Degradation of the mechanical properties of poly-lactide-caprolactone-collagen composite for pulmonary artery banding after implantation into a rat's peritoneum
Jazyk angličtina Země Velká Británie, Anglie Médium print-electronic
Typ dokumentu časopisecké články
PubMed
40180532
DOI
10.1016/j.medengphy.2025.104319
PII: S1350-4533(25)00038-4
Knihovny.cz E-zdroje
- Klíčová slova
- Bioresorbable material, Collagen, Degradation, Elasticity, In vivo, L-lactide, Pulmonary artery banding, ε-caprolactone,
- MeSH
- arteria pulmonalis * chirurgie MeSH
- biokompatibilní materiály chemie MeSH
- biomechanika MeSH
- kolagen * chemie metabolismus MeSH
- krysa rodu Rattus MeSH
- mechanické jevy * MeSH
- peritoneum * chirurgie MeSH
- pevnost v tahu MeSH
- polyestery * chemie metabolismus MeSH
- testování materiálů MeSH
- zvířata MeSH
- Check Tag
- krysa rodu Rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- biokompatibilní materiály MeSH
- kolagen * MeSH
- lactide-caprolactone copolymer MeSH Prohlížeč
- polyestery * MeSH
Pulmonary artery banding is a surgical procedure performed when there is a shunt between the left and right ventricle. Its aim is to constrict the lumen of the pulmonary artery by using a band to reduce blood flow to the lungs. In this study, we report the results of investigating the mechanical properties of a composite composed of poly(L-lactide-co-ε-caprolactone) layers and a collagen matrix (PLCL-COLL). PLCL layers were obtained by electrospinning, impregnated with collagen solution, and finally cross-linked to increase the stiffness of the material. Bands of PLCL-COLL were implanted into a rat peritoneum and explanted after 1, 3, and 6 months in vivo. The mechanical properties of the material before and after implantation were determined using uniaxial tensile tests. The same was done with samples of strips prepared from GORE-TEX material. By comparing the results of tensile tests before implantation and after explantation, it was found that PLCL-COLL degrades in the rat's body and that it exhibits a mechanical response showing of elastic modulus values that correspond well to arterial biomechanics (elastic modulus measured in the initial linear region of the deformation was found to be: 4.14 MPa ± 1.11 MPa, 2.34 MPa ± 1.02 MPa, 1.11 MPa ± 0.77 MPa, and 0.88 MPa ± 0.60 MPa before implantation, and 1, 3, and 6 months after implantation respectively). Similar to the elastic modulus, the strength of the PLCL-COLL composite decreased during in vivo exposure (1.32 ± 0.32 MPa, 0.60 ± 0.26 MPa, 0.44 ± 0.11 MPa, and 0.46 ± 0.28 MPa before implantation, and 1, 3, and 6 months after implantation respectively). In our experiments, PLCL-COLL material was always more compliant than GORE-TEX (elastic modulus 34.7 MPa ± 2.06 MPa before implantation, and 9.35 MPa ± 6.80 MPa after implantation). The results suggest that PLCL-COLL could be a suitable candidate for the development of artery banding tapes, and also for further use in cardiovascular surgery.