Comparison of Mechanical Properties of Three Tissue Conditioners: An Evaluation In Vitro Study
M. Mikulewicz, K. Chojnacka, Z. Raszewski
Language English Country Switzerland
Document type Journal Article
NLK
Directory of Open Access Journals
from 2007
PubMed Central
from 2018
Europe PubMed Central
from 2018
ProQuest Central
from 2018-01-01
Open Access Digital Library
from 2014-01-01
Health & Medicine (ProQuest)
from 2018-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2007
- MeSH
- Bone Plates * MeSH
- Humans MeSH
- Methylmethacrylates * MeSH
- Water MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
Introduction: Tissue conditioners have been widely used in various clinical applications in dentistry, such as treating inflamed alveolar ridges, temporarily relining partial and complete dentures, and the acquisition of functional impressions for denture fabrication. This study aimed to investigate the mechanical properties of the most prevalent tissue conditioner materials on the market, including Tissue Conditioners (TC), Visco Gel (VG), and FITT (F). Materials and Methods: The three tissue conditioners, TC, VG, and F, were assessed based on the parameters mentioned above. The following tests were performed based on the ISO 10139-1 and ISO 10139-2 requirements: Shore A hardness, denture plate adhesion, sorption, water solubility, and contraction after 1 and 3 days in water. Additional tests are described in the literature, such as ethanol content and gelling time. The tests were carried out by storing the materials in water at 37 °C for 7 days. Results: The gel times of all tested materials exceeded 5 min (TC = 300 [s], VG = 350 [s]). In vitro, phthalate-free materials exhibited higher dissolution in water after 14 days (VG = -260.78 ± 11.31 μg/mm2) compared to F (-76.12 ± 7.11 μg/mm2) and experienced faster hardening when stored in distilled water (F = 33.4 ± 0.30 Sh. A, VG = 59.2 ± 0.60 Sh. A). They also showed greater contractions. The connection of all materials to the prosthesis plate was consistent at 0.11 MPa. The highest counterbalance after 3 days was observed in TC = 3.53 ± 1.12%. Conclusions: Materials containing plasticizers that are not phthalates have worse mechanical properties than products containing these substances. Since phthalates are not allowed to be used indefinitely in medical devices, additional research is necessary, especially in vivo, to develop safe materials with superior functional properties to newer-generation alternatives. In vitro results often do not agree fully with those of in vivo outcomes.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc23016821
- 003
- CZ-PrNML
- 005
- 20231026105524.0
- 007
- ta
- 008
- 231013s2023 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/medicina59081359 $2 doi
- 035 __
- $a (PubMed)37629649
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Mikulewicz, Marcin $u Department of Dentofacial Orthopaedics and Orthodontics, Division of Facial Abnormalities, Medical University of Wroclaw, Krakowska 26, 50-425 Wroclaw, Poland $1 https://orcid.org/0000000157540284
- 245 10
- $a Comparison of Mechanical Properties of Three Tissue Conditioners: An Evaluation In Vitro Study / $c M. Mikulewicz, K. Chojnacka, Z. Raszewski
- 520 9_
- $a Introduction: Tissue conditioners have been widely used in various clinical applications in dentistry, such as treating inflamed alveolar ridges, temporarily relining partial and complete dentures, and the acquisition of functional impressions for denture fabrication. This study aimed to investigate the mechanical properties of the most prevalent tissue conditioner materials on the market, including Tissue Conditioners (TC), Visco Gel (VG), and FITT (F). Materials and Methods: The three tissue conditioners, TC, VG, and F, were assessed based on the parameters mentioned above. The following tests were performed based on the ISO 10139-1 and ISO 10139-2 requirements: Shore A hardness, denture plate adhesion, sorption, water solubility, and contraction after 1 and 3 days in water. Additional tests are described in the literature, such as ethanol content and gelling time. The tests were carried out by storing the materials in water at 37 °C for 7 days. Results: The gel times of all tested materials exceeded 5 min (TC = 300 [s], VG = 350 [s]). In vitro, phthalate-free materials exhibited higher dissolution in water after 14 days (VG = -260.78 ± 11.31 μg/mm2) compared to F (-76.12 ± 7.11 μg/mm2) and experienced faster hardening when stored in distilled water (F = 33.4 ± 0.30 Sh. A, VG = 59.2 ± 0.60 Sh. A). They also showed greater contractions. The connection of all materials to the prosthesis plate was consistent at 0.11 MPa. The highest counterbalance after 3 days was observed in TC = 3.53 ± 1.12%. Conclusions: Materials containing plasticizers that are not phthalates have worse mechanical properties than products containing these substances. Since phthalates are not allowed to be used indefinitely in medical devices, additional research is necessary, especially in vivo, to develop safe materials with superior functional properties to newer-generation alternatives. In vitro results often do not agree fully with those of in vivo outcomes.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a kostní destičky $7 D001860
- 650 12
- $a methylmetakryláty $7 D008768
- 650 _2
- $a voda $7 D014867
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Chojnacka, Katarzyna $u Department of Advanced Material Technologies, Faculty of Chemistry, Wroclaw University of Science and Technology, Smoluchowskiego 25, 50-372 Wroclaw, Poland
- 700 1_
- $a Raszewski, Zbigniew $u SpofaDental, Markova 238, 506-01 Jicin, Czech Republic $1 https://orcid.org/0000000217353879
- 773 0_
- $w MED00180386 $t Medicina (Kaunas, Lithuania) $x 1648-9144 $g Roč. 59, č. 8 (2023)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/37629649 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20231013 $b ABA008
- 991 __
- $a 20231026105518 $b ABA008
- 999 __
- $a ok $b bmc $g 2000390 $s 1203183
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2023 $b 59 $c 8 $e 20230725 $i 1648-9144 $m Medicina $n Medicina (Kaunas) $x MED00180386
- LZP __
- $a Pubmed-20231013