Nejvíce citovaný článek - PubMed ID 28506916
2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation
Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .
- MeSH
- fibrilace síní * chirurgie terapie MeSH
- jednoduchá slepá metoda MeSH
- katetrizační ablace * metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- recidiva MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
AIMS: Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS: FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION: In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION: Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).
- Klíčová slova
- Atrial fibrillation, Paroxysmal atrial fibrillation, Pentaspline PFA catheter, Pulsed field ablation,
- MeSH
- antiarytmika MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- píštěle * chirurgie MeSH
- prospektivní studie MeSH
- recidiva MeSH
- senioři MeSH
- stenóza chirurgie MeSH
- tachykardie chirurgie MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Názvy látek
- antiarytmika MeSH
AIMS: Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility. METHODS AND RESULTS: In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF. CONCLUSION: Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.
- Klíčová slova
- Basket catheter, Electrographic flow mapping, Panoramic mapping, Persistent atrial fibrillation,
- MeSH
- epidermální růstový faktor MeSH
- fibrilace síní * diagnóza chirurgie MeSH
- katetrizační ablace * metody MeSH
- lidé MeSH
- reprodukovatelnost výsledků MeSH
- srdeční síně MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- epidermální růstový faktor MeSH
BACKGROUND: Endocardial catheter ablation (CA) has limited long-term benefit for persistent and longstanding persistent atrial fibrillation (PersAF/LSPAF). We hypothesized hybrid epicardial-endocardial ablation (HA) would have superior effectiveness compared to CA, including repeat (rCA), in PersAF/LSPAF. METHODS: CEASE-AF (NCT02695277) is a prospective, multi-center, randomized controlled trial. Nine hospitals in Poland, Czech Republic, Germany, United Kingdom, and the Netherlands enrolled eligible participants with symptomatic, drug refractory PersAF and left atrial diameter (LAD) > 4.0 cm or LSPAF. Randomization was 2:1 to HA or CA by an independent statistician and stratified by site. Treatment assignments were masked to the core rhythm monitoring laboratory. For HA, pulmonary veins (PV) and left posterior atrial wall were isolated with thoracoscopic epicardial ablation including left atrial appendage exclusion. Endocardial touch-up ablation was performed 91-180 days post-index procedure. For CA, endocardial PV isolation and optional substrate ablation were performed. rCA was permitted between days 91-180. Primary effectiveness was freedom from AF/atrial flutter/atrial tachycardia >30-s through 12-months absent class I/III anti-arrhythmic drugs except those not exceeding previously failed doses. It was assessed in the modified intention-to-treat (mITT) population who had the index procedure and follow-up data. Major complications were assessed in the ITT population who had the index procedure. Thirty-six month follow-up continues. FINDINGS: Enrollment began November 20, 2015 and ended May 22, 2020. In 154 ITT patients (102 HA; 52 CA), 75% were male, mean age was 60.7 ± 7.9 years, mean LAD was 4.7 ± 0.4 cm, and 81% had PersAF. Primary effectiveness was 71.6% (68/95) in HA versus 39.2% (20/51) in CA (absolute benefit increase: 32.4% [95% CI 14.3%-48.0%], p < 0.001). Major complications through 30-days after index procedures plus 30-days after second stage/rCA were similar (HA: 7.8% [8/102] versus CA: 5.8% [3/52], p = 0.75). INTERPRETATION: HA had superior effectiveness compared to CA/rCA in PersAF/LSPAF without significant procedural risk increase. FUNDING: AtriCure, Inc.
BACKGROUND: Electrographic flow (EGF) mapping enables the dynamic detection of functional or active atrial fibrillation (AF) sources outside the pulmonary veins (PVs), and the presence or absence of these sources offers a novel framework for classifying and treating persistent AF patients based on the underlying pathophysiology of their AF disease. OBJECTIVE: The primary objective of the FLOW-AF trial is to evaluate the reliability of the EGF algorithm technology (Ablamap software) to identify AF sources and guide ablation therapy in patients with persistent AF. METHODS: The FLOW-AF trial (NCT04473963) is a prospective, multicenter, randomized clinical study in which patients with persistent or long-standing persistent AF who have failed prior PV isolation (PVI) undergo EGF mapping after confirmation of intact PVI. In total, 85 patients will be enrolled and stratified based on the presence or absence of EGF-identified sources. Patients with an EGF-identified source above the predetermined activity threshold of ≥26.5% will be randomized in a 1:1 fashion to PVI only vs PVI + ablation of EGF-identified extra-PV sources of AF. RESULTS: The primary safety endpoint is freedom from serious adverse events related to the procedure through 7 days following the randomization procedure; and the primary effectiveness endpoint is the successful elimination of significant sources of excitation with the target parameter the activity of the leading source. CONCLUSIONS: The FLOW-AF trial is a randomized study designed to evaluate the ability of the EGF mapping algorithm to identify patients with active extra-PV AF sources.
- Klíčová slova
- Ablation, Ablation outcomes, Atrial fibrillation, Electrographic flow mapping, Sources,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Catheter ablation (CA) technology development reflects the need to improve the effectiveness of atrial fibrillation (AF) treatment. Recently, the DiamondTemp Ablation (DTA) RF generator software was updated with a more responsive power ramp. METHODS: DIAMOND FASTR-AF was a prospective, single-arm, multicenter trial. This study sought to characterize the performance of the updated DTA system for the treatment of patients with drug-refractory paroxysmal and persistent AF (PAF and PsAF). The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence following a 90-day blanking period through 12 months, and the primary safety endpoint was a composite of serious adverse events. RESULTS: In total, 60 subjects (34 PAF and 26 PsAF) underwent CA at three centers. Patients were 71.7% male, (age 63.9 ± 10.2 years, with an AF diagnosis duration 3.1 ± 3.9 years and left atrial size 4.4 ± 0.8 cm). Pulmonary vein isolation-only ablation strategy was performed in 34 (56.7%) subjects. The procedural characteristics show a procedure time 90.8 ± 31.6 min, total RF time 14.7 ± 7.7 min, ablation duration 10.7 ± 3.6 s, and fluid infusion 284.7 ± 111.5 ml. The serious adverse event rate was 8.3% (5/60), 3 pulmonary edema and 2 extended hospitalizations. Freedom from atrial arrhythmia recurrence was achieved in 67.6% of subjects by 12 months. CONCLUSIONS: The updated DTA system demonstrated long-term safety and effectiveness through 12 months of post-ablation follow-up for patients with atrial fibrillation. Additionally, procedures were demonstrated to be highly efficient with short procedure times and low levels of fluid infusion. TRIAL REGISTRATION: Sponsored by Medtronic, Inc.; FASTR-AF ClinicalTrials.gov; NCT03626649.
- Klíčová slova
- Atrial fibrillation, Catheter ablation, DiamondTemp, Radiofrequency,
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- recidiva MeSH
- senioři MeSH
- teplota MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
AIMS: Edoxaban is a direct factor Xa inhibitor approved for stroke prevention in atrial fibrillation (AF). Uninterrupted edoxaban therapy in patients undergoing AF ablation has not been tested. METHODS AND RESULTS: The ELIMINATE-AF trial, a multinational, multicentre, randomized, open-label, parallel-group study, was conducted to assess the safety and efficacy of once-daily edoxaban 60 mg (30 mg in patients indicated for dose reduction) vs. vitamin K antagonists (VKAs) in AF patients undergoing catheter ablation. Patients were randomized 2:1 to edoxaban vs. VKA. The primary endpoint (per-protocol population) was time to first occurrence of all-cause death, stroke, or International Society of Thrombosis and Haemostasis-defined major bleeding during the period from the end of the ablation procedure to end of treatment (90 days). Overall, 632 patients were enrolled, 614 randomized, and 553 received study drug and underwent ablation; 177 subjects underwent brain magnetic resonance imaging to assess silent cerebral infarcts. The primary endpoint (only major bleeds occurred) was observed in 0.3% (1 patient) on edoxaban and 2.0% (2 patients) on VKA [hazard ratio (95% confidence interval): 0.16 (0.02-1.73)]. In the ablation population (modified intent-to-treat population including patients with ablation), the primary endpoint was observed in 2.7% of edoxaban (N = 10) and 1.7% of VKA patients (N = 3) between start of ablation and end of treatment. There were one ischaemic and one haemorrhagic stroke, both in patients on edoxaban. Cerebral microemboli were detected in 13.8% (16) patients who received edoxaban and 9.6% (5) patients in the VKA group (nominal P = 0.62). CONCLUSION: Uninterrupted edoxaban therapy represents an alternative to uninterrupted VKA treatment in patients undergoing AF ablation.
- Klíčová slova
- Ablation, Anticoagulation, Atrial fibrillation, Bleeding events, Stroke,
- MeSH
- cerebrální krvácení chemicky indukované diagnostické zobrazování epidemiologie MeSH
- cévní mozková příhoda epidemiologie prevence a kontrola MeSH
- fibrilace síní epidemiologie chirurgie MeSH
- inhibitory faktoru Xa terapeutické užití MeSH
- katetrizační ablace * MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- pooperační krvácení chemicky indukované epidemiologie MeSH
- pyridiny terapeutické užití MeSH
- senioři MeSH
- thiazoly terapeutické užití MeSH
- vitamin K antagonisté a inhibitory MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- Názvy látek
- edoxaban MeSH Prohlížeč
- inhibitory faktoru Xa MeSH
- pyridiny MeSH
- thiazoly MeSH
- vitamin K MeSH
Patients with atrial fibrillation (AF) are at an approximately 0.5% to 3% increased risk of thromboembolism during and immediately after catheter ablation. Treatment guidelines recommend periprocedural oral anticoagulation plus unfractionated heparin during ablation. Rivaroxaban and dabigatran are the only non-vitamin K oral anticoagulants for which there are randomized controlled trials assessing uninterrupted anticoagulation in patients undergoing catheter ablation of AF. Edoxaban, a direct factor Xa inhibitor, is noninferior vs warfarin for the prevention of stroke or systemic embolism with less major bleeding in patients with nonvalvular AF. The ELIMINATE-AF (Evaluation of Edoxaban Compared With VKA in Subjects Undergoing Catheter Ablation of Nonvalvular Atrial Fibrillation) trial is a multinational, multicenter, prospective, randomized, open-label, parallel-group, blinded-endpoint evaluation (PROBE) study to assess the safety and efficacy of once-daily edoxaban 60 mg (30 mg in patients indicated for a dose reduction) vs vitamin K antagonists (VKA) in patients with nonvalvular AF undergoing catheter ablation (http://www.ClinicalTrials.gov: NCT02942576). A total of 560 patients are planned for randomization to edoxaban or VKA (2:1 ratio) to obtain 450 patients fully compliant with the protocol. Patients will complete 21 to 28 days of anticoagulation prior to the ablation and a 90-day post-ablation period. The primary efficacy endpoint is the composite of all-cause death, stroke, and major bleeding. The primary safety endpoint is major bleeding. A magnetic resonance imaging substudy will assess the incidence of silent cerebral lesions post-ablation. ELIMINATE-AF will define the efficacy and safety of edoxaban for uninterrupted oral anticoagulation during catheter ablation of AF.
- Klíčová slova
- Atrial Fibrillation, Catheter Ablation, Direct Oral Anticoagulant, Direct Oral Anticoagulant Edoxaban, Non-Vitamin K Oral Anticoagulants, Periprocedural,
- MeSH
- antikoagulancia aplikace a dávkování škodlivé účinky MeSH
- časové faktory MeSH
- cévní mozková příhoda diagnostické zobrazování etiologie prevence a kontrola MeSH
- fibrilace síní komplikace mortalita patofyziologie chirurgie MeSH
- inhibitory faktoru Xa aplikace a dávkování škodlivé účinky MeSH
- ischemie mozku diagnostické zobrazování etiologie prevence a kontrola MeSH
- katetrizační ablace * škodlivé účinky mortalita MeSH
- klinické protokoly MeSH
- krvácení chemicky indukované MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- prospektivní studie MeSH
- pyridiny aplikace a dávkování škodlivé účinky MeSH
- rizikové faktory MeSH
- rozvrh dávkování léků MeSH
- thiazoly aplikace a dávkování škodlivé účinky MeSH
- vitamin K antagonisté a inhibitory MeSH
- výsledek terapie MeSH
- výzkumný projekt MeSH
- warfarin aplikace a dávkování škodlivé účinky MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
- Názvy látek
- antikoagulancia MeSH
- edoxaban MeSH Prohlížeč
- inhibitory faktoru Xa MeSH
- pyridiny MeSH
- thiazoly MeSH
- vitamin K MeSH
- warfarin MeSH