One-Year Clinical Outcomes Following Aspheric Toric Monofocal IOL with a Double C-Loop Haptic Design Implantation

. 2024 ; 18 () : 3515-3525. [epub] 20241128

Status PubMed-not-MEDLINE Jazyk angličtina Země Nový Zéland Médium electronic-ecollection

Typ dokumentu kazuistiky, klinické zkoušky, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid39629057

PURPOSE: This study aimed to evaluate one-year clinical outcomes in cataract patients with pre-existing corneal astigmatism implanted with a biconvex aspheric toric monofocal intraocular lens (IOL) with a double C-loop haptic-design. METHODS: One hundred and eighteen patients (236 eyes) with corneal astigmatism (≥0.75D) were implanted bilaterally with the PODEYE toric IOL and assessed up to 1-year after surgery. Postoperative evaluation included monocular and binocular uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA), under both photopic and mesopic lighting conditions, refraction, photopic and mesopic contrast sensitivity (with and without glare), and rotational stability. RESULTS: At the last postoperative visit, 74.6% and 95.8% of eyes were within ±0.50D and ±1.00D of the target refraction, respectively. About 78.0% and 97.5% of eyes showed a postoperative refractive cylinder of ≤0.50D and ≤1.00D, respectively. The mean manifest spherical equivalent value was 0.16±0.40D, and the mean refractive cylinder value was -0.42±0.33D. 97.5% and 100% of patients had a binocular UDVA and CDVA of ≥20/32, respectively. The mean binocular UDVA and CDVA were 0.01±0.09 and -0.03±0.07 logMAR, respectively. Under mesopic conditions, 79.5% and 89.8% of patients showed a binocular UDVA and CDVA of ≥20/32, respectively. The mean binocular UDVA and CDVA were 0.15±0.11 and 0.10±0.10 logMAR, respectively. Binocular contrast sensitivity function both under photopic and mesopic conditions was good. The mean absolute IOL rotation was 2.52±2.59 degrees with 98.56% of eyes having a rotation of less than 10 degrees. CONCLUSION: Bilateral implantation of an aspheric toric monofocal IOL with a double C-loop haptic design in cataract patients with corneal astigmatism provides good visual and refractive outcomes up to 1-year post-surgery.

Zobrazit více v PubMed

Day AC, Dhariwal M, Keith MS, et al. Distribution of preoperative and postoperative astigmatism in a large population of patients undergoing cataract surgery in the UK. Br J Ophthalmol. 2019;103:993–1000. doi:10.1136/bjophthalmol-2018-312025 PubMed DOI PMC

Villegas EA, Alcon E, Artal P. Minimum amount of astigmatism that should be corrected. J Cataract Refract Surg. 2014;40:13–19. doi:10.1016/j.jcrs.2013.09.010 PubMed DOI

Kessel L, Andresen J, Tendal B, Erngaard D, Flesner P, Hjortdal J. Toric intraocular lenses in the correction of astigmatism during cataract surgery: a systematic review and meta-analysis. Ophthalmology. 2016;123(2):275–286. doi:10.1016/j.ophtha.2015.10.002 PubMed DOI

Chassain C, Hallak MK, Lesaffre M. Rotational stability and clinical outcomes after implantation of a new monofocal toric intraocular lens with double C-loop design. J Fr Ophtalmol. 2023;46:571–580. doi:10.1016/j.jfo.2022.07.005 PubMed DOI

Ang RET, Tañá-Rivero P, Pastor-Pascual F, Stodulka P, Tetz M, Fischinger I. Visual and refractive outcomes after bilateral implantation of a biconvex aspheric toric monofocal intraocular with a double C-loop haptic design. Clin Ophthalmol. 2023;17:2765–2776. doi:10.2147/OPTH.S432598 PubMed DOI PMC

Yen WT, Weng TH, Lin TY, Tai MC, Chen YH, Chang YM. Femtosecond laser-assisted astigmatic keratotomy versus toric IOL implantation for correcting astigmatism in cataract patients: a systematic review and meta-analysis with trial sequential analysis. Br J Ophthalmol. 2024;bjo–2024–325195. doi:10.1136/bjo-2024-325195 PubMed DOI

Goggin M. Toric intraocular lenses: evidence-based use. Clin Exp Ophthalmol. 2022;50(5):481–489. doi:10.1111/ceo.14106 PubMed DOI PMC

Chassain C. Évaluation des performances visuelles aprèsimplantation d’une lentille intraoculaire torique à double anseen C [Evaluation of visual performance after implantation of a double C-Loop toric intraocular lens]. J Fr Ophtalmol. 2014;37:507–513. French. doi:10.1016/j.jfo.2014.02.007 PubMed DOI

Remón L, Cabeza-Gil I, Calvo B, Poyales F, Garzón N. Biomechanical stability of three intraocular lenses with different haptic designs: in silico and in vivo evaluation. J Refract Surg. 2020;36(9):617–624. doi:10.3928/1081597X-20200713-02 PubMed DOI

Li ES, Vanderford EK, Xu Y, Kang PC. Rotational stability of toric intraocular lenses by lens model and haptic design: a systematic review and single-arm meta-analysis. J Cataract Refract Surg. 2024;50:976–984. doi:10.1097/j.jcrs.0000000000001486 PubMed DOI PMC

Németh G. One degree of misalignment does not lead to a 3.3% effect decrease after implantation of a toric intraocular lens. J Cataract Refract Surg. 2020;46(3):482. doi:10.1097/j.jcrs.0000000000000079 PubMed DOI

ISO 11979-7:2018 ophthalmic implants — intraocular lenses — part 7: clinical investigations. 2018. Available from: https://www.iso.org/standard/69038.html. Accessed November 25, 2024.

Lin X, Ma D, Yang J. Insights into the rotational stability of toric intraocular lens implantation: diagnostic approaches, influencing factors and intervention strategies. Front Med. 2024;11:1349496. doi:10.3389/fmed.2024.1349496 PubMed DOI PMC

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...