Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Capillary electrophoresis as a verification tool for immunochemical drug screening

J. Znaleziona, J. Petr, V. Maier, R. Knob, J. Horakova, D. Smetanova, J. Sevcik

. 2007 ; 151 (1) : 31-36.

Jazyk angličtina Země Česko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13003644

UNLABELLED: BACKGROUND: The aim of this work was to develop a simple capillary electrophoretic method as the verification and confirmation tool in the screening analysis for amphetamines, opiates, benzodiazepines and cocaine and their metabolites for toxicological applications. METHODS: 50 mM phosphate Tris pH 2.0 with 30% (v/v) of methanol was used as a background electrolyte that enabled fast separation of drugs and their metabolites in saliva and urine. Verification of the data from the electrophoretic method was done by High Performance Thin Layer Chromatography (HPTLC) and the immunochemical screening test QuikScreen. RESULTS: The experimental conditions of the Capillary Electrophoresis (CE) were partially optimized (mainly the influence of concentration and types of additives, e.g. cyclodextrines, organic solvents) and validated; the method was used for analysing samples from drug abusers. CONCLUSIONS: The non-instrumental, immunoassay tests could only confirm qualitative addictions and are mainly employed when the emergency detection of drugs is needed. For quantitative analysis and verification of obtained results the confirmation step is strongly recommended. The simple screening capillary zone electrophoresis method allows recognition of the most abused drugs. The agreement of the results from CE, HPTLC and QuikScreen test was more than 95%.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13003644
003      
CZ-PrNML
005      
20130221111802.0
007      
ta
008      
130128s2007 xr d f 000 0|eng||
009      
AR
024    7_
$a 10.5507/bp.2007.005 $2 doi
035    __
$a (PubMed)17690736
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xr
100    1_
$a Znaleziona, Joanna $7 xx0099620 $u Department of Analytical Chemistry, Faculty of Science, Palacky University, Olomouc
245    10
$a Capillary electrophoresis as a verification tool for immunochemical drug screening / $c J. Znaleziona, J. Petr, V. Maier, R. Knob, J. Horakova, D. Smetanova, J. Sevcik
520    9_
$a UNLABELLED: BACKGROUND: The aim of this work was to develop a simple capillary electrophoretic method as the verification and confirmation tool in the screening analysis for amphetamines, opiates, benzodiazepines and cocaine and their metabolites for toxicological applications. METHODS: 50 mM phosphate Tris pH 2.0 with 30% (v/v) of methanol was used as a background electrolyte that enabled fast separation of drugs and their metabolites in saliva and urine. Verification of the data from the electrophoretic method was done by High Performance Thin Layer Chromatography (HPTLC) and the immunochemical screening test QuikScreen. RESULTS: The experimental conditions of the Capillary Electrophoresis (CE) were partially optimized (mainly the influence of concentration and types of additives, e.g. cyclodextrines, organic solvents) and validated; the method was used for analysing samples from drug abusers. CONCLUSIONS: The non-instrumental, immunoassay tests could only confirm qualitative addictions and are mainly employed when the emergency detection of drugs is needed. For quantitative analysis and verification of obtained results the confirmation step is strongly recommended. The simple screening capillary zone electrophoresis method allows recognition of the most abused drugs. The agreement of the results from CE, HPTLC and QuikScreen test was more than 95%.
650    _2
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    _2
$a elektroforéza kapilární $7 D019075
650    _2
$a lidé $7 D006801
650    _2
$a imunologické testy $7 D007159
650    _2
$a odhalování abúzu drog $7 D015813
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Petr, Jan $7 mzk2007411125 $u Department of Analytical Chemistry, Faculty of Science, Palacky University, Olomouc
700    1_
$a Maier, Vítězslav, $d 1979- $7 mzk2006356017 $u Department of Analytical Chemistry, Faculty of Science, Palacky University, Olomouc
700    1_
$a Knob, Radim, $d 1985- $7 xx0099480 $u Department of Analytical Chemistry, Faculty of Science, Palacky University, Olomouc
700    1_
$a Horáková, Jana. $7 _AN030311 $u Department of Analytical Chemistry, Faculty of Science, Palacky University, Olomouc
700    1_
$a Smetanová, Dana. $7 _AN071372 $u Department of Analytical Chemistry, Faculty of Science, Palacky University, Olomouc
700    1_
$a Ševčík, Juraj, $d 1964- $7 ola2002157977 $u Department of Analytical Chemistry, Faculty of Science, Palacky University, Olomouc
773    0_
$w MED00012606 $t Biomedical papers of the Medical Faculty of the University Palacký, Olomouc, Czech Republic $x 1213-8118 $g Roč. 151, č. 1 (2007), s. 31-36
910    __
$a ABA008 $b A 1502 $c sign $y 3 $z 0
990    __
$a 20130128 $b ABA008
991    __
$a 20130221111955 $b ABA008
999    __
$a ok $b bmc $g 966300 $s 801839
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2007 $b 151 $c 1 $d 31-36 $i 1213-8118 $m Biomedical papers of the Medical Faculty of the University Palacký, Olomouc Czech Republic $n Biomed. Pap. Fac. Med. Palacký Univ. Olomouc Czech Repub. (Print) $x MED00012606
LZP    __
$b NLK111 $a Pubmed-20130128

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...