Průkaz mykobakterií radiometrickou metodou Bactec a standardní kultivacní metodou
[Detection of mycobacteria using the Bactec radiometry method and standard culture methods]
Jazyk čeština Země Česko Médium print
Typ dokumentu anglický abstrakt, časopisecké články
PubMed
9162452
- MeSH
- bakteriologické techniky * MeSH
- lidé MeSH
- Mycobacterium izolace a purifikace MeSH
- plicní tuberkulóza mikrobiologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
For parallel detection of mycobacteria by the radiometric method using a Bactec 460 TB apparatus and by the standard cultivation method 5383 specimens of pathological material from patients of in-patient TB departments (90%) and other health facilities (10%) were examined. 492 samples were positive. By the radiometric method alone 114 samples were positive and by cultivation only 15 samples. The mean period of detection was 12.9 days for the Bactec method, for the cultivation method 32.4 days. For the Bactec system 0.4 ml inoculum was used and one cultivation vessel, for the cultivation 0.4-0.6 ml inoculum and two egg media per sample. Of 15 samples positive on cultivation only, rarely colonies were obtained after 6-9 weeks' incubation.