-
Something wrong with this record ?
The retinal nerve fibre layer thickness in glaucomatous hydrophthalmic eyes assessed by scanning laser polarimetry with variable corneal compensation in comparison with age-matched healthy children
M. Hložánek, J. Ošmera, P. Ležatková, P. Sedláčková, A. Filouš,
Language English Country England, Great Britain
Document type Comparative Study, Journal Article, Research Support, Non-U.S. Gov't
NLK
Free Medical Journals
from 2008 to 1 year ago
Medline Complete (EBSCOhost)
from 2008-02-01 to 1 year ago
Wiley Online Library (archiv)
from 1997-01-01 to 2012-12-31
Wiley Free Content
from 2008 to 1 year ago
- MeSH
- Child MeSH
- Birefringence MeSH
- Hydrophthalmos pathology MeSH
- Humans MeSH
- Adolescent MeSH
- Optic Nerve Diseases pathology MeSH
- Nerve Fibers pathology MeSH
- Intraocular Pressure MeSH
- Cross-Sectional Studies MeSH
- Retinal Ganglion Cells pathology MeSH
- Cornea pathology MeSH
- Scanning Laser Polarimetry MeSH
- Check Tag
- Child MeSH
- Humans MeSH
- Adolescent MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Comparative Study MeSH
PURPOSE: To compare the thickness of the retinal nerve fibre layer (RNFL) in hydrophthalmic glaucomatous eyes in children with age-matched healthy controls using scanning laser polarimetry with variable corneal compensation (GDxVCC). METHODS: Twenty hydrophthalmic eyes of 20 patients with the mean age of 10.64 ± 3.02 years being treated for congenital or infantile glaucoma were included in the analysis. Evaluation of RNFL thickness measured by GDxVCC in standard Temporal-Superior-Nasal-Inferior-Temporal (TSNIT) parameters was performed. The results were compared to TSNIT values of an age-matched control group of 120 healthy children published recently as referential values. The correlation between horizontal corneal diameter and RNFL thickness in hydrophthalmic eyes was also investigated. RESULTS: The mean ± SD values in TSNIT Average, Superior Average, Inferior Average and TSNIT SD in hydrophthalmic eyes were 52.3 ± 11.4, 59.7 ± 17.1, 62.0 ± 15.6 and 20.0 ± 7.8 μm, respectively. All these values were significantly lower compared to referential TSNIT parameters of age-matched healthy eyes (p = 0.021, p = 0.001, p = 0.003 and p = 0.018, respectively). A substantial number of hydrophthalmic eyes laid below the level of 5% probability of normality in respective TSNIT parameters: 30% of the eyes in TSNIT average, 50% of the eyes in superior average, 30% of the eyes in inferior average and 45% of the eyes in TSNIT SD. No significant correlation between enlarged corneal diameter and RNFL thickness was found. CONCLUSIONS: The mean values of all standard TSNIT parameters assessed using GDxVCC in hydrophthalmic glaucomatous eyes in children were significantly lower in comparison with referential values of healthy age-matched children.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13012774
- 003
- CZ-PrNML
- 005
- 20130409094611.0
- 007
- ta
- 008
- 130404s2012 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/j.1755-3768.2011.02133.x $2 doi
- 035 __
- $a (PubMed)21418149
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Hložánek, Martin $u Department of Ophthalmology for Children and Adults, Charles University, 2nd Faculty of Medicine, FN Motol, Prague, Czech Republic.
- 245 14
- $a The retinal nerve fibre layer thickness in glaucomatous hydrophthalmic eyes assessed by scanning laser polarimetry with variable corneal compensation in comparison with age-matched healthy children / $c M. Hložánek, J. Ošmera, P. Ležatková, P. Sedláčková, A. Filouš,
- 520 9_
- $a PURPOSE: To compare the thickness of the retinal nerve fibre layer (RNFL) in hydrophthalmic glaucomatous eyes in children with age-matched healthy controls using scanning laser polarimetry with variable corneal compensation (GDxVCC). METHODS: Twenty hydrophthalmic eyes of 20 patients with the mean age of 10.64 ± 3.02 years being treated for congenital or infantile glaucoma were included in the analysis. Evaluation of RNFL thickness measured by GDxVCC in standard Temporal-Superior-Nasal-Inferior-Temporal (TSNIT) parameters was performed. The results were compared to TSNIT values of an age-matched control group of 120 healthy children published recently as referential values. The correlation between horizontal corneal diameter and RNFL thickness in hydrophthalmic eyes was also investigated. RESULTS: The mean ± SD values in TSNIT Average, Superior Average, Inferior Average and TSNIT SD in hydrophthalmic eyes were 52.3 ± 11.4, 59.7 ± 17.1, 62.0 ± 15.6 and 20.0 ± 7.8 μm, respectively. All these values were significantly lower compared to referential TSNIT parameters of age-matched healthy eyes (p = 0.021, p = 0.001, p = 0.003 and p = 0.018, respectively). A substantial number of hydrophthalmic eyes laid below the level of 5% probability of normality in respective TSNIT parameters: 30% of the eyes in TSNIT average, 50% of the eyes in superior average, 30% of the eyes in inferior average and 45% of the eyes in TSNIT SD. No significant correlation between enlarged corneal diameter and RNFL thickness was found. CONCLUSIONS: The mean values of all standard TSNIT parameters assessed using GDxVCC in hydrophthalmic glaucomatous eyes in children were significantly lower in comparison with referential values of healthy age-matched children.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a dvojitý lom $7 D001718
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a rohovka $x patologie $7 D003315
- 650 _2
- $a průřezové studie $7 D003430
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a hydroftalmus $x patologie $7 D006871
- 650 _2
- $a nitrooční tlak $7 D007429
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a nervová vlákna $x patologie $7 D009412
- 650 _2
- $a nemoci zrakového nervu $x patologie $7 D009901
- 650 _2
- $a retinální gangliové buňky $x patologie $7 D012165
- 650 _2
- $a skenovací laserová polarimetrie $7 D057109
- 655 _2
- $a srovnávací studie $7 D003160
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Ošmera, Jakub $u -
- 700 1_
- $a Ležatková, Pavlína $u -
- 700 1_
- $a Sedláčková, Petra $u -
- 700 1_
- $a Filouš, Aleš $u -
- 773 0_
- $w MED00179743 $t Acta ophthalmologica $x 1755-3768 $g Roč. 90, č. 8 (2012), s. 709-12
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/21418149 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130404 $b ABA008
- 991 __
- $a 20130409094839 $b ABA008
- 999 __
- $a ok $b bmc $g 975972 $s 811055
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 90 $c 8 $d 709-12 $i 1755-3768 $m Acta ophthalmologica $n Acta Ophthalmol $x MED00179743
- LZP __
- $a Pubmed-20130404