Validation of a single tube 3-colour immature red blood cell screening assay for the detection and enumeration of small, medium and large paroxysmal nocturnal haemoglobinuria clones by flow cytometry
Jazyk angličtina Země Anglie, Velká Británie Médium print-electronic
Typ dokumentu časopisecké články
PubMed
35614534
DOI
10.1111/ijlh.13877
Knihovny.cz E-zdroje
- Klíčová slova
- flow cytometry, immature red blood cells, paroxysmal nocturnal haemoglobinuria, screening assay,
- MeSH
- barva MeSH
- buněčné klony MeSH
- erytrocyty MeSH
- lidé MeSH
- paroxysmální hemoglobinurie * diagnóza MeSH
- průtoková cytometrie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: The reliable diagnosis of paroxysmal nocturnal haemoglobinuria (PNH) by flow cytometry is based on mandatory analysis of the erythroid, neutrophilic and monocytic lineages. In this study, we have evaluated the performance characteristics of a recently published immature red blood cell (iRBC) assay as a potential screening test for PNH by flow cytometry. METHODS: Intra- and inter-assay imprecision were determined in five replicates of small, medium and large PNH iRBC clones. Analytical and functional sensitivity was assessed by performing spiking tests for five replicates. Thirty healthy donors and 441 PNH patients were tested for evaluation of clinical specificity, sensitivity, positive and negative predictive values. RESULTS: Coefficients of variation (CV) for intra-/inter-assay imprecision analyses were 1.31/1.50, 3.19/2.61 and 3.99/1.58 for the big, medium and small clone sizes, respectively. Absolute values (100%) were found for both clinical specificity and sensitivity as well as for both positive and negative predictive values. The CV from 5 replicate results for 10 clustered events was 15.7%. The coefficient of determination (r2 ), Pearson's correlation coefficient (r) and Bland-Altman mean bias were 0.9436/0.9234/1.7 for PNH iRBC compared to PNH neutrophils and 0.9553/0.9387/2.1 for PNH iRBCs compared to PNH monocytes. CONCLUSION: Our results confirm very good performance characteristics, high analytical and functional sensitivity, absolute clinical specificity and sensitivity as well as favourable correlation between PNH iRBCs and both PNH neutrophils and monocytes, suggesting that this cost-effective 3-colour iRBC assay can be used as a reliable screening test for evaluation of small, medium and large PNH clones by flow cytometry.
Clinical Department Institute of Haematology and Blood Transfusion Prague Czech Republic
Dahl Chase Diagnostic Services Bangor Maine USA
Department of Laboratory Medicine Toronto General Hospital Toronto Ontario Canada
Zobrazit více v PubMed
Dacie JV. Paroxysmal nocturnal haemoglobinuria. Proc R Soc Med. 2014;56:587-596.
Oni SB, Osunkoya BO, Luzzatto L. Paroxysmal nocturnal hemoglobinuria: evidence for monoclonal origin of abnormal red cells. Blood. 1970;36:145-152.
Miyata T, Takeda J, Lida Y, et al. The cloning of PIG-A, a component in the early step of GPI- anchor biosynthesis. Science. 1993;259:1318-1320.
Holguin MH, Fredrick LR, Bernshaw NJ, Wilcox LA, Parker CJ. Isolation and characterization of a membrane protein from normal human erythrocytes that inhibits reactive lysis of the erythrocytes of paroxysmal nocturnal hemoglobinuria. J Clin Invest. 1989;84:7-17.
Nafa K, Bessler M, Castro-Malaspina J, et al. The spectrum of somatic mutations in the PIG-A gene in paroxysmal nocturnal hemoglobinuria includes large deletions and small duplications. Blood Cells Mol Dis. 1998;24:370-384.
Parker C, Omine M, Richards S, et al. Diagnosis and management of paroxysmal nocturnal hemoglobinuria. Blood. 2005;106:3699-3709.
Sutherland DR, Kuek N, Davidson J, et al. Diagnosing PNH with FLAER and multipara-meter flow cytometry. Cytometry Part B. 2007;72B:167-177.
Sutherland DR, Keeney M, Illingworth A. Practical guidelines for the high-sensitivity detection and monitoring of paroxysmal nocturnal hemoglobinuria clones by flow cytometry. Cytometry Part B. 2012;82B:195-208.
Sutherland DR, Acton E, Keeney M, Davis BH, Illingworth A. Use of CD157 in FLAER-based assays for high-sensitivity PNH neutrophil and PNH monocyte detection. Cytometry Part B. 2014;86B:44-55.
Sutherland DR, Illingworth A, Marinov I, et al. ICCS/ESCCA consensus guidelines to detect GPI-deficient cells in paroxysmal nocturnal hemoglobinuria (PNH) and related disorders: part 2 - reagent selection and assay optimization for high sensitivity testing. Cytometry Part B. 2018;94B:23-48.
Borowitz MJ, Craig F, DiGiuseppe JA, et al. Guidelines for the diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria and related disorders by flow cytometry-a consensus guideline. Cytometry Part B. 2010;72B:211-230.
Illingworth A, Marinov I, Sutherland DR, Wagner Ballon O, Del Vecchio L. ICCS/ESCCA consensus guidelines to detect GPI-deficient cells in paroxysmal nocturnal hemoglobinuria (PNH) and related disorders: part 3; data analysis, reporting and case studies. Cytometry Part B. 2018;94B:49-66.
Oldaker T, Whitby L, Saber M, Holden J, Wallace PK, Litwin V. ICCS/ESCCA consensus guidelines to detect GPI-deficient cells in paroxysmal nocturnal hemoglobinuria (PNH) and related disorders: part 4 - assay validation and quality assurance. Cytometry Part B. 2018;94B:67-81.
Sutherland DR, Ortiz F, Quest G, et al. High-sensitivity 5-, 6-, and 7-color PNH WBC assays for both canto II and Navios platforms. Cytometry Part B. 2018;94B:637-651.
Ware RE, Rosse WF, Hall SE. Immunophenotypic analysis of IRBCs in paroxysmal nocturnal hemoglobinuria. Blood. 1995;86:1586-1589.
Chin-Yee I, Keeney M, Lohmann RC. Flow cytometric reticulocyte analysis using Thiazole Orange; clinical experience and technical limitations. Clin Lab Hematol. 1996;13:177-188.
Tsagarakis NJ, Paterakis G. A simple flow cytometric assay for routine paroxysmal nocturnal hemoglobinuria testing based on immature reticulocytes and granulocytes monocytes by flow cytometry. Cytometry Part B. 2012;82B:259-263.
Naumova EV, Plekhanova OS, Lugovskaia SA, Bugrov PME, IY. The evaluation and comparative characteristic of detection of clone of paroxysmal nocturnal hemoglobinuria on iRBCs using the technique of flow cytometry. Klin Lab Diagn. 2014;59:25-28.
Sutherland DR, Richards SJ, Ortiz F, et al. CD71 improves delineation of PNH type III, PNH type II, and normal immature RBCS in patients with paroxysmal nocturnal hemoglobinuria. Cytometry Part B. 2020;98(2):179-192.
Marinov I, Kohoutova M, Tkacova V, Pesek A, Cermak J, Cetkovsky P. Clinical relevance of CD157 for rapid and cost-effective simultaneous evaluation of PNH granulocytes and monocytes by flow cytometry. Int Jnl Lab Hem. 2015;37(2):231-237.
Gatti A, Del Vecchio L, Geuna M, Della Porta MG, Brando B. Multicenter validation of a simplified method for paroxysmal nocturnal hemoglobinuria screening. Eur J Haematol. 2017;99(1):27-35.
Sutherland DR, Illingworth A, Whitby L, et al. Eur J Haematol. 2017;101:804-806. doi:10.1111/ejh.12885