Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Czech primary radon measurement equipment

I. Burian, P. Otahal, J. Vosahlik, E. Pilecka,

. 2011 ; 145 (2-3) : 333-6. [pub] 20110411

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc12028367

The Authorized Metrological Centre (AMS) working by SUJCHBO (National Institute for Nuclear, Chemical and Biological Protection) ensures for the Czech Republic the metrological traceability for devices that measure the radon concentration and the energy equivalent radon concentration connected with the radon decay products (RnDP). The evaluation and the calibration of measuring devices for radon and RnDP require the stable conditions (first of all radon and the RnDP concentrations). The new AMS radon-aerosol chamber in Kamenná consists of the walk-in testing chamber with a volume of 10 m(3) and of the handling box with a volume of 0.3 m(3). The design of the chamber allows measurement and a control of environmental parameters such as the temperature, the pressure of air inside and outside of the chamber, the relative humidity of air, the concentration and the size distribution of aerosol particles and the air velocity.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc12028367
003      
CZ-PrNML
005      
20121210112457.0
007      
ta
008      
120817e20110411enk f 000 0#eng||
009      
AR
024    7_
$a 10.1093/rpd/ncr041 $2 doi
035    __
$a (PubMed)21482617
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Burian, Ivo $u National Institute for Nuclear, Chemical and Biological Protection, Kamenná 71, 262 31 Milín, Czech Republic. burian@sujchbo.cz
245    10
$a Czech primary radon measurement equipment / $c I. Burian, P. Otahal, J. Vosahlik, E. Pilecka,
520    9_
$a The Authorized Metrological Centre (AMS) working by SUJCHBO (National Institute for Nuclear, Chemical and Biological Protection) ensures for the Czech Republic the metrological traceability for devices that measure the radon concentration and the energy equivalent radon concentration connected with the radon decay products (RnDP). The evaluation and the calibration of measuring devices for radon and RnDP require the stable conditions (first of all radon and the RnDP concentrations). The new AMS radon-aerosol chamber in Kamenná consists of the walk-in testing chamber with a volume of 10 m(3) and of the handling box with a volume of 0.3 m(3). The design of the chamber allows measurement and a control of environmental parameters such as the temperature, the pressure of air inside and outside of the chamber, the relative humidity of air, the concentration and the size distribution of aerosol particles and the air velocity.
650    _2
$a radioaktivní látky znečišťující vzduch $x analýza $7 D000396
650    _2
$a kalibrace $7 D002138
650    _2
$a lidé $7 D006801
650    _2
$a monitorování radiace $x přístrojové vybavení $7 D011834
650    _2
$a radon $x analýza $7 D011886
651    _2
$a Česká republika $7 D018153
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Otahal, Petr
700    1_
$a Vosahlik, Josef
700    1_
$a Pilecka, Eliska
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 145, č. 2-3 (20110411), s. 333-6
856    41
$u https://pubmed.ncbi.nlm.nih.gov/21482617 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y m
990    __
$a 20120817 $b ABA008
991    __
$a 20121210112533 $b ABA008
999    __
$a ok $b bmc $g 950409 $s 785713
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2011 $b 145 $c 2-3 $d 333-6 $e 20110411 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20120817/11/04

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...