Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

BRAVE-NET: Fully Automated Arterial Brain Vessel Segmentation in Patients With Cerebrovascular Disease

A. Hilbert, VI. Madai, EM. Akay, OU. Aydin, J. Behland, J. Sobesky, I. Galinovic, AA. Khalil, AA. Taha, J. Wuerfel, P. Dusek, T. Niendorf, JB. Fiebach, D. Frey, M. Livne

. 2020 ; 3 (-) : 552258. [pub] 20200925

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc21010243

Introduction: Arterial brain vessel assessment is crucial for the diagnostic process in patients with cerebrovascular disease. Non-invasive neuroimaging techniques, such as time-of-flight (TOF) magnetic resonance angiography (MRA) imaging are applied in the clinical routine to depict arteries. They are, however, only visually assessed. Fully automated vessel segmentation integrated into the clinical routine could facilitate the time-critical diagnosis of vessel abnormalities and might facilitate the identification of valuable biomarkers for cerebrovascular events. In the present work, we developed and validated a new deep learning model for vessel segmentation, coined BRAVE-NET, on a large aggregated dataset of patients with cerebrovascular diseases. Methods: BRAVE-NET is a multiscale 3-D convolutional neural network (CNN) model developed on a dataset of 264 patients from three different studies enrolling patients with cerebrovascular diseases. A context path, dually capturing high- and low-resolution volumes, and deep supervision were implemented. The BRAVE-NET model was compared to a baseline Unet model and variants with only context paths and deep supervision, respectively. The models were developed and validated using high-quality manual labels as ground truth. Next to precision and recall, the performance was assessed quantitatively by Dice coefficient (DSC); average Hausdorff distance (AVD); 95-percentile Hausdorff distance (95HD); and via visual qualitative rating. Results: The BRAVE-NET performance surpassed the other models for arterial brain vessel segmentation with a DSC = 0.931, AVD = 0.165, and 95HD = 29.153. The BRAVE-NET model was also the most resistant toward false labelings as revealed by the visual analysis. The performance improvement is primarily attributed to the integration of the multiscaling context path into the 3-D Unet and to a lesser extent to the deep supervision architectural component. Discussion: We present a new state-of-the-art of arterial brain vessel segmentation tailored to cerebrovascular pathology. We provide an extensive experimental validation of the model using a large aggregated dataset encompassing a large variability of cerebrovascular disease and an external set of healthy volunteers. The framework provides the technological foundation for improving the clinical workflow and can serve as a biomarker extraction tool in cerebrovascular diseases.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc21010243
003      
CZ-PrNML
005      
20210715081731.0
007      
ta
008      
210413s2020 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3389/frai.2020.552258 $2 doi
035    __
$a (PubMed)33733207
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Hilbert, Adam $u CLAIM - Charité Lab for Artificial Intelligence in Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany
245    10
$a BRAVE-NET: Fully Automated Arterial Brain Vessel Segmentation in Patients With Cerebrovascular Disease / $c A. Hilbert, VI. Madai, EM. Akay, OU. Aydin, J. Behland, J. Sobesky, I. Galinovic, AA. Khalil, AA. Taha, J. Wuerfel, P. Dusek, T. Niendorf, JB. Fiebach, D. Frey, M. Livne
520    9_
$a Introduction: Arterial brain vessel assessment is crucial for the diagnostic process in patients with cerebrovascular disease. Non-invasive neuroimaging techniques, such as time-of-flight (TOF) magnetic resonance angiography (MRA) imaging are applied in the clinical routine to depict arteries. They are, however, only visually assessed. Fully automated vessel segmentation integrated into the clinical routine could facilitate the time-critical diagnosis of vessel abnormalities and might facilitate the identification of valuable biomarkers for cerebrovascular events. In the present work, we developed and validated a new deep learning model for vessel segmentation, coined BRAVE-NET, on a large aggregated dataset of patients with cerebrovascular diseases. Methods: BRAVE-NET is a multiscale 3-D convolutional neural network (CNN) model developed on a dataset of 264 patients from three different studies enrolling patients with cerebrovascular diseases. A context path, dually capturing high- and low-resolution volumes, and deep supervision were implemented. The BRAVE-NET model was compared to a baseline Unet model and variants with only context paths and deep supervision, respectively. The models were developed and validated using high-quality manual labels as ground truth. Next to precision and recall, the performance was assessed quantitatively by Dice coefficient (DSC); average Hausdorff distance (AVD); 95-percentile Hausdorff distance (95HD); and via visual qualitative rating. Results: The BRAVE-NET performance surpassed the other models for arterial brain vessel segmentation with a DSC = 0.931, AVD = 0.165, and 95HD = 29.153. The BRAVE-NET model was also the most resistant toward false labelings as revealed by the visual analysis. The performance improvement is primarily attributed to the integration of the multiscaling context path into the 3-D Unet and to a lesser extent to the deep supervision architectural component. Discussion: We present a new state-of-the-art of arterial brain vessel segmentation tailored to cerebrovascular pathology. We provide an extensive experimental validation of the model using a large aggregated dataset encompassing a large variability of cerebrovascular disease and an external set of healthy volunteers. The framework provides the technological foundation for improving the clinical workflow and can serve as a biomarker extraction tool in cerebrovascular diseases.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Madai, Vince I $u CLAIM - Charité Lab for Artificial Intelligence in Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany ; Faculty of Computing, Engineering and the Built Environment, School of Computing and Digital Technology, Birmingham City University, Birmingham, United Kingdom
700    1_
$a Akay, Ela M $u CLAIM - Charité Lab for Artificial Intelligence in Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany
700    1_
$a Aydin, Orhun U $u CLAIM - Charité Lab for Artificial Intelligence in Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany
700    1_
$a Behland, Jonas $u CLAIM - Charité Lab for Artificial Intelligence in Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany
700    1_
$a Sobesky, Jan $u Centre for Stroke Research Berlin, Charité Universitätsmedizin Berlin, Berlin, Germany ; Johanna-Etienne-Hospital, Neuss, Germany
700    1_
$a Galinovic, Ivana $u Centre for Stroke Research Berlin, Charité Universitätsmedizin Berlin, Berlin, Germany
700    1_
$a Khalil, Ahmed A $u Centre for Stroke Research Berlin, Charité Universitätsmedizin Berlin, Berlin, Germany ; Department of Neurology, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany ; Berlin School of Mind and Brain, Mind, Brain, Body Institute, Humboldt-Universität Berlin, Berlin, Germany ; Biomedical Innovation Academy, Berlin Institute of Health, Berlin, Germany
700    1_
$a Taha, Abdel A $u Research Studio Data Science, Research Studios Austria, Salzburg, Austria
700    1_
$a Wuerfel, Jens $u Department Biomedical Engineering, Medical Image Analysis Center AG, University of Basel, Basel, Switzerland
700    1_
$a Dusek, Petr $u Department of Neurology, 1st Faculty of Medicine, Centre of Clinical Neuroscience, General University Hospital in Prague, Charles University, Prague, Czechia
700    1_
$a Niendorf, Thoralf $u Berlin Ultrahigh Field Facility, Max Delbrück Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
700    1_
$a Fiebach, Jochen B $u Centre for Stroke Research Berlin, Charité Universitätsmedizin Berlin, Berlin, Germany
700    1_
$a Frey, Dietmar $u CLAIM - Charité Lab for Artificial Intelligence in Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany
700    1_
$a Livne, Michelle $u CLAIM - Charité Lab for Artificial Intelligence in Medicine, Charité Universitätsmedizin Berlin, Berlin, Germany
773    0_
$w MED00207115 $t Frontiers in artificial intelligence $x 2624-8212 $g Roč. 3, č. - (2020), s. 552258
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33733207 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20210413 $b ABA008
991    __
$a 20210715081730 $b ABA008
999    __
$a ind $b bmc $g 1649743 $s 1130619
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 3 $c - $d 552258 $e 20200925 $i 2624-8212 $m Frontiers in artificial intelligence $n Front Artif Intell $x MED00207115
LZP    __
$a Pubmed-20210413

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...