Objective.The aim of this study is to create a database for the development, evaluation and objective comparison of algorithms for P wave detection in ECG signals.BrnoUniversity ofTechnology ECG SignalDatabase with Annotations ofP-Wave (BUT PDB) is an ECG signal database with marked peaks of P waves annotated by ECG experts. Currently, there are only a few databases of pathological ECG signals with P-wave annotations, and some are incorrect.Approach.The pathological ECG signals used in this work were selected from three existing databases of ECG signals: MIT-BIH Arrhythmia Database, MIT-BIH Supraventricular Arrhythmia Database and Long Term AF Database. The P-wave positions were manually annotated by two ECG experts in all selected signals.Main results.The final BUT PDB composed of selected signals consists of 50 two-minute, two-lead pathological ECG signal records with annotated P waves. Each record also contains a description of the diagnosis (pathology) present in the selected part of the record and information about positions and types of QRS complexes.Significance.The BUT PDB is created for developing new, more accurate and robust methods for P wave detection. These algorithms will be used in medical practice and will help cardiologists to evaluate ECG records, establish diagnoses and save time.
Accurate automated detection of P waves in ECG allows to provide fast correct diagnosis of various cardiac arrhythmias and select suitable strategy for patients' treatment. However, P waves detection is a still challenging task, especially in long-term ECGs with manifested cardiac pathologies. Software tools used in medical practice usually fail to detect P waves under pathological conditions. Most of recently published approaches have not been tested on such the signals at all. Here we introduce a novel method for accurate and reliable P wave detection, which is success in both normal and pathological cases. Our method uses phasor transform of ECG and innovative decision rules in order to improve P waves detection in pathological signals. The rules are based on a deep knowledge of heart manifestation during various arrhythmias, such as atrial fibrillation, premature ventricular contraction, etc. By involving the rules into the decision process, we are able to find the P wave in the correct location or, alternatively, not to search for it at all. In contrast to another studies, we use three, highly variable annotated ECG databases, which contain both normal and pathological records, to objectively validate our algorithm. The results for physiological records are Se = 98.56% and PP = 99.82% for MIT-BIH Arrhythmia Database (MITDP, with MITDB P-Wave Annotations) and Se = 99.23% and PP = 99.12% for QT database. These results are comparable with other published methods. For pathological signals, the proposed method reaches Se = 96.40% and PP = 91.56% for MITDB and Se = 93.07% and PP = 88.60% for Brno University of Technology ECG Signal Database with Annotations of P wave (BUT PDB). In these signals, the proposed detector greatly outperforms other methods and, thus, represents a huge step towards effective use of fully automated ECG analysis in a real medical practice.
To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10-second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user-friendly, cheap, on-the-spot, self-home-monitoring of heart rate with the potential of widespread using.
- MeSH
- algoritmy MeSH
- artefakty MeSH
- chytrý telefon MeSH
- databáze faktografické * MeSH
- dospělí MeSH
- elektrokardiografie MeSH
- fotopletysmografie statistika a číselné údaje MeSH
- lidé středního věku MeSH
- lidé MeSH
- počítačové zpracování signálu přístrojové vybavení MeSH
- referenční hodnoty MeSH
- referenční standardy MeSH
- srdeční frekvence fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- dataset MeSH
- Geografické názvy
- Česká republika MeSH
The performance of ECG signals compression is influenced by many things. However, there is not a single study primarily focused on the possible effects of ECG pathologies on the performance of compression algorithms. This study evaluates whether the pathologies present in ECG signals affect the efficiency and quality of compression. Single-cycle fractal-based compression algorithm and compression algorithm based on combination of wavelet transform and set partitioning in hierarchical trees are used to compress 125 15-leads ECG signals from CSE database. Rhythm and morphology of these signals are newly annotated as physiological or pathological. The compression performance results are statistically evaluated. Using both compression algorithms, physiological signals are compressed with better quality than pathological signals according to 8 and 9 out of 12 quality metrics, respectively. Moreover, it was statistically proven that pathological signals were compressed with lower efficiency than physiological signals. Signals with physiological rhythm and physiological morphology were compressed with the best quality. The worst results reported the group of signals with pathological rhythm and pathological morphology. This study is the first one which deals with effects of ECG pathologies on the performance of compression algorithms. Signal-by-signal rhythm and morphology annotations (physiological/pathological) for the CSE database are newly published.
- MeSH
- algoritmy MeSH
- databáze faktografické MeSH
- elektrokardiografie metody MeSH
- fraktály MeSH
- komprese dat metody MeSH
- lidé MeSH
- vlnková analýza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Compression of ECG signal is essential especially in the area of signal transmission in telemedicine. There exist many compression algorithms which are described in various details, tested on various datasets and their performance is expressed by different ways. There is a lack of standardization in this area. This study points out these drawbacks and presents new compression algorithm which is properly described, tested and objectively compared with other authors. This study serves as an example how the standardization should look like. Single-cycle fractal-based (SCyF) compression algorithm is introduced and tested on 4 different databases-CSE database, MIT-BIH arrhythmia database, High-frequency signal and Brno University of Technology ECG quality database (BUT QDB). SCyF algorithm is always compared with well-known algorithm based on wavelet transform and set partitioning in hierarchical trees in terms of efficiency (2 methods) and quality/distortion of the signal after compression (12 methods). Detail analysis of the results is provided. The results of SCyF compression algorithm reach up to avL = 0.4460 bps and PRDN = 2.8236%.
Reliable P wave detection is necessary for accurate and automatic electrocardiogram (ECG) analysis. Currently, methods for P wave detection in physiological conditions are well-described and efficient. However, methods for P wave detection during pathology are not generally found in the literature, or their performance is insufficient. This work introduces a novel method, based on a phasor transform, as well as innovative rules that improve P wave detection during pathology. These rules are based on the extraction of a heartbeats' morphological features and knowledge of heart manifestation during both physiological and pathological conditions. To properly evaluate the performance of the proposed algorithm in pathological conditions, a standard database with a sufficient number of reference P wave positions is needed. However, such a database did not exist. Thus, ECG experts annotated 12 chosen pathological records from the MIT-BIH Arrhythmia Database. These annotations are publicly available via Physionet. The algorithm performance was also validated using physiological records from the MIT-BIH Arrhythmia and QT databases. The results for physiological signals were Se = 98.42% and PP = 99.98%, which is comparable to other methods. For pathological signals, the proposed method reached Se = 96.40% and PP = 85.84%, which greatly outperforms other methods. This improvement represents a huge step towards fully automated analysis systems being respected by ECG experts. These systems are necessary, particularly in the area of long-term monitoring.
Bioinformatics may seem to be a scientific field processing primarily large string datasets, as nucleotides and amino acids are represented with dedicated characters. On the other hand, many computational tasks that bioinformatics challenges are mathematical problems understandable as operations with digits. In fact, many computational tasks are solved this way in the background. One of the most widely used digital representations is mapping of nucleotides and amino acids with integers 0-3 and 0-20, respectively. The limitation of this mapping occurs when the digital signal of nucleotides has to be translated into a digital signal of amino acids as the genetic code is degenerated. This causes non-monotonies in a mapping function. Although map for reducing this undesirable effect has already been proposed, it is defined theoretically and for standard genetic codes only. In this study, we derived a novel optimal criterion for reducing the influence of degeneration by utilizing a large dataset of real sequences with various genetic codes. As a result, we proposed a new robust global optimal map suitable for any genetic code as well as specialized optimal maps for particular genetic codes.
- Publikační typ
- časopisecké články MeSH
Large-scale comparative studies of DNA fingerprints prefer automated chip capillary electrophoresis over conventional gel planar electrophoresis due to the higher precision of the digitalization process. However, the determination of band sizes is still limited by the device resolution and sizing accuracy. Band matching, therefore, remains the key step in DNA fingerprint analysis. Most current methods evaluate only the pairwise similarity of the samples, using heuristically determined constant thresholds to evaluate the maximum allowed band size deviation; unfortunately, that approach significantly reduces the ability to distinguish between closely related samples. This study presents a new approach based on global multiple alignments of bands of all samples, with an adaptive threshold derived from the detailed migration analysis of a large number of real samples. The proposed approach allows the accurate automated analysis of DNA fingerprint similarities for extensive epidemiological studies of bacterial strains, thereby helping to prevent the spread of dangerous microbial infections.
- Publikační typ
- časopisecké články MeSH
Species delineation based on bacterial genomes is an essential part of the research of prokaryotes. In silico genome-to-genome comparison methods are computationally demanding, but much less tedious and error prone than the wet-lab methods. In this paper, we present a novel method for the delineation of bacterial genomes based on genomic signal processing. The proposed method uses numerical representations of whole bacterial genomes, phase signal and cumulated phase signal, from which four parameters are derived for each genome. The parameters characterize a genome and their calculation is independent of the other genomes comprising a delineation dataset. The delineation itself is processed as a calculation of the parameters' average similarity. The method was statistically verified on 1826 bacterial genomes. A similarity threshold of 96% was set based on the receiver operating characteristic curve that featured sensitivity of 99.78% and specificity of 97.25%. Additionally, comparative analysis on another 33 bacterial genomes was conducted using standard delineation tools as these tools were not able to process the dataset of 1826 genomes using desktop computer. The proposed method achieved comparable or better delineation results in comparison with the standard tools. Besides the excellent delineation results, another great advantage of the method is its small computational demands, which enables the delineation of thousands of genomes on a desktop computer. The calculation of the parameters takes tens of minutes for thousands of genomes. Moreover, they can be calculated in advance by creating a database, meaning the delineation itself is then completed in a matter of seconds.
- Publikační typ
- časopisecké články MeSH
OBJECTIVE: Use of wearable ECG devices for arrhythmia screening is limited due to poor signal quality, small number of leads and short records, leading to incorrect recognition of pathological events. This paper introduces a novel approach to classification (normal/'N', atrial fibrillation/'A', other/'O', and noisy/'P') of short single-lead ECGs recorded by wearable devices. APPROACH: Various rhythm and morphology features are derived from the separate beats ('local' features) as well as the entire ECGs ('global' features) to represent short-term events and general trends respectively. Various types of atrial and ventricular activity, heart beats and, finally, ECG records are then recognised by a multi-level approach combining a support vector machine (SVM), decision tree and threshold-based rules. MAIN RESULTS: The proposed features are suitable for the recognition of 'A'. The method is robust due to the noise estimation involved. A combination of radial and linear SVMs ensures both high predictive performance and effective generalisation. Cost-sensitive learning, genetic algorithm feature selection and thresholding improve overall performance. The generalisation ability and reliability of this approach are high, as verified by cross-validation on a training set and by blind testing, with only a slight decrease of overall F1-measure, from 0.84 on training to 0.81 on the tested dataset. 'O' recognition seems to be the most difficult (test F1-measures: 0.90/'N', 0.81/'A' and 0.72/'O') due to high inter-patient variability and similarity with 'N'. SIGNIFICANCE: These study results contribute to multidisciplinary areas, focusing on creation of robust and reliable cardiac monitoring systems in order to improve diagnosis, reduce unnecessary time-consuming expert ECG scoring and, consequently, ensure timely and effective treatment.
- MeSH
- elektrokardiografie přístrojové vybavení metody MeSH
- fibrilace síní diagnóza MeSH
- lidé MeSH
- nositelná elektronika * MeSH
- reprodukovatelnost výsledků MeSH
- rozhodovací stromy MeSH
- support vector machine * MeSH
- určení tepové frekvence přístrojové vybavení metody MeSH
- víceúrovňová analýza MeSH
- vlnková analýza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH