Is ionized oxygen negatively or positively charged more effective for carboxyhemoglobin reduction compare to medical oxygen at atmospheric pressure
S. Perečinský, I. Kron, I. Engler, L. Murínová, V. Donič, M. Varga, A. Marossy, Ľ. Legáth
Jazyk angličtina Země Česko
Typ dokumentu časopisecké články
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- ionty terapeutické užití MeSH
- kyslík chemie terapeutické užití MeSH
- lidé MeSH
- otrava oxidem uhelnatým terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Carbon monoxide (CO) reversibly binds to hemoglobin forming carboxyhemoglobin (COHb). CO competes with O(2) for binding place in hemoglobin leading to tissue hypoxia. Already 30 % saturation of COHb can be deadly. Medical oxygen at atmospheric pressure as a therapy is not enough effective. Therefore hyperbaric oxygen O(2) inhalation is recommended. There was a question if partially ionized oxygen can be a better treatment at atmospheric pressure. In present study we evaluated effect of partially ionized oxygen produced by device Oxygen Ion 3000 by Dr. Engler in elimination of COHb in vitro experiments and in smokers. Diluted blood with different content of CO was purged with 5 l/min of either medicinal oxygen O(2), negatively ionized O(2) or positively ionized O(2) for 15 min, then the COHb content was checked. In vivo study, 15 smokers inhaled of either medicinal oxygen O(2) or negatively ionized O(2), than we compared CO levels in expired air before and after inhalation. In both studies we found the highest elimination of CO when we used negatively ionized O(2). These results confirmed the benefit of short inhalation of negatively ionized O(2), in frame of Ionized Oxygen Therapy (I O(2)Th/Engler) which could be used in smokers for decreasing of COHb in blood.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc16031120
- 003
- CZ-PrNML
- 005
- 20190619090608.0
- 007
- ta
- 008
- 161101s2015 xr d f 000 0|ENG||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.932899 $2 doi
- 035 __
- $a (PubMed)26047377
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a ENG
- 044 __
- $a xr
- 100 1_
- $a Perečinský, Slavomír $u Department of Occupational Medicine and Clinical Toxicology, Faculty of Medicine, P. J. Šafárik University and the L. Pasteur University Hospital, Košice, Slovakia $7 xx0101010
- 245 10
- $a Is ionized oxygen negatively or positively charged more effective for carboxyhemoglobin reduction compare to medical oxygen at atmospheric pressure / $c S. Perečinský, I. Kron, I. Engler, L. Murínová, V. Donič, M. Varga, A. Marossy, Ľ. Legáth
- 520 9_
- $a Carbon monoxide (CO) reversibly binds to hemoglobin forming carboxyhemoglobin (COHb). CO competes with O(2) for binding place in hemoglobin leading to tissue hypoxia. Already 30 % saturation of COHb can be deadly. Medical oxygen at atmospheric pressure as a therapy is not enough effective. Therefore hyperbaric oxygen O(2) inhalation is recommended. There was a question if partially ionized oxygen can be a better treatment at atmospheric pressure. In present study we evaluated effect of partially ionized oxygen produced by device Oxygen Ion 3000 by Dr. Engler in elimination of COHb in vitro experiments and in smokers. Diluted blood with different content of CO was purged with 5 l/min of either medicinal oxygen O(2), negatively ionized O(2) or positively ionized O(2) for 15 min, then the COHb content was checked. In vivo study, 15 smokers inhaled of either medicinal oxygen O(2) or negatively ionized O(2), than we compared CO levels in expired air before and after inhalation. In both studies we found the highest elimination of CO when we used negatively ionized O(2). These results confirmed the benefit of short inhalation of negatively ionized O(2), in frame of Ionized Oxygen Therapy (I O(2)Th/Engler) which could be used in smokers for decreasing of COHb in blood.
- 650 _2
- $a otrava oxidem uhelnatým $x terapie $7 D002249
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a ionty $x terapeutické užití $7 D007477
- 650 _2
- $a kyslík $x chemie $x terapeutické užití $7 D010100
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Kron, Ivan $7 xx0082852 $u Institute of Medical and Clinical Biochemistry and Labmed, Faculty of Medicine, P. J. Šafárik University, Košice, Slovakia
- 700 1_
- $a Engler, Ivan, $d 1931-2017 $7 xx0237184 $u Department of Human Physiology, Faculty of Medicine, P. J. Šafárik University, Košice, Slovakia
- 700 1_
- $a Murínová, L. $7 _AN054737 $u Department of Occupational Medicine and Clinical Toxicology, Faculty of Medicine, P. J. Šafárik University and the L. Pasteur University Hospital, Košice, Slovakia
- 700 1_
- $a Donič, Viliam $7 xx0063734 $u Department of Human Physiology, Faculty of Medicine, P. J. Šafárik University, Košice, Slovakia
- 700 1_
- $a Varga, Marek $7 _AN046851 $u Institute of Medical and Clinical Biochemistry and Labmed, Faculty of Medicine, P. J. Šafárik University, Košice, Slovakia
- 700 1_
- $a Marossy, Alexander $7 _AN029853 $u Department of Human Physiology, Faculty of Medicine, P. J. Šafárik University, Košice, Slovakia
- 700 1_
- $a Legáth, Ľubomír $7 xx0074096 $u Department of Occupational Medicine and Clinical Toxicology, Faculty of Medicine, P. J. Šafárik University and the L. Pasteur University Hospital, Košice, Slovakia
- 773 0_
- $w MED00003824 $t Physiological research $x 1802-9973 $g Roč. 64, č. 6 (2015), s. 951-955
- 856 41
- $u http://www.biomed.cas.cz/physiolres/ $y domovská stránka časopisu
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 4 $z 0
- 990 __
- $a 20161101 $b ABA008
- 991 __
- $a 20190619090804 $b ABA008
- 999 __
- $a ok $b bmc $g 1172207 $s 955778
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2015 $b 64 $c 6 $d 951-955 $e 2015Jun05 $i 1802-9973 $m Physiological research $n Physiol. Res. (Print) $x MED00003824
- LZP __
- $b NLK118 $a Pubmed-20161101