-
Je něco špatně v tomto záznamu ?
Analysis of OJIP Chlorophyll Fluorescence Kinetics and QA Reoxidation Kinetics by Direct Fast Imaging
H. Küpper, Z. Benedikty, F. Morina, E. Andresen, A. Mishra, M. Trtílek,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Free Medical Journals
od 1926 do Před 1 rokem
Open Access Digital Library
od 1926-01-01
PubMed
30563922
DOI
10.1104/pp.18.00953
Knihovny.cz E-zdroje
- MeSH
- Arabidopsis cytologie metabolismus MeSH
- Brassicaceae cytologie účinky léků metabolismus MeSH
- chlorofyl chemie metabolismus MeSH
- design vybavení MeSH
- fluorescence MeSH
- fluorescenční mikroskopie přístrojové vybavení metody MeSH
- fotosyntéza MeSH
- Glycine max cytologie účinky léků metabolismus MeSH
- kinetika MeSH
- listy rostlin cytologie MeSH
- mezofylové buňky metabolismus MeSH
- plastochinon metabolismus MeSH
- zinek metabolismus MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Chlorophyll fluorescence kinetic analysis has become an important tool in basic and applied research on plant physiology and agronomy. While early systems recorded the integrated kinetics of a selected spot or plant, later systems enabled imaging of at least the slower parts of the kinetics (20-ms time resolution). For faster events, such as the rise from the basic dark-adapted fluorescence yield to the maximum (OJIP transient), or the fluorescence yield decrease during reoxidation of plastoquinone A after a saturating flash, integrative systems are used because of limiting speed of the available imaging systems. In our new macroscopic and microscopic systems, the OJIP or plastonique A reoxidation fluorescence transients are directly imaged using an ultrafast camera. The advantage of such systems compared to nonimaging measurements is the analysis of heterogeneity of measured parameters, for example between the photosynthetic tissue near the veins and the tissue further away from the veins. Further, in contrast to the pump-and-probe measurement, direct imaging allows for measuring the transition of the plant from the dark-acclimated to a light-acclimated state via a quenching analysis protocol in which every supersaturating flash is coupled to a measurement of the fast fluorescence rise. We show that pump-and-probe measurement of OJIP is prone to artifacts, which are eliminated with the direct measurement. The examples of applications shown here, zinc deficiency and cadmium toxicity, demonstrate that this novel imaging platform can be used for detection and analysis of a range of alterations of the electron flow around PSII.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19034858
- 003
- CZ-PrNML
- 005
- 20191015102137.0
- 007
- ta
- 008
- 191007s2019 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1104/pp.18.00953 $2 doi
- 035 __
- $a (PubMed)30563922
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Küpper, Hendrik $u Biology Center of the Czech Academy of Sciences, Institute of Plant Molecular Biology, Department of Plant Biophysics and Biochemistry, 370 05 České Budějovice, Czech Republic hendrik.kuepper@umbr.cas.cz. University of South Bohemia, Department of Experimental Plant Biology, 370 05 České Budějovice, Czech Republic.
- 245 10
- $a Analysis of OJIP Chlorophyll Fluorescence Kinetics and QA Reoxidation Kinetics by Direct Fast Imaging / $c H. Küpper, Z. Benedikty, F. Morina, E. Andresen, A. Mishra, M. Trtílek,
- 520 9_
- $a Chlorophyll fluorescence kinetic analysis has become an important tool in basic and applied research on plant physiology and agronomy. While early systems recorded the integrated kinetics of a selected spot or plant, later systems enabled imaging of at least the slower parts of the kinetics (20-ms time resolution). For faster events, such as the rise from the basic dark-adapted fluorescence yield to the maximum (OJIP transient), or the fluorescence yield decrease during reoxidation of plastoquinone A after a saturating flash, integrative systems are used because of limiting speed of the available imaging systems. In our new macroscopic and microscopic systems, the OJIP or plastonique A reoxidation fluorescence transients are directly imaged using an ultrafast camera. The advantage of such systems compared to nonimaging measurements is the analysis of heterogeneity of measured parameters, for example between the photosynthetic tissue near the veins and the tissue further away from the veins. Further, in contrast to the pump-and-probe measurement, direct imaging allows for measuring the transition of the plant from the dark-acclimated to a light-acclimated state via a quenching analysis protocol in which every supersaturating flash is coupled to a measurement of the fast fluorescence rise. We show that pump-and-probe measurement of OJIP is prone to artifacts, which are eliminated with the direct measurement. The examples of applications shown here, zinc deficiency and cadmium toxicity, demonstrate that this novel imaging platform can be used for detection and analysis of a range of alterations of the electron flow around PSII.
- 650 _2
- $a Arabidopsis $x cytologie $x metabolismus $7 D017360
- 650 _2
- $a Brassicaceae $x cytologie $x účinky léků $x metabolismus $7 D019607
- 650 _2
- $a chlorofyl $x chemie $x metabolismus $7 D002734
- 650 _2
- $a design vybavení $7 D004867
- 650 _2
- $a fluorescence $7 D005453
- 650 _2
- $a kinetika $7 D007700
- 650 _2
- $a mezofylové buňky $x metabolismus $7 D058503
- 650 _2
- $a fluorescenční mikroskopie $x přístrojové vybavení $x metody $7 D008856
- 650 _2
- $a fotosyntéza $7 D010788
- 650 _2
- $a listy rostlin $x cytologie $7 D018515
- 650 _2
- $a plastochinon $x metabolismus $7 D010971
- 650 _2
- $a Glycine max $x cytologie $x účinky léků $x metabolismus $7 D013025
- 650 _2
- $a zinek $x metabolismus $7 D015032
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Benedikty, Zuzana $u Photon Systems Instruments, 664 24 Drasov, Czech Republic.
- 700 1_
- $a Morina, Filis $u Biology Center of the Czech Academy of Sciences, Institute of Plant Molecular Biology, Department of Plant Biophysics and Biochemistry, 370 05 České Budějovice, Czech Republic.
- 700 1_
- $a Andresen, Elisa $u Biology Center of the Czech Academy of Sciences, Institute of Plant Molecular Biology, Department of Plant Biophysics and Biochemistry, 370 05 České Budějovice, Czech Republic.
- 700 1_
- $a Mishra, Archana $u Biology Center of the Czech Academy of Sciences, Institute of Plant Molecular Biology, Department of Plant Biophysics and Biochemistry, 370 05 České Budějovice, Czech Republic.
- 700 1_
- $a Trtílek, Martin $u Photon Systems Instruments, 664 24 Drasov, Czech Republic.
- 773 0_
- $w MED00005317 $t Plant physiology $x 1532-2548 $g Roč. 179, č. 2 (2019), s. 369-381
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30563922 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20191015102603 $b ABA008
- 999 __
- $a ok $b bmc $g 1451518 $s 1073408
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 179 $c 2 $d 369-381 $e 20181218 $i 1532-2548 $m Plant physiology $n Plant Physiol $x MED00005317
- LZP __
- $a Pubmed-20191007