-
Je něco špatně v tomto záznamu ?
Low intrapatient variability of histomorphological findings in periprosthetic tissues from revised metal/ceramic on polyethylene joint arthroplasties
J. Vaculova, J. Gallo, P. Hurnik, O. Motyka, SB. Goodman, J. Dvorackova,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
Grantová podpora
NV16-31852A
MZ0
CEP - Centrální evidence projektů
PubMed
29044940
DOI
10.1002/jbm.b.33990
Knihovny.cz E-zdroje
- MeSH
- keramika * škodlivé účinky chemie MeSH
- kyčelní protézy * MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhrada kyčelního kloubu * MeSH
- polyethylen * škodlivé účinky chemie MeSH
- protézy - design * MeSH
- retrospektivní studie MeSH
- rozhraní kost/implantát patologie MeSH
- selhání protézy * MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The type of tissue response to implant by-products can be determined by examination of periprosthetic tissues. However, little is known about the most suitable location for tissue sampling. The main goal of this study was to evaluate the extent of variability in tissue response in relation to location of tissue sampling, implant fixation, age and sex in total joint arthroplasties with metal-on-polyethylene or ceramic-on-polyethylene bearing pairs. We processed 236 histology slides from 21 patients and focused on the association between the location of tissue samples and histological features. The presence of the synovial hyperplasia showed a significant association with the particular sampling site. A higher density of high endothelial cell venules was seen in the samples from around the joint, and polyethylene particles were more abundant in noncemented TJA but both findings did not show statistically significant association with the sampling site. The results showed a relatively small variance in the tissue response to prosthetic by-products among tissues sampled from the same patient. Our findings indicate that tissue samples retrieved from similar distance from around the TJA during the revision operation show comparable results of histological analysis. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2008-2018, 2018.
Department of Orthopaedic Surgery Stanford Medical Center Outpatient Clinic Redwood City CA 94063
Nanotechnology Centre VŠB Technical University of Ostrava Ostrava Poruba 708 33 Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19035561
- 003
- CZ-PrNML
- 005
- 20191014110953.0
- 007
- ta
- 008
- 191007s2018 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/jbm.b.33990 $2 doi
- 035 __
- $a (PubMed)29044940
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Vaculova, Jana $u Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Faculty Hospital Olomouc, Olomouc, 775 20, Czech Republic. Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic.
- 245 10
- $a Low intrapatient variability of histomorphological findings in periprosthetic tissues from revised metal/ceramic on polyethylene joint arthroplasties / $c J. Vaculova, J. Gallo, P. Hurnik, O. Motyka, SB. Goodman, J. Dvorackova,
- 520 9_
- $a The type of tissue response to implant by-products can be determined by examination of periprosthetic tissues. However, little is known about the most suitable location for tissue sampling. The main goal of this study was to evaluate the extent of variability in tissue response in relation to location of tissue sampling, implant fixation, age and sex in total joint arthroplasties with metal-on-polyethylene or ceramic-on-polyethylene bearing pairs. We processed 236 histology slides from 21 patients and focused on the association between the location of tissue samples and histological features. The presence of the synovial hyperplasia showed a significant association with the particular sampling site. A higher density of high endothelial cell venules was seen in the samples from around the joint, and polyethylene particles were more abundant in noncemented TJA but both findings did not show statistically significant association with the sampling site. The results showed a relatively small variance in the tissue response to prosthetic by-products among tissues sampled from the same patient. Our findings indicate that tissue samples retrieved from similar distance from around the TJA during the revision operation show comparable results of histological analysis. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2008-2018, 2018.
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a senioři nad 80 let $7 D000369
- 650 12
- $a náhrada kyčelního kloubu $7 D019644
- 650 _2
- $a rozhraní kost/implantát $x patologie $7 D000069343
- 650 12
- $a keramika $x škodlivé účinky $x chemie $7 D002516
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 12
- $a kyčelní protézy $7 D006622
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a lidé středního věku $7 D008875
- 650 12
- $a polyethylen $x škodlivé účinky $x chemie $7 D020959
- 650 12
- $a protézy - design $7 D011474
- 650 12
- $a selhání protézy $7 D011475
- 650 _2
- $a retrospektivní studie $7 D012189
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Gallo, Jiri $u Department of Orthopaedics, Faculty of Medicine and Dentistry, Palacky University Olomouc, Faculty Hospital Olomouc, Olomouc, 775 20, Czech Republic.
- 700 1_
- $a Hurnik, Pavel $u Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic. CBG Laboratory a. s., Ostrava 3, 703 00, Czech Republic.
- 700 1_
- $a Motyka, Oldrich $u Nanotechnology Centre, VŠB - Technical University of Ostrava, Ostrava-Poruba, 708 33, Czech Republic.
- 700 1_
- $a Goodman, Stuart B $u Department of Orthopaedic Surgery, Stanford Medical Center Outpatient Clinic, Redwood City, CA, 94063.
- 700 1_
- $a Dvorackova, Jana $u Department of Pathology, University Hospital Ostrava, Ostrava-Poruba, 708 52, Czech Republic. CBG Laboratory a. s., Ostrava 3, 703 00, Czech Republic.
- 773 0_
- $w MED00007497 $t Journal of biomedical materials research. Part B, Applied biomaterials $x 1552-4981 $g Roč. 106, č. 5 (2018), s. 2008-2018
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29044940 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20191014111417 $b ABA008
- 999 __
- $a ok $b bmc $g 1452221 $s 1074111
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 106 $c 5 $d 2008-2018 $e 20171016 $i 1552-4981 $m Journal of biomedical materials research. Part B, Applied biomaterials $n J Biomed Mater Res $x MED00007497
- GRA __
- $a NV16-31852A $p MZ0
- LZP __
- $a Pubmed-20191007