Insights into head-column field-amplified sample stacking: Part II. Study of the behavior of the electrophoretic system after electrokinetic injection of cationic compounds across a short water plug
Jazyk angličtina Země Nizozemsko Médium print-electronic
Typ dokumentu časopisecké články
PubMed
28712552
DOI
10.1016/j.chroma.2017.06.073
PII: S0021-9673(17)30963-9
Knihovny.cz E-zdroje
- Klíčová slova
- Capillary electrophoresis, Computer simulation, Electrohydrodynamics, Electrokinetic injection, Head-column field-amplified sample stacking, Water plug,
- MeSH
- elektroforéza kapilární přístrojové vybavení metody MeSH
- elektrolyty chemie MeSH
- elektroosmóza MeSH
- kationty chemie MeSH
- kyseliny fosforečné chemie MeSH
- počítačová simulace MeSH
- pufry MeSH
- voda chemie MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- elektrolyty MeSH
- kationty MeSH
- kyseliny fosforečné MeSH
- phosphoric acid MeSH Prohlížeč
- pufry MeSH
- voda MeSH
Part I on head-column field-amplified sample stacking comprised a detailed study of the electrokinetic injection of a weak base across a short water plug into a phosphate buffer at low pH. The water plug is converted into a low conductive acidic zone and cationic analytes become stacked at the interface between this and a newly formed phosphoric acid zone. The fundamentals of electrokinetic processes occurring thereafter were studied experimentally and with computer simulation and are presented as part II. The configuration analyzed represents a discontinuous buffer system. Computer simulation revealed that the phosphoric acid zone at the plug-buffer interface becomes converted into a migrating phosphate buffer plug which corresponds to the cationically migrating system zone of the phosphate buffer system. Its mobility is higher than that of the analytes such that they migrate behind the system zone in a phosphate buffer comparable to the applied background electrolyte. The temporal behaviour of the current and the conductivity across the water plug were monitored and found to reflect the changes in the low conductivity plug. Determination of the buffer flow in the capillary revealed increased pumping caused by the mismatch of electroosmosis within the low conductivity plug and the buffer. This effect becomes elevated with increasing water plug length. For plug lengths up to 1% of the total column length the flow quickly drops to the electroosmotic flow of the buffer and simulations with experimentally determined current and flow values predict negligible band dispersion and no loss of resolution for both low and large molecular mass components.