A Vibrational Circular Dichroism Microsampling Accessory: Mapping Enhanced Vibrational Circular Dichroism in Amyloid Fibril Films
Language English Country United States Media print-electronic
Document type Journal Article
- Keywords
- VCD, VCD spatial map, Vibrational circular dichroism, film heterogeneity, insulin, lysozyme, microsampling, protein amyloid fibrils,
- MeSH
- Amyloid analysis chemistry MeSH
- Artifacts MeSH
- Circular Dichroism methods MeSH
- Insulin analysis chemistry MeSH
- Muramidase analysis chemistry MeSH
- Signal Processing, Computer-Assisted MeSH
- Cattle MeSH
- Spectroscopy, Fourier Transform Infrared MeSH
- Vibration MeSH
- Animals MeSH
- Check Tag
- Cattle MeSH
- Animals MeSH
- Publication type
- Journal Article MeSH
- Names of Substances
- Amyloid MeSH
- Insulin MeSH
- Muramidase MeSH
We report the first vibrational circular dichroism (VCD) measurement of spatial heterogeneity in a sample using infrared (IR) microsampling. Vibrational circular dichroism spectra are typically measured using a standard IR cell with an IR beam diameter of 10 mm or greater making it impossible to investigate the spatial heterogeneity of a solid film sample. We have constructed a VCD sampling assembly with either 3 mm or 1 mm spatial resolution. An XY-translation stage was used to measure spectra at different spatial locations producing IR and VCD maps of the sample. In addition, a rotating sample stage was employed using a dual photoelastic modulator (PEM) setup to suppress artifacts due to linear birefringence in solid-phase or film samples. Infrared and VCD mapping of an insulin fibril film has been carried out at both 3 and 1 mm spatial resolution, and lysozyme films were mapped at 1 mm resolution. The IR spectra of different spots vary in intensity due primarily to sample thickness. The changes in the VCD intensity across the map largely correlate to corresponding changes in the IR map. Closer inspection of the insulin map revealed changes in the relative intensities of the VCD spectra not present in the parent IR spectra, which indicated differences in the degree of supramolecular chirality of the fibrils in the various spatial regions. For lysozyme films, in addition to different degrees of supramolecular chirality, reversal of the net fibril chirality was observed. The large signal-to-noise ratio observed at 1 mm resolution implies the feasibility of further increasing the spatial resolution by one or two orders of magnitude for protein fibril film samples.
Department of Chemistry Syracuse University Syracuse NY USA
Institute of Physics Faculty of Mathematics and Physics Charles University Prague Czech Republic
References provided by Crossref.org