-
Something wrong with this record ?
Assessing the applicability of the earth impedance method for in situ studies of tree root systems
J. Urban, R. Bequet, R. Mainiero,
Language English Country England, Great Britain
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
Free Medical Journals
from 1996 to 1 year ago
Open Access Digital Library
from 1996-01-01
PubMed
21273337
DOI
10.1093/jxb/erq370
Knihovny.cz E-resources
- MeSH
- Algorithms MeSH
- Biometry MeSH
- Cycadopsida MeSH
- Electric Impedance MeSH
- Plant Roots anatomy & histology physiology MeSH
- Magnoliopsida MeSH
- Fertilizers MeSH
- Soil MeSH
- Seasons MeSH
- Trees anatomy & histology physiology MeSH
- Xylem physiology MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Several electrical methods have been introduced as non-invasive techniques to overcome the limited accessibility to root systems. Among them, the earth impedance method (EIM) represents the most recent development. Applying an electrical field between a cormus and the rooted soil, the EIM measures the absorptive root surface area (ARSA) from grounding resistance patterns. Allometric relationships suggested that this method was a valuable tool. Crucial assumptions for the applicability of the EIM, however, have not been tested experimentally. Focusing on tree root systems, the present study assesses the applicability of the EIM. Six hypotheses, deduced from the EIM approach, were tested in several experiments and the results were compared with conventional methods. None of the hypotheses could be verified and the results allow two major conclusions. First, in terms of an analogue electrical circuit, a tree-root-soil continuum appears as a serial circuit with xylem and soil resistance being the dominant components. Allometric variation in contact resistance, with the latter being the proxy for root surface area, are thus overruled by the spatial and seasonal variation of soil and xylem resistances. Second, in a tree-root-soil continuum, distal roots conduct only a negligible portion of the electric charge. Most of charge carriers leave the root system in the proximal parts of the root-soil interface.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12027853
- 003
- CZ-PrNML
- 005
- 20121207114921.0
- 007
- ta
- 008
- 120817e20110127enk f 000 0#eng||
- 009
- AR
- 024 7_
- $a 10.1093/jxb/erq370 $2 doi
- 035 __
- $a (PubMed)21273337
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Urban, Josef $u Department of Forest Botany, Faculty of Forestry and Wood Technology, Mendel University in Brno, Zemědělská 3, 61300 Brno, Czech Republic. Josef.urban@email.cz
- 245 10
- $a Assessing the applicability of the earth impedance method for in situ studies of tree root systems / $c J. Urban, R. Bequet, R. Mainiero,
- 520 9_
- $a Several electrical methods have been introduced as non-invasive techniques to overcome the limited accessibility to root systems. Among them, the earth impedance method (EIM) represents the most recent development. Applying an electrical field between a cormus and the rooted soil, the EIM measures the absorptive root surface area (ARSA) from grounding resistance patterns. Allometric relationships suggested that this method was a valuable tool. Crucial assumptions for the applicability of the EIM, however, have not been tested experimentally. Focusing on tree root systems, the present study assesses the applicability of the EIM. Six hypotheses, deduced from the EIM approach, were tested in several experiments and the results were compared with conventional methods. None of the hypotheses could be verified and the results allow two major conclusions. First, in terms of an analogue electrical circuit, a tree-root-soil continuum appears as a serial circuit with xylem and soil resistance being the dominant components. Allometric variation in contact resistance, with the latter being the proxy for root surface area, are thus overruled by the spatial and seasonal variation of soil and xylem resistances. Second, in a tree-root-soil continuum, distal roots conduct only a negligible portion of the electric charge. Most of charge carriers leave the root system in the proximal parts of the root-soil interface.
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a Magnoliopsida $7 D019684
- 650 _2
- $a biometrie $7 D001699
- 650 _2
- $a elektrická impedance $7 D017097
- 650 _2
- $a průmyslová hnojiva $7 D005308
- 650 _2
- $a cykasy $7 D032462
- 650 _2
- $a kořeny rostlin $x anatomie a histologie $x fyziologie $7 D018517
- 650 _2
- $a roční období $7 D012621
- 650 _2
- $a půda $7 D012987
- 650 _2
- $a stromy $x anatomie a histologie $x fyziologie $7 D014197
- 650 _2
- $a xylém $x fyziologie $7 D052584
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Bequet, Raphael
- 700 1_
- $a Mainiero, Raphael
- 773 0_
- $w MED00006559 $t Journal of experimental botany $x 1460-2431 $g Roč. 62, č. 6 (20110127), s. 1857-69
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21273337 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m
- 990 __
- $a 20120817 $b ABA008
- 991 __
- $a 20121207114955 $b ABA008
- 999 __
- $a ok $b bmc $g 949895 $s 785199
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 62 $c 6 $d 1857-69 $e 20110127 $i 1460-2431 $m Journal of Experimental Botany $n J Exp Bot $x MED00006559
- LZP __
- $a Pubmed-20120817/11/03