POSTAL TLD AUDIT OF HETEROGENEITY CORRECTIONS IN RADIOTHERAPY IN THE CZECH REPUBLIC

M. Kapuciánová, D. Ekendahl,

. 2019 ; 186 (2-3) : 373-376. [pub] 2019Dec31

Language English Country Great Britain

Document type Journal Article

In the Czech Republic, a more advanced version of postal audit in radiotherapy (RT) is available. It covers dose measurements with thermoluminescent dosemeters (TLD) in more complex conditions of irradiation, when dose distribution is affected by heterogeneities in the irradiated volume. Relative deviation between doses measured with TLDs and doses stated by RT centre should not exceed 3%. During 2015-2017, all Czech RT centres equipped with modern linear accelerators were subjected to this more advanced TLD audit. A total of  70% of participants complied with the limit of 3% in the first round of this audit.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20025341
003      
CZ-PrNML
005      
20201222153824.0
007      
ta
008      
201125s2019 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/ncz234 $2 doi
035    __
$a (PubMed)31834932
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Kapuciánová, Michaela $u National Radiation Protection Institute, Bartoskova 1450/28, 14000 Prague 4, Czech Republic.
245    10
$a POSTAL TLD AUDIT OF HETEROGENEITY CORRECTIONS IN RADIOTHERAPY IN THE CZECH REPUBLIC / $c M. Kapuciánová, D. Ekendahl,
520    9_
$a In the Czech Republic, a more advanced version of postal audit in radiotherapy (RT) is available. It covers dose measurements with thermoluminescent dosemeters (TLD) in more complex conditions of irradiation, when dose distribution is affected by heterogeneities in the irradiated volume. Relative deviation between doses measured with TLDs and doses stated by RT centre should not exceed 3%. During 2015-2017, all Czech RT centres equipped with modern linear accelerators were subjected to this more advanced TLD audit. A total of  70% of participants complied with the limit of 3% in the first round of this audit.
650    _2
$a lidé $7 D006801
650    _2
$a částice - urychlovače $x normy $7 D010315
650    _2
$a fotony $7 D017785
650    _2
$a zajištění kvality zdravotní péče $x normy $7 D011785
650    _2
$a řízení kvality $7 D011786
650    _2
$a celková dávka radioterapie $7 D011879
650    _2
$a plánování radioterapie pomocí počítače $x metody $x normy $7 D011880
650    _2
$a termoluminiscenční dozimetrie $x normy $7 D013819
651    _2
$a Česká republika $7 D018153
655    _2
$a časopisecké články $7 D016428
700    1_
$a Ekendahl, Daniela $u National Radiation Protection Institute, Bartoskova 1450/28, 14000 Prague 4, Czech Republic.
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 186, č. 2-3 (2019), s. 373-376
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31834932 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201222153820 $b ABA008
999    __
$a ok $b bmc $g 1599486 $s 1116027
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 186 $c 2-3 $d 373-376 $e 2019Dec31 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20201125

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...