Je něco špatně v tomto záznamu ?
Iron-doped calcium phytate nanoparticles as a bio-responsive contrast agent in 1H/31P magnetic resonance imaging
N. Ziółkowska, M. Vít, R. Laga, D. Jirák
Jazyk angličtina Země Velká Británie
Typ dokumentu časopisecké články, práce podpořená grantem
NLK
Directory of Open Access Journals
od 2011
Free Medical Journals
od 2011
Nature Open Access
od 2011-12-01
PubMed Central
od 2011
Europe PubMed Central
od 2011
ProQuest Central
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Open Access Digital Library
od 2011-01-01
Health & Medicine (ProQuest)
od 2011-01-01
ROAD: Directory of Open Access Scholarly Resources
od 2011
Springer Nature OA/Free Journals
od 2011-12-01
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
We present the MR properties of a novel bio-responsive phosphorus probe doped with iron for dual proton and phosphorus magnetic resonance imaging (1H/31P-MRI), which provide simultaneously complementary information. The probes consist of non-toxic biodegradable calcium phytate (CaIP6) nanoparticles doped with different amounts of cleavable paramagnetic Fe3+ ions. Phosphorus atoms in the phytate structure delivered an efficient 31P-MR signal, with iron ions altering MR contrast for both 1H and 31P-MR. The coordinated paramagnetic Fe3+ ions broadened the 31P-MR signal spectral line due to the short T2 relaxation time, resulting in more hypointense signal. However, when Fe3+ was decomplexed from the probe, relaxation times were prolonged. As a result of iron release, intensity of 1H-MR, as well as the 31P-MR signal increase. These 1H and 31P-MR dual signals triggered by iron decomplexation may have been attributable to biochemical changes in the environment with strong iron chelators, such as bacterial siderophore (deferoxamine). Analysing MR signal alternations as a proof-of-principle on a phantom at a 4.7 T magnetic field, we found that iron presence influenced 1H and 31P signals and signal recovery via iron chelation using deferoxamine.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22010062
- 003
- CZ-PrNML
- 005
- 20220425131657.0
- 007
- ta
- 008
- 220420s2022 xxk f 000 0|eng|e
- 009
- AR
- 024 7_
- $a 10.1038/s41598-022-06125-7 $2 doi
- 035 __
- $a (PubMed)35136162
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxk
- 100 1_
- $a Ziółkowska, Natalia $u Department of Diagnostic and Interventional Radiology, MR unit, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $u Institute of Biophysics and Informatics, First Faculty of Medicine, Charles University, Prague, Czech Republic
- 245 10
- $a Iron-doped calcium phytate nanoparticles as a bio-responsive contrast agent in 1H/31P magnetic resonance imaging / $c N. Ziółkowska, M. Vít, R. Laga, D. Jirák
- 520 9_
- $a We present the MR properties of a novel bio-responsive phosphorus probe doped with iron for dual proton and phosphorus magnetic resonance imaging (1H/31P-MRI), which provide simultaneously complementary information. The probes consist of non-toxic biodegradable calcium phytate (CaIP6) nanoparticles doped with different amounts of cleavable paramagnetic Fe3+ ions. Phosphorus atoms in the phytate structure delivered an efficient 31P-MR signal, with iron ions altering MR contrast for both 1H and 31P-MR. The coordinated paramagnetic Fe3+ ions broadened the 31P-MR signal spectral line due to the short T2 relaxation time, resulting in more hypointense signal. However, when Fe3+ was decomplexed from the probe, relaxation times were prolonged. As a result of iron release, intensity of 1H-MR, as well as the 31P-MR signal increase. These 1H and 31P-MR dual signals triggered by iron decomplexation may have been attributable to biochemical changes in the environment with strong iron chelators, such as bacterial siderophore (deferoxamine). Analysing MR signal alternations as a proof-of-principle on a phantom at a 4.7 T magnetic field, we found that iron presence influenced 1H and 31P signals and signal recovery via iron chelation using deferoxamine.
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Vít, Martin $u Department of Diagnostic and Interventional Radiology, MR unit, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $u Faculty of Mechatronics Informatics and Interdisciplinary Studies, Technical University of Liberec, Liberec, Czech Republic
- 700 1_
- $a Laga, Richard $u Institute of Macromolecular Chemistry, Czech Academy of Sciences, Prague, Czech Republic
- 700 1_
- $a Jirák, Daniel $u Department of Diagnostic and Interventional Radiology, MR unit, Institute for Clinical and Experimental Medicine, Prague, Czech Republic. daniel.jirak@ikem.cz $u Institute of Biophysics and Informatics, First Faculty of Medicine, Charles University, Prague, Czech Republic. daniel.jirak@ikem.cz
- 773 0_
- $w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 12, č. 1 (2022), s. 2118
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/35136162 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20220420 $b ABA008
- 991 __
- $a 20220425131655 $b ABA008
- 999 __
- $a ind $b bmc $g 1784474 $s 1161260
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 12 $c 1 $d 2118 $e 20220208 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
- LZP __
- $a Pubmed-20220420