Transcatheter aortic valve implantation: long-term clinical outcome and valve durability

J. Sulzenko, P. Tousek, V. Kocka, P. Widimsky,

. 2015 ; 12 (5) : 529-35. [pub] 20150703

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc16020602

Transcatheter aortic valve implantation (TAVI) is a widely used intervention in patients who are at high risk or contraindicated for cardiac surgery. The procedure is technically feasible in most patients and has very good mid-term clinical outcomes. In this special report, we evaluated the long-term outcome after TAVI and durability of percutaneously implanted aortic valve prostheses by reviewing all available long-term follow-up data. We herein present the clinical and hemodynamic data derived from patients 2-5 years after TAVI and describe all published cases of prosthesis degeneration.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc16020602
003      
CZ-PrNML
005      
20160727102746.0
007      
ta
008      
160722s2015 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1586/17434440.2015.1063994 $2 doi
024    7_
$a 10.1586/17434440.2015.1063994 $2 doi
035    __
$a (PubMed)26134100
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Sulzenko, Jakub $u a Cardiocenter, Third Faculty of Medicine, Charles University, Prague, Czech Republic.
245    10
$a Transcatheter aortic valve implantation: long-term clinical outcome and valve durability / $c J. Sulzenko, P. Tousek, V. Kocka, P. Widimsky,
520    9_
$a Transcatheter aortic valve implantation (TAVI) is a widely used intervention in patients who are at high risk or contraindicated for cardiac surgery. The procedure is technically feasible in most patients and has very good mid-term clinical outcomes. In this special report, we evaluated the long-term outcome after TAVI and durability of percutaneously implanted aortic valve prostheses by reviewing all available long-term follow-up data. We herein present the clinical and hemodynamic data derived from patients 2-5 years after TAVI and describe all published cases of prosthesis degeneration.
650    _2
$a aortální chlopeň $x patologie $x patofyziologie $7 D001021
650    _2
$a hemodynamika $7 D006439
650    _2
$a lidé $7 D006801
650    _2
$a časové faktory $7 D013997
650    12
$a transkatetrální implantace aortální chlopně $x mortalita $7 D065467
650    _2
$a výsledek terapie $7 D016896
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Tousek, Petr
700    1_
$a Kocka, Viktor
700    1_
$a Widimsky, Petr
773    0_
$w MED00174420 $t Expert review of medical devices $x 1745-2422 $g Roč. 12, č. 5 (2015), s. 529-35
856    41
$u https://pubmed.ncbi.nlm.nih.gov/26134100 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20160722 $b ABA008
991    __
$a 20160727103006 $b ABA008
999    __
$a ok $b bmc $g 1155272 $s 945130
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2015 $b 12 $c 5 $d 529-35 $e 20150703 $i 1745-2422 $m Expert review of medical devices $n Expert Rev Med Devices $x MED00174420
LZP    __
$a Pubmed-20160722

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...