-
Je něco špatně v tomto záznamu ?
Optimization of focused ultrasonic extraction of propellant components determined by gas chromatography/mass spectrometry
O. Fryš, P. Česla, P. Bajerová, M. Adam, K. Ventura,
Jazyk angličtina Země Nizozemsko
Typ dokumentu časopisecké články, práce podpořená grantem
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A method for focused ultrasonic extraction of nitroglycerin, triphenyl amine and acetyl tributyl citrate presented in double-base propellant samples following by the gas chromatography/mass spectrometry analysis was developed. A face-centered central composite design of the experiments and response surface modeling was used for optimization of the time, amplitude and sample amount. The dichloromethane was used as the extractant solvent. The optimal extraction conditions with respect to the maximum yield of the lowest abundant compound triphenyl amine were found at the 20 min extraction time, 35% amplitude of ultrasonic waves and 2.5 g of the propellant sample. The results obtained under optimal conditions were compared with the results achieved with validated Soxhlet extraction method, which is typically used for isolation and pre-concentration of compounds from the samples of explosives. The extraction yields for acetyl tributyl citrate using both extraction methods were comparable; however, the yield of ultrasonic extraction of nitroglycerin and triphenyl amine was lower than using Soxhlet extraction. The possible sources of different extraction yields are estimated and discussed.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc13016066
- 003
- CZ-PrNML
- 005
- 20130424134930.0
- 007
- ta
- 008
- 130424s2012 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.talanta.2012.05.058 $2 doi
- 035 __
- $a (PubMed)22967558
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Fryš, Ondřej $u University of Pardubice, Department of Analytical Chemistry, Faculty of Chemical Technology, Studentská 573, CZ-532 10 Pardubice, Czech Republic.
- 245 10
- $a Optimization of focused ultrasonic extraction of propellant components determined by gas chromatography/mass spectrometry / $c O. Fryš, P. Česla, P. Bajerová, M. Adam, K. Ventura,
- 520 9_
- $a A method for focused ultrasonic extraction of nitroglycerin, triphenyl amine and acetyl tributyl citrate presented in double-base propellant samples following by the gas chromatography/mass spectrometry analysis was developed. A face-centered central composite design of the experiments and response surface modeling was used for optimization of the time, amplitude and sample amount. The dichloromethane was used as the extractant solvent. The optimal extraction conditions with respect to the maximum yield of the lowest abundant compound triphenyl amine were found at the 20 min extraction time, 35% amplitude of ultrasonic waves and 2.5 g of the propellant sample. The results obtained under optimal conditions were compared with the results achieved with validated Soxhlet extraction method, which is typically used for isolation and pre-concentration of compounds from the samples of explosives. The extraction yields for acetyl tributyl citrate using both extraction methods were comparable; however, the yield of ultrasonic extraction of nitroglycerin and triphenyl amine was lower than using Soxhlet extraction. The possible sources of different extraction yields are estimated and discussed.
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Česla, Petr $u -
- 700 1_
- $a Bajerová, Petra $u -
- 700 1_
- $a Adam, Martin $u - $7 xx0064600
- 700 1_
- $a Ventura, Karel $u -
- 773 0_
- $w MED00004484 $t Talanta $x 1873-3573 $g Roč. 99(2012), s. 316-22
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22967558 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20130424 $b ABA008
- 991 __
- $a 20130424135218 $b ABA008
- 999 __
- $a ind $b bmc $g 979267 $s 814387
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2012 $b 99 $d 316-22 $i 1873-3573 $m Talanta $n Talanta $x MED00004484
- LZP __
- $a Pubmed-20130424