-
Je něco špatně v tomto záznamu ?
The minimizing of fluorescence background in Raman optical activity and Raman spectra of human blood plasma
M. Tatarkovič, A. Synytsya, L. Šťovíčková, B. Bunganič, M. Miškovičová, L. Petruželka, V. Setnička,
Jazyk angličtina Země Německo
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
NT13259
MZ0
CEP - Centrální evidence projektů
Digitální knihovna NLK
Plný text - Článek
Zdroj
NLK
ProQuest Central
od 2011-01-01 do Před 1 rokem
Medline Complete (EBSCOhost)
od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest)
od 2011-01-01 do Před 1 rokem
- MeSH
- fluorescence MeSH
- krevní plazma chemie MeSH
- lidé MeSH
- optická otáčivost MeSH
- Ramanova spektroskopie přístrojové vybavení metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Raman optical activity (ROA) is inherently sensitive to the secondary structure of biomolecules, which makes it a method of interest for finding new approaches to clinical applications based on blood plasma analysis, for instance the diagnostics of several protein-misfolding diseases. Unfortunately, real blood plasma exhibits strong background fluorescence when excited at 532 nm; hence, measuring the ROA spectra appears to be impossible. Therefore, we established a suitable method using a combination of kinetic quenchers, filtering, photobleaching, and a mathematical correction of residual fluorescence. Our method reduced the background fluorescence approximately by 90%, which allowed speedup for each measurement by an average of 50%. In addition, the signal-to-noise ratio was significantly increased, while the baseline distortion remained low. We assume that our method is suitable for the investigation of human blood plasma by ROA and may lead to the development of a new tool for clinical diagnostics.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16000467
- 003
- CZ-PrNML
- 005
- 20170518134019.0
- 007
- ta
- 008
- 160108s2015 gw f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s00216-014-8358-7 $2 doi
- 035 __
- $a (PubMed)25486921
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Tatarkovič, Michal $u Department of Analytical Chemistry, Institute of Chemical Technology Prague, Technická 5, 166 28, Prague 6, Czech Republic. $7 xx0213747
- 245 14
- $a The minimizing of fluorescence background in Raman optical activity and Raman spectra of human blood plasma / $c M. Tatarkovič, A. Synytsya, L. Šťovíčková, B. Bunganič, M. Miškovičová, L. Petruželka, V. Setnička,
- 520 9_
- $a Raman optical activity (ROA) is inherently sensitive to the secondary structure of biomolecules, which makes it a method of interest for finding new approaches to clinical applications based on blood plasma analysis, for instance the diagnostics of several protein-misfolding diseases. Unfortunately, real blood plasma exhibits strong background fluorescence when excited at 532 nm; hence, measuring the ROA spectra appears to be impossible. Therefore, we established a suitable method using a combination of kinetic quenchers, filtering, photobleaching, and a mathematical correction of residual fluorescence. Our method reduced the background fluorescence approximately by 90%, which allowed speedup for each measurement by an average of 50%. In addition, the signal-to-noise ratio was significantly increased, while the baseline distortion remained low. We assume that our method is suitable for the investigation of human blood plasma by ROA and may lead to the development of a new tool for clinical diagnostics.
- 650 _2
- $a fluorescence $7 D005453
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a optická otáčivost $7 D009904
- 650 _2
- $a krevní plazma $x chemie $7 D010949
- 650 _2
- $a Ramanova spektroskopie $x přístrojové vybavení $x metody $7 D013059
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Synytsya, Alla $7 xx0145872
- 700 1_
- $a Šťovíčková, Lucie $7 xx0213748
- 700 1_
- $a Bunganič, Bohuš $7 xx0200314
- 700 1_
- $a Miškovičová, Michaela $7 xx0198620
- 700 1_
- $a Petruželka, Luboš, $d 1952- $7 jn19990209650
- 700 1_
- $a Setnička, Vladimír, $d 1976- $7 xx0200737
- 773 0_
- $w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 407, č. 5 (2015), s. 1335-1342
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/25486921 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20160108 $b ABA008
- 991 __
- $a 20170518134408 $b ABA008
- 999 __
- $a ok $b bmc $g 1102748 $s 924673
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 407 $c 5 $d 1335-1342 $e 20141209 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
- GRA __
- $a NT13259 $p MZ0
- LZP __
- $a Pubmed-20160108