Emergency medicine pharmacotherapy compromises accuracy of plasma creatinine determination by enzyme-based methods: real-world clinical evidence and implications for clinical practice

. 2023 ; 10 () : 1236948. [epub] 20240108

Status PubMed-not-MEDLINE Jazyk angličtina Země Švýcarsko Médium electronic-ecollection

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid38259831

BACKGROUND: Assessment of kidney function in emergency settings is essential across all medical subspecialties. Daily assessment of patient creatinine results from emergency medical services showed that some deviated from expected values, implying drug-related interference. METHODS: Real-time clinical evaluation of an enzyme method (Roche CREP2) in comparison with the Jaffé gen. 2 method (Roche CREJ2) was performed. During the period of December 2022 and January 2023, we analyzed 8,498 patient samples, where 5,524 were heavily medicated STAT patient specimens, 500 were pediatric specimens, and 2,474 were from a distant general population in a different region using the same methods. RESULTS: In 109 out of 5,524 hospital specimens (1.97%, p < 0.001), the CREP2 value was apparently (25% or more) lower than CREJ2. Suspect interfering medication was found in a sample of 43 out of 46 reviewed patients where medication data were available. This phenomenon was not observed in the general population. CONCLUSION: In a polymedicated urgent care hospital population, a creatinine enzyme method produces unreliable results, apparently due to multiple drug-related interferences.

Zobrazit více v PubMed

Jaffe M. Ueber den Niederschlag, welchen Pikrinsäure in normalem Harn erzeugt und über eine neue Reaction des Kreatinins. Z Physiol Chem. (1886) 10:391–400.

PubMed

PubMed DOI

PubMed DOI

PubMed DOI

PubMed DOI PMC

PubMed DOI

PubMed DOI

PubMed DOI PMC

PubMed DOI

PubMed DOI

PubMed DOI PMC

Roche Diagnostics Corporation . [Method Sheet] CREP2 "Kreatinin plus 2. verze" [CZ]. no. 0105168589190c701V13.0 [Print]. (2022).

R Core Team . A language and environment for statistical computing. R Foundation for Statistical Computing. (2022). Available at: https://www.R-project.org/.

Wickham H. ggplot2: Elegant graphics for data analysis. New York: Springer-Verlag; (2016).

Rudis B. Hrbrthemes: additional themes, theme components and utilities for 'ggplot2'. R package version 0.8.0. (2020). Available at: https://CRAN.R-project.org/package=hrbrthemes.

PubMed DOI PMC

PubMed DOI PMC

State Institute for Drug Control (SÚKL) . [SmPC] ACC-Injekt Summary of product characteristics [CZ]. sp.zn.sukls315481/2020. Available at: https://www.sukl.cz/modules/medication/download.php?file=SPC175927.pdf&type=spc&as=acc-injekt-spc.

State Institute for Drug Control (SÚKL) . [SmPC] Dicynone-Summary of product characteristics [CZ]. sp.zn. sukls26699/2022. Available at: https://www.sukl.cz/modules/medication/download.php?file=SPC185883.pdf&type=spc&as=dicynone-spc.

State Institute for Drug Control (SÚKL) . [SmPC] Novalgin-Summary of product characteristics [CZ]. sp. zn. sukls39194/2022. Available at: https://www.sukl.cz/modules/medication/download.php?file=SPC184586.pdf&type=spc&as=novalgin-spc.

Roche Diagnostics Corporation . CREP2 "Kreatinin plus 2. verze" [CZ]. no. 0105168589190c701V13.0. (2022).

PubMed DOI PMC

PubMed DOI

PubMed DOI

PubMed DOI

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...