Force Degradation of Intermaxillary Latex Elastics: Comparative In Vitro and In Vivo Study
L. Ptáčková, B. Ličková, W. Urbanová, D. Sluka, K. Portašíková, S. Chamlarová, I. Voborná, I. Dubovská
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, srovnávací studie
Grantová podpora
This research was funded by a research grant from Medical Faculty Palacký University in Olomouc, grant number IGA_LF_2022_008.
NLK
Directory of Open Access Journals
od 2015
Free Medical Journals
od 2015
PubMed Central
od 2015
Europe PubMed Central
od 2015
ProQuest Central
od 2015-10-01
Open Access Digital Library
od 2015-10-01
Health & Medicine (ProQuest)
od 2015-10-01
Wiley-Blackwell Open Access Titles
od 2015
PubMed
39887634
DOI
10.1002/cre2.70072
Knihovny.cz E-zdroje
- MeSH
- analýza zatížení zubů MeSH
- dospělí MeSH
- latex * chemie MeSH
- lidé MeSH
- mechanický stres MeSH
- mladý dospělý MeSH
- ortodontické aparáty MeSH
- ortodontické přístroje - design MeSH
- testování materiálů * MeSH
- zubní oblouk MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- srovnávací studie MeSH
OBJECTIVE: This study aimed to compare the force degradation of intermaxillary elastics (IE) in vitro and in vivo while stretching the IE to a precise diameter. MATERIALS AND METHODS: IE 3/16′′ medium Dentaurum from five different batches of packaging were analyzed. The in vivo study involved 10 volunteers, of which 100 IE were examined. To achieve three times the original diameter of the elastic, the distance between the upper canine and the lower dental arch was measured. Buttons were then placed in the mouth accordingly, and IE and passive aligners were inserted for five sessions of 48 h each. To investigate in vitro, 100 IE were placed in an incubator set at 37°C in a humid environment and stretched three times their diameter. The force of the elastics was measured in both investigations using a force meter at 0, 2, 8, 24, and 48 h. RESULTS: In all patients except one, the three times diameter distance extended from the upper canine to the lower second premolar. The force degradation in vivo at 2, 8, 24, and 48 h was 20.58%, 26.78%, 34.81%, and 38.56% and in vitro was 16.38%, 22.83%, 28.32%, and 30.78%. CONCLUSIONS: The amount of stretching of IE varies for each patient when using standard insertion points. The force of IE decreases exponentially, the force degradation in vivo being higher. The clinician must consider the force decrease when advising the patient of the time interval to change the elastics.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc25010009
- 003
- CZ-PrNML
- 005
- 20250429135547.0
- 007
- ta
- 008
- 250415s2025 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/cre2.70072 $2 doi
- 035 __
- $a (PubMed)39887634
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Ptáčková, Lucie $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University, Palackého, Olomouc, Czech Republic
- 245 10
- $a Force Degradation of Intermaxillary Latex Elastics: Comparative In Vitro and In Vivo Study / $c L. Ptáčková, B. Ličková, W. Urbanová, D. Sluka, K. Portašíková, S. Chamlarová, I. Voborná, I. Dubovská
- 520 9_
- $a OBJECTIVE: This study aimed to compare the force degradation of intermaxillary elastics (IE) in vitro and in vivo while stretching the IE to a precise diameter. MATERIALS AND METHODS: IE 3/16′′ medium Dentaurum from five different batches of packaging were analyzed. The in vivo study involved 10 volunteers, of which 100 IE were examined. To achieve three times the original diameter of the elastic, the distance between the upper canine and the lower dental arch was measured. Buttons were then placed in the mouth accordingly, and IE and passive aligners were inserted for five sessions of 48 h each. To investigate in vitro, 100 IE were placed in an incubator set at 37°C in a humid environment and stretched three times their diameter. The force of the elastics was measured in both investigations using a force meter at 0, 2, 8, 24, and 48 h. RESULTS: In all patients except one, the three times diameter distance extended from the upper canine to the lower second premolar. The force degradation in vivo at 2, 8, 24, and 48 h was 20.58%, 26.78%, 34.81%, and 38.56% and in vitro was 16.38%, 22.83%, 28.32%, and 30.78%. CONCLUSIONS: The amount of stretching of IE varies for each patient when using standard insertion points. The force of IE decreases exponentially, the force degradation in vivo being higher. The clinician must consider the force decrease when advising the patient of the time interval to change the elastics.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a latex $x chemie $7 D007840
- 650 12
- $a testování materiálů $7 D008422
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a ortodontické aparáty $7 D009967
- 650 _2
- $a mechanický stres $7 D013314
- 650 _2
- $a mladý dospělý $7 D055815
- 650 _2
- $a ortodontické přístroje - design $7 D016382
- 650 _2
- $a analýza zatížení zubů $7 D003799
- 650 _2
- $a zubní oblouk $7 D003724
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a srovnávací studie $7 D003160
- 700 1_
- $a Ličková, Barbora $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University, Palackého, Olomouc, Czech Republic
- 700 1_
- $a Urbanová, Wanda $u Department of Stomatology 3rd Medical Faculty Charles University and University Hospital Královské Vinohrady, Prague, Czech Republic $u Medical Faculty Charles University Pilsen, Pilsen, Czech Republic
- 700 1_
- $a Sluka, David $u Department of Stomatology 3rd Medical Faculty Charles University and University Hospital Královské Vinohrady, Prague, Czech Republic
- 700 1_
- $a Portašíková, Klaudia $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University, Palackého, Olomouc, Czech Republic
- 700 1_
- $a Chamlarová, Soňa $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University, Palackého, Olomouc, Czech Republic
- 700 1_
- $a Voborná, Iva $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University, Palackého, Olomouc, Czech Republic
- 700 1_
- $a Dubovská, Ivana $u Institute of Dentistry and Oral Sciences, Faculty of Medicine and Dentistry, Palacký University, Palackého, Olomouc, Czech Republic $1 https://orcid.org/0000000318816844 $7 xx0247576
- 773 0_
- $w MED00216320 $t Clinical and experimental dental research $x 2057-4347 $g Roč. 11, č. 1 (2025), s. e70072
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/39887634 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20250415 $b ABA008
- 991 __
- $a 20250429135542 $b ABA008
- 999 __
- $a ok $b bmc $g 2311400 $s 1247090
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2025 $b 11 $c 1 $d e70072 $e - $i 2057-4347 $m Clinical and experimental dental research $n Clin Exp Dent Res $x MED00216320
- GRA __
- $p This research was funded by a research grant from Medical Faculty Palacký University in Olomouc, grant number IGA_LF_2022_008.
- LZP __
- $a Pubmed-20250415