. Raman bands are found at correct wavenumbers +/-3 cm(-1) compared with reference values. This testing represents the first step in a series of studies. In a preliminary, challenging investigation to determine the detection limit for glycine dispersed in a powdered gypsum matrix, 10% was the lowest content confirmed unambiguously. Clearly there is a need to investigate further the detection limits of Raman spectroscopic analyses of biomolecules in more complex samples, to demonstrate the usefulness or disqualify the use of this technique for more realistic outdoor situations, such as eventual future missions to Mars.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12026370
- 003
- CZ-PrNML
- 005
- 20121206110520.0
- 007
- ta
- 008
- 120817e20100602gw f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-010-3849-7 $2 doi
- 035 __
- $a (PubMed)20517597
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Jehlicka, Jan $u Institute of Geochemistry, Mineralogy and Mineral Resources, Charles University in Prague, Albertov 6, I2843 Prague 2, Czech Republic. jehlicka@natur.cuni.cz
- 245 10
- $a Raman spectra of pure biomolecules obtained using a handheld instrument under cold high-altitude conditions / $c J. Jehlicka, P. Vandenabeele, HG. Edwards, A. Culka, T. Capoun,
- 520 9_
- $a A handheld Raman spectrometer (Ahura First Defender) was tested for the unambiguous identification of biomolecules (pure amino acids, carboxylic acids, saccharides and trehalose) in the solid state under outdoor conditions (including moderate climate conditions as well as cold temperatures and high altitudes). The biomolecules investigated represent important objects of interest for future exobiological missions. Repetitive measurements carried out under identical instrumental setups confirmed the excellent reliability of the Raman spectrometer. Raman bands are found at correct wavenumbers +/-3 cm(-1) compared with reference values. This testing represents the first step in a series of studies. In a preliminary, challenging investigation to determine the detection limit for glycine dispersed in a powdered gypsum matrix, 10% was the lowest content confirmed unambiguously. Clearly there is a need to investigate further the detection limits of Raman spectroscopic analyses of biomolecules in more complex samples, to demonstrate the usefulness or disqualify the use of this technique for more realistic outdoor situations, such as eventual future missions to Mars.
- 650 _2
- $a nadmořská výška $7 D000531
- 650 _2
- $a aminokyseliny $x analýza $7 D000596
- 650 _2
- $a sacharidy $x analýza $7 D002241
- 650 _2
- $a kyseliny karboxylové $x analýza $7 D002264
- 650 _2
- $a nízká teplota $7 D003080
- 650 _2
- $a exobiologie $x přístrojové vybavení $x metody $7 D018559
- 650 _2
- $a limita detekce $7 D057230
- 650 _2
- $a Ramanova spektroskopie $x metody $7 D013059
- 655 _2
- $a hodnotící studie $7 D023362
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Vandenabeele, Peter
- 700 1_
- $a Edwards, Howell G M
- 700 1_
- $a Culka, Adam
- 700 1_
- $a Capoun, Tomás
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 397, č. 7 (20100602), s. 2753-60
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/20517597 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20121206110553 $b ABA008
- 999 __
- $a ok $b bmc $g 948412 $s 783716
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2010 $b 397 $c 7 $d 2753-60 $e 20100602 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- LZP __
- $a Pubmed-20120817/10/04