New technique for the determination of radon diffusion coefficient in radon-proof membranes

. 2008 ; 130 (1) : 22-5. [epub] 20080408

Jazyk angličtina Země Velká Británie, Anglie Médium print-electronic

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/pmid18397928

This paper describes a new device and a method to determine the radon diffusion coefficient in damp-proof membranes developed in the Czech Republic. The main advantage of the device is that it enables tests to be carried out in all the known measuring modes used throughout Europe. Two recently developed computer programs are presented for the numerical modelling of the time-dependent radon transport through damp-proof membranes. According to this method, the radon diffusion coefficient is derived from the process of fitting the numerical solution to the measured curve of radon concentration in a receiver container. Numerical simulation and measured data are also compared. Reasons for disagreements between different methods and specific configurations of the measuring device are also discussed.

Citace poskytuje Crossref.org

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace