The chromatographic behaviour of new double-labelled oligodeoxynucleotide probes containing azaphthalocyanine dye as a quencher with respect to evaluation of their purity

. 2021 Apr ; 35 (4) : e5033. [epub] 20201208

Jazyk angličtina Země Anglie, Velká Británie Médium print-electronic

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid33226652

Grantová podpora
17-19094S Grantová Agentura České Republiky
SVV 260 547 Univerzita Karlova v Praze

The influence of experimental conditions on chromatographic behaviour of promising oligodeoxynucleotide double-labelled molecular probes containing an azaphthalocyanine macrocycle as a perspective dark quencher was studied. A recently introduced new stationary phase based on styrene-divinylbenzene copolymer was tested. The planar and hydrophobic structure of the azaphthalocyanine is considerably different from those of currently used fluorophores and quenchers. Thus, the most challenging issue was the separation of the double-labelled probe from its main impurity represented by a mono-labelled probe, containing only the azaphthalocyanine macrocycle. The absorbance measurement cannot simply determine this impurity, and its presence fundamentally compromises the biological assay. The commonly used gradient elution was not suitable and isocratic conditions seemed to be more appropriate. The azaphthalocyanine moiety influences the properties of the modified oligodeoxynucleotides substantially, and thus their chromatographic behaviour was determined predominantly by this quencher. Acetonitrile was the preferred organic solvent for the analysis of probes containing the azaphthalocyanine quencher and the effect of ion-pairing reagents was dependent on the probe structure. The temperature seemed to be an effective parameter for fine-tuning of the separation and mass transfer improvement. Generally, our findings could be helpful in method development for purity evaluation of double-labelled oligodeoxynucleotide probes and semipreparative methods.

Zobrazit více v PubMed

Apffel, A., Chakel, J. A., Fischer, S., Lichtenwalter, K., & Hancock, W. S. (1997). Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry. Analytical Chemistry, 69(7), 1320-1325. https://doi.org/10.1021/ac960916h

Buncek, M., Backovska, V., Holasova, A., Radilova, H., Safarova, M., Kunc, F., & Haluza, R. (2006). Unusual chromatographic behavior of oligonucleotide sequence isomers on two different anion exchange HPLC columns. Analytical Biochemistry, 348(2), 300-306. https://doi.org/10.1016/j.ab.2005.10.047

Buncek, M., Backovska, V., Holasova, S., Radilova, H., Safarova, M., Kunc, F., & Haluza, R. (2005). Retention behavior of oligonucleotides on a glycidyl methacrylate-based DEAE-modified sorbent. Chromatographia, 62(5-6), 263-269. https://doi.org/10.1365/s10337-005-0620-x

Choi, Y., Ryu, T., Lee, A. C., Choi, H., Lee, H., Park, J., & Kwon, S. (2019). High information capacity DNA-based data storage with augmented encoding characters using degenerate bases. Scientific Reports, 9, 7-7. https://doi.org/10.1038/s41598-019-43105-w

Demuth, J., Kucera, R., Kopecky, K., Havlinova, Z., Libra, A., Novakova, V., & Zimcik, P. (2018). Efficient synthesis of a wide-range absorbing azaphthalocyanine dark quencher and its application to dual-labeled oligonucleotide probes for quantitative real-time polymerase chain reactions. Chemistry-a European Journal, 24(38), 9658-9666. https://doi.org/10.1002/chem.201801319

Demuth, J., Kucera, R., Ruzicka, A., Havlinova, Z., Libra, A., Novakova, V., & Zimcik, P. (2019). Self-assembly of azaphthalocyanine-oligodeoxynucleotide conjugates into J-dimers: Towards biomolecular logic gates. Organic Chemistry Frontiers., 7, 445-456. https://doi.org/10.1039/C9QO01364D

Djordjevic, N. M., Houdiere, F., Fowler, P., & Natt, F. (1998). HPLC separation of oligonucleotides in isocratic and temperature programming mode. Analytical Chemistry, 70(9), 1921-1925. https://doi.org/10.1021/ac9711697

Fountain, K. J., Gilar, M., Budman, Y., & Gebler, J. C. (2003). Purification of dye-labeled oligonucleotides by ion-pair reversed-phase high-performance liquid chromatography. Journal of Chromatography B-Analytical Technologies in the Biomedical and Life Sciences, 783(1), 61-72. https://doi.org/10.1016/s1570-0232(02)00490-7

Fountain, K. J., Gilar, M., & Gebler, J. C. (2003). Analysis of native and chemically modified oligonucleotides by tandem ion-pair reversed-phase high-performance liquid chromatography/electrospray ionization mass spectrometry. Rapid Communications in Mass Spectrometry, 17(7), 646-653. https://doi.org/10.1002/rcm.959

Gilar, M., & Bouvier, E. S. P. (2000). Purification of crude DNA oligonucleotides by solid-phase extraction and reversed-phase high-performance liquid chromatography. Journal of Chromatography a, 890(1), 167-177. https://doi.org/10.1016/s0021-9673(00)00521-5

Gilar, M., Fountain, K. J., Budman, Y., Holyoke, J. L., Davoudi, H., & Gebler, J. C. (2003). Characterization of therapeutic oligonucleotides using liquid chromatography with on-line mass spectrometry detection. Oligonucleotides, 13(4), 229-243. https://doi.org/10.1089/154545703322460612

Gilar, M., Fountain, K. J., Budman, Y., Neue, U. D., Yardley, K. R., Rainville, P. D., & Gebler, J. C. (2002). Ion-pair reversed-phase high-performance liquid chromatography analysis of oligonucleotides: Retention prediction. Journal of Chromatography a, 958(1-2), 167-182. https://doi.org/10.1016/s0021-9673(02)00306-0

Johansson, M. K., Fidder, H., Dick, D., & Cook, R. M. (2002). Intramolecular dimers: A new strategy to fluorescence quenching in dual-labeled oligonucleotide probes. Journal of the American Chemical Society, 124(24), 6950-6956. https://doi.org/10.1021/ja025678o

Kopecky, K., Novakova, V., Miletin, M., Kucera, R., & Zimcik, P. (2010). Solid-phase synthesis of azaphthalocyanine-oligonucleotide conjugates and their evaluation as new dark quenchers of fluorescence. Bioconjugate Chemistry, 21(10), 1872-1879. https://doi.org/10.1021/bc100226x

Kopecky, K., Novakova, V., Miletin, M., Kucera, R., & Zimcik, P. (2011). Synthesis of new azaphthalocyanine dark quencher and evaluation of its quenching efficiency with different fluorophores. Tetrahedron, 67(33), 5956-5963. https://doi.org/10.1016/j.tet.2011.06.038

Lakowicz, J. R. (2006). Principles of fluorescence spectroscopy (3rd ed.). Springer.

Li, Q. Q., Luan, G. Y., Guo, Q. P., & Liang, J. X. (2002). A new class of homogeneous nucleic acid probes based on specific displacement hybridization. Nucleic Acids Research, 30(2), e5-e55. https://doi.org/10.1093/nar/30.2.e5

Livak, K. J., Flood, S. J. A., Marmaro, J., Giusti, W., & Deetz, K. (1995). Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR product and nucleic-acid hybridization. Pcr-Methods and Applications, 4(6), 357-362. https://doi.org/10.1101/gr.4.6.357

Novakova, V., Donzello, M. P., Ercolani, C., Zimcik, P., & Stuzhin, P. A. (2018). Tetrapyrazinoporphyrazines and their metal derivatives. Part II: Electronic structure, electrochemical, spectral, photophysical and other application related properties. Coordination Chemistry Reviews, 361, 1-73. https://doi.org/10.1016/j.ccr.2018.01.015

Oefner, P. J., Huber, C. G., Umlauft, F., Berti, G. N., Stimpfl, E., & Bonn, G. K. (1994). High-resolution liquid-chromatography of fluorescent dye-labeled nucleic-acids. Analytical Biochemistry, 223(1), 39-46. https://doi.org/10.1006/abio.1994.1543

Sixou, S., Szoka, F. C., Green, G. A., Giusti, B., Zon, G., & Chin, D. J. (1994). Intracellular oligonucleotide hybridization detected by fluorescence resonance energy-transfer (FRET). Nucleic Acids Research, 22(4), 662-668. https://doi.org/10.1093/nar/22.4.662

Snyder, L. R., Kirkland, J. J., & Dolan, J. W. (2010). Introduction to modern liquid chromatography (3rd ed.). Wiley.

Studzinska, S., Pietrzak, L., & Buszewski, B. (2014). The effects of stationary phases on retention and selectivity of oligonucleotides in IP-RP-HPLC. Chromatographia, 77(23-24), 1589-1596. https://doi.org/10.1007/s10337-014-2766-x

Studzinska, S., Rola, R., & Buszewski, B. (2017). The impact of ion-pairing reagents on the selectivity and sensitivity in the analysis of modified oligonucleotides in serum samples by liquid chromatography coupled with tandem mass spectrometry. Journal of Pharmaceutical and Biomedical Analysis, 138, 146-152. https://doi.org/10.1016/j.jpba.2017.02.014

ThermoFisher Scientific, (2016). DNAPac RP Columns, Product Manual. Retrieved from https://assets.thermofisher.com/TFS-Assets/CMD/manuals/Man-065679-LC-DNAPac-RP-Man065679-EN.pdf

Tyagi, S., & Kramer, F. R. (1996). Molecular beacons: Probes that fluoresce upon hybridization. Nature Biotechnology, 14(3), 303-308. https://doi.org/10.1038/nbt0396-303

Wilhelm, J., & Pingoud, A. (2003). Real-time polymerase chain reaction. Chembiochem, 4(11), 1120-1128. https://doi.org/10.1002/cbic.200300662

Zhang, H. Q., Li, F., Dever, B., Li, X. F., & Le, X. C. (2013). DNA-mediated homogeneous binding assays for nucleic acids and proteins. Chemical Reviews, 113(4), 2812-2841. https://doi.org/10.1021/cr300340p

Zhou, J. H., & Rossi, J. (2017). Aptamers as targeted therapeutics: Current potential and challenges. Nature Reviews Drug Discovery, 16(3), 181-202. https://doi.org/10.1038/nrd.2016.199

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...