We report the first vibrational circular dichroism (VCD) measurement of spatial heterogeneity in a sample using infrared (IR) microsampling. Vibrational circular dichroism spectra are typically measured using a standard IR cell with an IR beam diameter of 10 mm or greater making it impossible to investigate the spatial heterogeneity of a solid film sample. We have constructed a VCD sampling assembly with either 3 mm or 1 mm spatial resolution. An XY-translation stage was used to measure spectra at different spatial locations producing IR and VCD maps of the sample. In addition, a rotating sample stage was employed using a dual photoelastic modulator (PEM) setup to suppress artifacts due to linear birefringence in solid-phase or film samples. Infrared and VCD mapping of an insulin fibril film has been carried out at both 3 and 1 mm spatial resolution, and lysozyme films were mapped at 1 mm resolution. The IR spectra of different spots vary in intensity due primarily to sample thickness. The changes in the VCD intensity across the map largely correlate to corresponding changes in the IR map. Closer inspection of the insulin map revealed changes in the relative intensities of the VCD spectra not present in the parent IR spectra, which indicated differences in the degree of supramolecular chirality of the fibrils in the various spatial regions. For lysozyme films, in addition to different degrees of supramolecular chirality, reversal of the net fibril chirality was observed. The large signal-to-noise ratio observed at 1 mm resolution implies the feasibility of further increasing the spatial resolution by one or two orders of magnitude for protein fibril film samples.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc18033928
003      
CZ-PrNML
005      
20181023103525.0
007      
ta
008      
181008s2017 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1177/0003702817701457 $2 doi
035    __
$a (PubMed)28436688
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Lu, Xuefang $u 1 BioTools Inc., Jupiter, FL, USA.
245    12
$a A Vibrational Circular Dichroism Microsampling Accessory: Mapping Enhanced Vibrational Circular Dichroism in Amyloid Fibril Films / $c X. Lu, H. Li, JW. Nafie, T. Pazderka, M. Pazderková, RK. Dukor, LA. Nafie,
520    9_
$a We report the first vibrational circular dichroism (VCD) measurement of spatial heterogeneity in a sample using infrared (IR) microsampling. Vibrational circular dichroism spectra are typically measured using a standard IR cell with an IR beam diameter of 10 mm or greater making it impossible to investigate the spatial heterogeneity of a solid film sample. We have constructed a VCD sampling assembly with either 3 mm or 1 mm spatial resolution. An XY-translation stage was used to measure spectra at different spatial locations producing IR and VCD maps of the sample. In addition, a rotating sample stage was employed using a dual photoelastic modulator (PEM) setup to suppress artifacts due to linear birefringence in solid-phase or film samples. Infrared and VCD mapping of an insulin fibril film has been carried out at both 3 and 1 mm spatial resolution, and lysozyme films were mapped at 1 mm resolution. The IR spectra of different spots vary in intensity due primarily to sample thickness. The changes in the VCD intensity across the map largely correlate to corresponding changes in the IR map. Closer inspection of the insulin map revealed changes in the relative intensities of the VCD spectra not present in the parent IR spectra, which indicated differences in the degree of supramolecular chirality of the fibrils in the various spatial regions. For lysozyme films, in addition to different degrees of supramolecular chirality, reversal of the net fibril chirality was observed. The large signal-to-noise ratio observed at 1 mm resolution implies the feasibility of further increasing the spatial resolution by one or two orders of magnitude for protein fibril film samples.
650    _2
$a amyloid $x analýza $x chemie $7 D000682
650    _2
$a zvířata $7 D000818
650    _2
$a artefakty $7 D016477
650    _2
$a skot $7 D002417
650    _2
$a cirkulární dichroismus $x metody $7 D002942
650    _2
$a inzulin $x analýza $x chemie $7 D007328
650    _2
$a muramidasa $x analýza $x chemie $7 D009113
650    _2
$a počítačové zpracování signálu $7 D012815
650    _2
$a spektroskopie infračervená s Fourierovou transformací $7 D017550
650    _2
$a vibrace $7 D014732
655    _2
$a časopisecké články $7 D016428
700    1_
$a Li, Honggang $u 1 BioTools Inc., Jupiter, FL, USA.
700    1_
$a Nafie, Jordan W $u 1 BioTools Inc., Jupiter, FL, USA.
700    1_
$a Pazderka, Tomáš $u 2 Institute of Physics, Faculty of Mathematics and Physics, Charles University, Prague, Czech Republic.
700    1_
$a Pazderková, Markéta $u 2 Institute of Physics, Faculty of Mathematics and Physics, Charles University, Prague, Czech Republic.
700    1_
$a Dukor, Rina K $u 1 BioTools Inc., Jupiter, FL, USA.
700    1_
$a Nafie, Laurence A $u 1 BioTools Inc., Jupiter, FL, USA. 3 Department of Chemistry, Syracuse University, Syracuse, NY, USA.
773    0_
$w MED00008276 $t Applied spectroscopy $x 1943-3530 $g Roč. 71, č. 6 (2017), s. 1117-1126
856    41
$u https://pubmed.ncbi.nlm.nih.gov/28436688 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20181008 $b ABA008
991    __
$a 20181023104032 $b ABA008
999    __
$a ok $b bmc $g 1339658 $s 1030922
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2017 $b 71 $c 6 $d 1117-1126 $e 20170424 $i 1943-3530 $m Applied spectroscopy $n Appl Spectrosc $x MED00008276
LZP    __
$a Pubmed-20181008

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...