-
Something wrong with this record ?
Novel approach to computerized breath detection in lung function diagnostics
J. Horáček, V. Koucký, M. Hladík,
Language English Country United States
Document type Journal Article, Research Support, Non-U.S. Gov't
NLK
ProQuest Central
from 2003-01-01 to 2023-12-31
Nursing & Allied Health Database (ProQuest)
from 2003-01-01 to 2023-12-31
Health & Medicine (ProQuest)
from 2003-01-01 to 2023-12-31
- MeSH
- Algorithms * MeSH
- Diagnosis, Computer-Assisted methods MeSH
- Child MeSH
- Infant MeSH
- Humans MeSH
- Adolescent MeSH
- Signal Processing, Computer-Assisted * MeSH
- Child, Preschool MeSH
- Respiratory Function Tests MeSH
- Check Tag
- Child MeSH
- Infant MeSH
- Humans MeSH
- Adolescent MeSH
- Male MeSH
- Child, Preschool MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
BACKGROUND: Breath detection, i.e. its precise delineation in time is a crucial step in lung function data analysis as obtaining any clinically relevant index is based on the proper localization of breath ends. Current threshold or smoothing algorithms suffer from severe inaccuracy in cases of suboptimal data quality. Especially in infants, the precise analysis is of utmost importance. The key objective of our work is to design an algorithm for accurate breath detection in severely distorted data. METHODS: Flow and gas concentration data from multiple breath washout test were the input information. Based on universal physiological characteristics of the respiratory tract we designed an algorithm for breath detection. Its accuracy was tested on severely distorted data from 19 patients with different types of breathing disorders. Its performance was compared to the performance of currently used algorithms and to the breath counts estimated by human experts. RESULTS: The novel algorithm outperformed the threshold algorithms with respect to their accuracy and had similar performance to human experts. It proved to be a highly robust and efficient approach in severely distorted data. This was demonstrated on patients with different pulmonary disorders. CONCLUSION: Our newly proposed algorithm is highly robust and universal. It works accurately even on severely distorted data, where the other tested algorithms failed. It does not require any pre-set thresholds or other patient-specific inputs. Consequently, it may be used with a broad spectrum of patients. It has the potential to replace current approaches to the breath detection in pulmonary function diagnostics.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19035092
- 003
- CZ-PrNML
- 005
- 20191014094759.0
- 007
- ta
- 008
- 191007s2018 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.compbiomed.2018.07.017 $2 doi
- 035 __
- $a (PubMed)30081237
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Horáček, Jaroslav $u Department of Applied Mathematics, Faculty of Mathematics and Physics, Charles University, Prague, Czech Republic. Electronic address: horacek@kam.mff.cuni.cz.
- 245 10
- $a Novel approach to computerized breath detection in lung function diagnostics / $c J. Horáček, V. Koucký, M. Hladík,
- 520 9_
- $a BACKGROUND: Breath detection, i.e. its precise delineation in time is a crucial step in lung function data analysis as obtaining any clinically relevant index is based on the proper localization of breath ends. Current threshold or smoothing algorithms suffer from severe inaccuracy in cases of suboptimal data quality. Especially in infants, the precise analysis is of utmost importance. The key objective of our work is to design an algorithm for accurate breath detection in severely distorted data. METHODS: Flow and gas concentration data from multiple breath washout test were the input information. Based on universal physiological characteristics of the respiratory tract we designed an algorithm for breath detection. Its accuracy was tested on severely distorted data from 19 patients with different types of breathing disorders. Its performance was compared to the performance of currently used algorithms and to the breath counts estimated by human experts. RESULTS: The novel algorithm outperformed the threshold algorithms with respect to their accuracy and had similar performance to human experts. It proved to be a highly robust and efficient approach in severely distorted data. This was demonstrated on patients with different pulmonary disorders. CONCLUSION: Our newly proposed algorithm is highly robust and universal. It works accurately even on severely distorted data, where the other tested algorithms failed. It does not require any pre-set thresholds or other patient-specific inputs. Consequently, it may be used with a broad spectrum of patients. It has the potential to replace current approaches to the breath detection in pulmonary function diagnostics.
- 650 _2
- $a mladiství $7 D000293
- 650 12
- $a algoritmy $7 D000465
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a předškolní dítě $7 D002675
- 650 _2
- $a diagnóza počítačová $x metody $7 D003936
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a kojenec $7 D007223
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a respirační funkční testy $7 D012129
- 650 12
- $a počítačové zpracování signálu $7 D012815
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Koucký, Václav $u Department of Paediatrics, 2nd Faculty of Medicine, Charles University, Prague, Czech Republic. Electronic address: vaclav.koucky@seznam.cz.
- 700 1_
- $a Hladík, Milan $u Department of Applied Mathematics, Faculty of Mathematics and Physics, Charles University, Prague, Czech Republic. Electronic address: hladik@kam.mff.cuni.cz.
- 773 0_
- $w MED00001218 $t Computers in biology and medicine $x 1879-0534 $g Roč. 101, č. - (2018), s. 1-6
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/30081237 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20191014095223 $b ABA008
- 999 __
- $a ok $b bmc $g 1451752 $s 1073642
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 101 $c - $d 1-6 $e 20180802 $i 1879-0534 $m Computers in biology and medicine $n Comput Biol Med $x MED00001218
- LZP __
- $a Pubmed-20191007