• Je něco špatně v tomto záznamu ?

Optimization of focused ultrasonic extraction of propellant components determined by gas chromatography/mass spectrometry

O. Fryš, P. Česla, P. Bajerová, M. Adam, K. Ventura,

. 2012 ; 99 () : 316-22.

Jazyk angličtina Země Nizozemsko

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc13016066

A method for focused ultrasonic extraction of nitroglycerin, triphenyl amine and acetyl tributyl citrate presented in double-base propellant samples following by the gas chromatography/mass spectrometry analysis was developed. A face-centered central composite design of the experiments and response surface modeling was used for optimization of the time, amplitude and sample amount. The dichloromethane was used as the extractant solvent. The optimal extraction conditions with respect to the maximum yield of the lowest abundant compound triphenyl amine were found at the 20 min extraction time, 35% amplitude of ultrasonic waves and 2.5 g of the propellant sample. The results obtained under optimal conditions were compared with the results achieved with validated Soxhlet extraction method, which is typically used for isolation and pre-concentration of compounds from the samples of explosives. The extraction yields for acetyl tributyl citrate using both extraction methods were comparable; however, the yield of ultrasonic extraction of nitroglycerin and triphenyl amine was lower than using Soxhlet extraction. The possible sources of different extraction yields are estimated and discussed.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc13016066
003      
CZ-PrNML
005      
20130424134930.0
007      
ta
008      
130424s2012 ne f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.talanta.2012.05.058 $2 doi
035    __
$a (PubMed)22967558
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Fryš, Ondřej $u University of Pardubice, Department of Analytical Chemistry, Faculty of Chemical Technology, Studentská 573, CZ-532 10 Pardubice, Czech Republic.
245    10
$a Optimization of focused ultrasonic extraction of propellant components determined by gas chromatography/mass spectrometry / $c O. Fryš, P. Česla, P. Bajerová, M. Adam, K. Ventura,
520    9_
$a A method for focused ultrasonic extraction of nitroglycerin, triphenyl amine and acetyl tributyl citrate presented in double-base propellant samples following by the gas chromatography/mass spectrometry analysis was developed. A face-centered central composite design of the experiments and response surface modeling was used for optimization of the time, amplitude and sample amount. The dichloromethane was used as the extractant solvent. The optimal extraction conditions with respect to the maximum yield of the lowest abundant compound triphenyl amine were found at the 20 min extraction time, 35% amplitude of ultrasonic waves and 2.5 g of the propellant sample. The results obtained under optimal conditions were compared with the results achieved with validated Soxhlet extraction method, which is typically used for isolation and pre-concentration of compounds from the samples of explosives. The extraction yields for acetyl tributyl citrate using both extraction methods were comparable; however, the yield of ultrasonic extraction of nitroglycerin and triphenyl amine was lower than using Soxhlet extraction. The possible sources of different extraction yields are estimated and discussed.
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Česla, Petr $u -
700    1_
$a Bajerová, Petra $u -
700    1_
$a Adam, Martin $u - $7 xx0064600
700    1_
$a Ventura, Karel $u -
773    0_
$w MED00004484 $t Talanta $x 1873-3573 $g Roč. 99(2012), s. 316-22
856    41
$u https://pubmed.ncbi.nlm.nih.gov/22967558 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20130424 $b ABA008
991    __
$a 20130424135218 $b ABA008
999    __
$a ind $b bmc $g 979267 $s 814387
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2012 $b 99 $d 316-22 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
LZP    __
$a Pubmed-20130424

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...