BACKGROUND + OBJECTIVE:Age-related macular degeneration (AMD) is the most common cause of practical blindness in people over 60 years of age in industrialised countries. We formulated a hypothesis that a group of initial laboratory parameters would be suitable for prediction of prognosis of AMD, allowing for individual modifications in treatment intensity. PATIENTS AND METHODS: 66 patients with dry form of AMD were treated using rheohaemapheresis with an individual follow-up period of more than 5 years. The patients' initial laboratory data was split in two subgroups based on treatment success and analysed using discriminant analysis (analysis of the linear and quadratic models using the automated and interactive step-wise approach) by means of the Systat 13 software. RESULTS: Prediction of prognosis based on the initial laboratory parameters was correct in 79% of unsuccessfully treated patients, allowing for early detection of high-risk patients. With the use of a quadratic model, the prediction was correct in 100% of unsuccessfully treated patients and in 75% of successfully treated patients. CONCLUSION: Implementation of discriminant analysis is a promising method for prediction of prognosis, especially when the patient is at risk of AMD progression, which allows for early and more intensive monitoring and treatment.
PURPOSE: The DTL fibre electrode is commonly used to record the electric potentials elicited by stimulation of the retina. Two positions are commonly used: it is placed either on the cornea along the lower lid or in the conjunctival fornix. The PERG and OPs have previously been examined and compared under both conditions. The aim of this study was to examine the ERG, flicker response and on-off responses with differing electrode positions. METHODS: Before recruitment, all subjects underwent an ophthalmological examination. We enrolled 13 normal control subjects into the study aged 13-64 years, all with a visual acuity of ≥1.0. We recorded scotopic and photopic ERGs, flicker and on-off responses, for both electrode positions. On the first day, one eye had the electrode placed on the cornea along the lower lid and the other eye had it positioned in the conjunctival sac. On a second day, the recordings were repeated with the alternative electrode placements. RESULTS: ERG, on-off and flicker responses were all smaller by between 20 and 25% when the DTL electrode was positioned in the conjunctival sac, compared to when it was positioned on the cornea, as did the scatter in the data points. This indicates that there is no advantage clinically for one or the other placement. CONCLUSIONS: Our results confirm other reports examining the effect of electrode position on electrophysiological potentials. When recording with the DTL electrode, it is important to ensure that it is placed at the same position in repeat recordings or in multicentre trials and that it is stable and does not move during recording.
- MeSH
- dospělí MeSH
- elektrofyziologie metody MeSH
- elektroretinografie metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- mikroelektrody * MeSH
- mladiství MeSH
- mladý dospělý MeSH
- retina fyziologie MeSH
- rohovka fyziologie MeSH
- studie případů a kontrol MeSH
- světelná stimulace metody MeSH
- zraková ostrost MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Several methods are routinely used in the clinic to diagnose and monitor diseases of inner retinal function. In this study, we compare four such methods in patients with diabetes and glaucoma, to determine correlations between their results and to determine which method is most sensitive for detecting disease. METHODS: Twenty control subjects, 12 patients with early glaucoma and eight patients with diabetes mellitus, were enrolled in the study. All underwent four examinations: transient pattern electroretinogram (PERG), multifocal pattern electroretinogram (mfPERG), chromatic contrast threshold measurements (protan and tritan), and blue-on-yellow short-wavelength automated perimetry (SWAP). RESULTS: For the total cohort of 40 subjects, the results show a significant correlation between the amplitudes of the PERG and those of the mfPERG, as well as between the tritan contrast thresholds and the SWAP MD. Furthermore, ROC analyses reveal that colour contrast thresholds could significantly distinguish between the patient and the control group. Glaucoma patients alone could also be distinguished. CONCLUSIONS: We conclude that the methods compared in this study show correlations between their results if they are testing same pathway or underling cells, and that the colour contrast threshold is the most sensitive method to detect early functional deficits in diabetic and glaucoma patients.
- MeSH
- čípky retiny fyziologie MeSH
- citlivost na kontrast fyziologie MeSH
- diabetes mellitus 1. typu diagnóza patofyziologie MeSH
- diabetická retinopatie diagnóza patofyziologie MeSH
- dospělí MeSH
- elektrofyziologické jevy MeSH
- elektrofyziologie metody MeSH
- elektroretinografie metody MeSH
- glaukom diagnóza patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- poruchy barevného vidění diagnóza patofyziologie MeSH
- ROC křivka MeSH
- senioři MeSH
- senzorické prahy MeSH
- testy zrakového pole MeSH
- zraková pole fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
PURPOSE: To evaluate the experience with rheohaemapheresis (RH) in the treatment of age-related macular degeneration (AMD). METHODS: Thirty-eight patients were each treated with 8 procedures of RH (14 males, 24 females). The control group consisted of 34 random patients (30 females, 4 males) with the dry form of AMD but not treated by RH. Our modification of the cascade method (named rheohaemapheresis) was used for plasma separation. After plasma separation (blood cell separator, Cobe Spectra, Denver, CO, USA), the separated plasma was pumped through a rheofilter (Evaflux 4A, Kuraray, Osaka, Japan) to remove lipoproteins and other high-molecular-weight rheologic factors. RESULTS: In treated patients, best-corrected visual acuity (BCVA) increased significantly from 0.61 (0.06-1.00) to 0.68 (0.35-1.00) after 2.5 years (p = 0.035). We found no significant changes or differences in scotopic activity, whereas cone response and paramacular activity in the more peripheral region between 14° and 22° of eccentricity were significantly higher in treated patients after 2.5 years. CONCLUSION: RH therapy favourably influenced BCVA. During 2.5 years after the therapy, no progression of dry to wet AMD was observed in our patients. RH reduced the area of drusenoid retinal pigment epithelium detachment (which increased during the natural course of dry form AMD). RH influenced rheological markers and probably improved metabolism in the affected retinal areas which lead to the aforementioned positive results.
- MeSH
- biologické markery krev MeSH
- časové faktory MeSH
- elektroretinografie MeSH
- lidé MeSH
- lipoproteiny krev MeSH
- makulární degenerace krev diagnóza patofyziologie terapie MeSH
- noční vidění MeSH
- obnova funkce MeSH
- optická koherentní tomografie MeSH
- prediktivní hodnota testů MeSH
- progrese nemoci MeSH
- reologie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- separace krevních složek metody MeSH
- viskozita krve MeSH
- výsledek terapie MeSH
- zraková ostrost MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Česká republika MeSH
OBJECTIVE: To present a single case report on successful radiotherapy treatment of lacrimal gland infiltration in patient with Sjögren΄s syndrome. BACKGROUND: Radiotherapy is occasionally used for the treatment of benign disorders. There is no report on use of radiotherapy for local treatment of the Sjögren΄s syndrome in the literature. METHODS: Female patient with lacrimal gland involvement as a part of Sjögren΄s syndrome with diplopia and visus deterioration was treated by radiotherapy with eye shielding. RESULTS: Regression of the infiltration with full restoration of visus and minimal acute radiation reaction was achieved. CONCLUSION: A case report of successful use of local radiotherapy in the treatment of lacrimal gland affected by Sjögren΄s syndrome is presented (Fig. 3, Ref. 6). Full Text in PDF www.elis.sk.
- MeSH
- dospělí MeSH
- lidé MeSH
- nemoci slzného ústrojí radioterapie MeSH
- Sjögrenův syndrom radioterapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
- práce podpořená grantem MeSH