• Something wrong with this record ?

On the relevance of boundary conditions and viscosity models in blood flow simulations in patient-specific aorto-coronary bypass models

A. Jonášová, J. Vimmr

. 2021 ; 37 (4) : e3439. [pub] 20210202

Language English Country Great Britain

Document type Journal Article, Research Support, Non-U.S. Gov't

Physiologically realistic results are the aim of every blood flow simulation. This is not different in aorto-coronary bypasses where the properties of the coronary circulation may significantly affect the relevance of the performed simulations. By considering three patient-specific bypass geometries, the present article focuses on two aspects of the coronary blood flow - its phasic flow pattern and its behaviour affected by blood rheology. For the phasic flow property, a multiscale modelling approach is chosen as a means to assess the ability of five different types of coronary boundary conditions (mean arterial pressure, Windkessel model and three lumped parameter models) to attain realistic coronary haemodynamics. From the analysed variants of boundary conditions, the best option in terms of physiological characteristics and its potential for use in patient-based simulations, is utilised to account for the effect of shear-dependent viscosity on the resulting haemodynamics and wall shear stress stimulation. Aside from the Newtonian model, the blood rheology is approximated by two non-Newtonian models in order to determine whether the choice of a viscosity model is important in simulations involving coronary circulation. A comprehensive analysis of obtained results demonstrated notable superiority of all lumped parameter models, especially in comparison to the constant outlet pressure, which regardless of bypass type gave overestimated and physiologically misleading results. In terms of rheology, it was noted that blood in undamaged coronary arteries behaves as a Newtonian fluid, whereas in vessels with atypical lumen geometry, such as that of anastomosis or stenosis, its shear-thinning behaviour should not be ignored.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22004488
003      
CZ-PrNML
005      
20220127145211.0
007      
ta
008      
220113s2021 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1002/cnm.3439 $2 doi
035    __
$a (PubMed)33464717
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Jonášová, Alena $u NTIS - New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Plzeň, Czech Republic $u Department of Mechanics, Faculty of Applied Sciences, University of West Bohemia, Plzeň, Czech Republic
245    10
$a On the relevance of boundary conditions and viscosity models in blood flow simulations in patient-specific aorto-coronary bypass models / $c A. Jonášová, J. Vimmr
520    9_
$a Physiologically realistic results are the aim of every blood flow simulation. This is not different in aorto-coronary bypasses where the properties of the coronary circulation may significantly affect the relevance of the performed simulations. By considering three patient-specific bypass geometries, the present article focuses on two aspects of the coronary blood flow - its phasic flow pattern and its behaviour affected by blood rheology. For the phasic flow property, a multiscale modelling approach is chosen as a means to assess the ability of five different types of coronary boundary conditions (mean arterial pressure, Windkessel model and three lumped parameter models) to attain realistic coronary haemodynamics. From the analysed variants of boundary conditions, the best option in terms of physiological characteristics and its potential for use in patient-based simulations, is utilised to account for the effect of shear-dependent viscosity on the resulting haemodynamics and wall shear stress stimulation. Aside from the Newtonian model, the blood rheology is approximated by two non-Newtonian models in order to determine whether the choice of a viscosity model is important in simulations involving coronary circulation. A comprehensive analysis of obtained results demonstrated notable superiority of all lumped parameter models, especially in comparison to the constant outlet pressure, which regardless of bypass type gave overestimated and physiologically misleading results. In terms of rheology, it was noted that blood in undamaged coronary arteries behaves as a Newtonian fluid, whereas in vessels with atypical lumen geometry, such as that of anastomosis or stenosis, its shear-thinning behaviour should not be ignored.
650    _2
$a rychlost toku krve $7 D001783
650    _2
$a počítačová simulace $7 D003198
650    _2
$a koronární cirkulace $7 D003326
650    12
$a koronární cévy $x chirurgie $7 D003331
650    12
$a hemodynamika $7 D006439
650    _2
$a lidé $7 D006801
650    _2
$a modely kardiovaskulární $7 D008955
650    _2
$a mechanický stres $7 D013314
650    _2
$a viskozita $7 D014783
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Vimmr, Jan $u NTIS - New Technologies for the Information Society, Faculty of Applied Sciences, University of West Bohemia, Plzeň, Czech Republic $u Department of Mechanics, Faculty of Applied Sciences, University of West Bohemia, Plzeň, Czech Republic
773    0_
$w MED00184043 $t International journal for numerical methods in biomedical engineering $x 2040-7947 $g Roč. 37, č. 4 (2021), s. e3439
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33464717 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127145207 $b ABA008
999    __
$a ok $b bmc $g 1751833 $s 1155637
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 37 $c 4 $d e3439 $e 20210202 $i 2040-7947 $m International journal for numerical methods in biomedical engineering $n Int j numer method biomed eng $x MED00184043
LZP    __
$a Pubmed-20220113

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...