EuroFlow standardization Dotaz Zobrazit nápovědu
EuroFlow Quality Assessment was designed to provide a feedback on the quality of the standardization effort in executing the EuroFlow protocols for sample preparation and instrument setup. It was first beta-tested by the members of the EuroFlow consortium internally (2010-2013) and opened to the external participants from 2015 onwards. The goal of participation in the EuroFlow QA is to evaluate whether the technical quality of the data generated by the laboratory is comparable to the data of the EuroFlow members and thus if a non-EuroFlow member participant can use the EuroFlow reference sample database for his own patient evaluation. Also it assesses whether data are sufficiently standardized for automated population gating and alarm notification. By spring 2018, a total 87 laboratories from 32 countries on five continents have registered for the EuroFlow QA program. We evaluated 163 results of 2015-2016 QA rounds, where we noted clear improvement in the score of first-time participants (median score of 91% correct) when they participated second time or later (median score of 94% correct, p = 0,017), which was comparable to EuroFlow member scores (median score of 97% correct). Among frequent mistakes, we found non-adherence to the EuroFlow protocols (improper reagent used), improper gating and some compensation issues. In summary, we show that EuroFlow QA has a positive impact on improvement of standardized data quality of non-member laboratories adhering to the EuroFlow standard operating procedures and reagent panels.
- Klíčová slova
- EuroFlow, Flow cytometry, Quality assessment scheme, Standardization,
- MeSH
- laboratoře normy MeSH
- lidé MeSH
- průtoková cytometrie normy MeSH
- referenční standardy MeSH
- testování odbornosti laboratoří metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database.
- MeSH
- hematologické nádory diagnóza imunologie MeSH
- imunofenotypizace normy MeSH
- laboratoře normy MeSH
- lidé MeSH
- monoklonální protilátky MeSH
- nádorové biomarkery imunologie MeSH
- prognóza MeSH
- průtoková cytometrie přístrojové vybavení metody normy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Geografické názvy
- Evropa MeSH
- Názvy látek
- monoklonální protilátky MeSH
- nádorové biomarkery MeSH
This commentary discusses particularities of application of the EuroFlow standardization of flow cytometric analyses on three different flow cytometers. The EuroFlow consortium developed a fully standardized approach for flow cytometric immunophenotyping of hematological malignancies and primary immunodeficiencies. Standardized instrument setup is an essential part of EuroFlow standardization. Initially, the EuroFlow Consortium developed and optimized a step-by-step standard operating procedure (SOP) to setup 8-color BD FACSCanto II flow cytometer (Canto), with the later inclusion of Navios (Beckman Coulter) and BD FACSLyric (Lyric). Those SOPs were developed to enable standardized and fully comparable fluorescence measurements in the three flow cytometers. In Canto and Navios, mean fluorescence intensity (MFI) of a reference peak of Rainbow beads calibration particles is used to set up photomultiplier (PMT) voltages for each detector channel in individual instruments to reach the same MFI across distinct instruments. In turn, a new feature of Lyric instruments allows to share collection of attributes that are used to place the positive population at the same position among instruments in the form of assays, as one of its components integrated in the Cytometer Setup and Tracking (CS&T) module. The EuroFlow Lyric assays thus allow for standardized acquisition of 8-color EuroFlow panels on Lyric without the need to setup the PMT voltages on the individual instruments manually. In summary, the standardized instrument setup developed by EuroFlow enables cross-platform inter- and intra-laboratory standardization of flow cytometric measurements. This commentary provides a perspective on the modifications of the standardized EuroFlow instrument setup of Canto, Navios and Lyric instruments that are described in detail in individual instrument-specfic SOPs available at the EuroFlow website.
- Klíčová slova
- BD FACSLyric, EuroFlow, Flow cytometry, Instrument setup, Navios, Standardization,
- MeSH
- imunofenotypizace přístrojové vybavení normy MeSH
- lidé MeSH
- průtoková cytometrie přístrojové vybavení normy MeSH
- referenční standardy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
There is an agreement in the field that interlaboratory reproducibility of flow cytometry measurements as well as the whole studies might be improved by a consensual use of methodological approach. Typically, a consensus is made on a crucial markers needed in the immunostaining panel, sometimes on the particular fluorochrome conjugates and rarely on a complete set of methods for sample preparation. The term "standardization" is used to describe the complete set of methodical steps, while "harmonization" is used for partial agreement on the method. Standardization can provide a platform for improved reproducibility of cytometry results over prolonged periods of time, across different sites and across different instruments. For the purpose of structured discussion, several desired aims are described: common interpretation of the immunophenotype definition of a target subset, accurate quantification, reproducible pattern of a multicolor immunophenotype, and reproducible intensity of all measured parameters. An overview of how standardization was approached by several large consortia is provided: EuroFlow, The ONE Study, Human Immunology Project Consortium (HIPC), and several other groups. Their particular aims and the tools adopted to reach those aims are noted. How those standardization efforts were adopted in the field and how the resulting outcome was evaluated is reviewed. Multiple challenges in the instrument hardware design, instrument setup tools, reagent design, and quality features need to be addressed to achieve optimal standardization. Furthermore, the aims of different studies vary, and thus, the reasonable requirements for standardization differ. A framework of reference for the reasonable outcomes of different approaches is offered. Finally, it is argued that complete standardization is important not only for the reproducibility of measurements but also for education, for quality assessment and for algorithmic data analysis. The different standardized approaches can and in fact should serve as benchmarking reference tools for the development of future flow cytometry studies. © 2019 International Society for Advancement of Cytometry.
- Klíčová slova
- EuroFlow, data analysis, flow cytometry, standardization,
- MeSH
- imunofenotypizace MeSH
- indikátory a reagencie MeSH
- lidé MeSH
- průtoková cytometrie * MeSH
- referenční standardy MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Názvy látek
- indikátory a reagencie MeSH
A critical component of the EuroFlow standardization of leukemia/lymphoma immunophenotyping is instrument setup. Initially, the EuroFlow consortium developed a step-by-step standard operating protocol for instrument setup of ≥8-color flow cytometers that were available in 2006, when the EuroFlow activities started. Currently, there are 14 instruments from 9 manufacturers capable of 3-laser excitation and ≥8 color measurements. The specific adaptations required in the instrument set-up to enable them to acquire the standardized 8-color EuroFlow protocols are described here. Overall, all 14 instruments can be fitted with similar violet, blue and red lasers for simultaneous measurements of ≥8 fluorescent dyes. Since individual instruments differ both on their dynamic range (scale) and emission filters, it is not accurate to simply recalculate the target values to different scale, but adjustment of PMT voltages to a given emission filter and fluorochrome, is essential. For this purpose, EuroFlow has developed an approach using Type IIB (spectrally matching) particles to set-up standardized and fully comparable fluorescence measurements, in instruments from different manufacturers, as demonstrated here for the FACSCanto II, and Navios and MACSQuant flow cytometers. Data acquired after such adjustment on any of the tested cytometry platforms could be fully superimposed and therefore analyzed together. The proposed approach can be used to derive target values for any combination of spectrally distinct fluorochromes and any distinct emission filter of any new flow cytometry platform, which enables the measurement of the 8-color EuroFlow panels in a standardized way, by creating superimposable datafiles.
- Klíčová slova
- EuroFlow, Flow cytometry, Fluorescent spectrum, Fluorochromes, Standardization,
- MeSH
- hematologické nádory diagnóza MeSH
- imunofenotypizace přístrojové vybavení normy MeSH
- lidé MeSH
- průtoková cytometrie přístrojové vybavení normy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry.
- Klíčová slova
- EuroFlow, flow cytometry, immunophenotyping, leukemia, lymphoma, quality assessment,
- MeSH
- imunofenotypizace metody MeSH
- leukemie klasifikace diagnóza MeSH
- lymfom klasifikace diagnóza MeSH
- podskupiny lymfocytů imunologie MeSH
- průtoková cytometrie metody MeSH
- referenční hodnoty MeSH
- referenční standardy MeSH
- řízení kvality MeSH
- zdraví dobrovolníci pro lékařské studie MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Evropa MeSH
In the rapidly evolving field of primary immunodeficiencies (PID), the EuroFlow consortium decided to develop a PID orientation and screening tube that facilitates fast, standardized, and validated immunophenotypic diagnosis of lymphoid PID, and allows full exchange of data between centers. Our aim was to develop a tool that would be universal for all lymphoid PIDs and offer high sensitivity to identify a lymphoid PID (without a need for specificity to diagnose particular PID) and to guide and prioritize further diagnostic modalities and clinical management. The tube composition has been defined in a stepwise manner through several cycles of design-testing-evaluation-redesign in a multicenter setting. Equally important appeared to be the standardized pre-analytical procedures (sample preparation and instrument setup), analytical procedures (immunostaining and data acquisition), the software analysis (a multidimensional view based on a reference database in Infinicyt software), and data interpretation. This standardized EuroFlow concept has been tested on 250 healthy controls and 99 PID patients with defined genetic defects. In addition, an application of new EuroFlow software tools with multidimensional pattern recognition was designed with inclusion of maturation pathways in multidimensional patterns (APS plots). The major advantage of the EuroFlow approach is that data can be fully exchanged between different laboratories in any country of the world, which is especially of interest for the PID field, with generally low numbers of cases per center.
- Klíčová slova
- EuroFlow, automated gating strategy, flow cytometric immunophenotyping, primary immunodeficiencies, standardization,
- MeSH
- dítě MeSH
- dospělí MeSH
- imunitní systém patologie MeSH
- imunofenotypizace metody MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- předškolní dítě MeSH
- primární imunodeficience diagnóza MeSH
- průtoková cytometrie metody MeSH
- referenční standardy MeSH
- senioři MeSH
- studie případů a kontrol MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
The EuroFlow PID consortium developed a set of flow cytometry tests for evaluation of patients with suspicion of primary immunodeficiency (PID). In this technical report we evaluate the performance of the SCID-RTE tube that explores the presence of recent thymic emigrants (RTE) together with T-cell activation status and maturation stages and discuss its applicability in the context of the broader EuroFlow PID flow cytometry testing algorithm for diagnostic orientation of PID of the lymphoid system. We have analyzed peripheral blood cells of 26 patients diagnosed between birth and 2 years of age with a genetically defined primary immunodeficiency disorder: 15 severe combined immunodeficiency (SCID) patients had disease-causing mutations in RAG1 or RAG2 (n = 4, two of them presented with Omenn syndrome), IL2RG (n = 4, one of them with confirmed maternal engraftment), NHEJ1 (n = 1), CD3E (n = 1), ADA (n = 1), JAK3 (n = 3, two of them with maternal engraftment) and DCLRE1C (n = 1) and 11 other PID patients had diverse molecular defects [ZAP70 (n = 1), WAS (n = 2), PNP (n = 1), FOXP3 (n = 1), del22q11.2 (DiGeorge n = 4), CDC42 (n = 1) and FAS (n = 1)]. In addition, 44 healthy controls in the same age group were analyzed using the SCID-RTE tube in four EuroFlow laboratories using a standardized 8-color approach. RTE were defined as CD62L+CD45RO-HLA-DR-CD31+ and the activation status was assessed by the expression of HLA-DR+. Naïve CD8+ T-lymphocytes and naïve CD4+ T-lymphocytes were defined as CD62L+CD45RO-HLA-DR-. With the SCID-RTE tube, we identified patients with PID by low levels or absence of RTE in comparison to controls as well as low levels of naïve CD4+ and naïve CD8+ lymphocytes. These parameters yielded 100% sensitivity for SCID. All SCID patients had absence of RTE, including the patients with confirmed maternal engraftment or oligoclonally expanded T-cells characteristic for Omenn syndrome. Another dominant finding was the increased numbers of activated CD4+HLA-DR+ and CD8+HLA-DR+ lymphocytes. Therefore, the EuroFlow SCID-RTE tube together with the previously published PIDOT tube form a sensitive and complete cytometric diagnostic test suitable for patients suspected of severe PID (SCID or CID) as well as for children identified via newborn screening programs for SCID with low or absent T-cell receptor excision circles (TRECs).
- Klíčová slova
- EuroFlow, diagnosis, flow cytometric immunophenotyping, primary immunodeficiencies (PID), severe combined immune deficiency (SCID), standardization,
- MeSH
- HLA-DR antigeny analýza MeSH
- imunofenotypizace metody MeSH
- kojenec MeSH
- lidé MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- primární imunodeficience diagnóza imunologie MeSH
- průtoková cytometrie metody MeSH
- T-lymfocyty imunologie MeSH
- těžká kombinovaná imunodeficience imunologie MeSH
- thymus imunologie MeSH
- Check Tag
- kojenec MeSH
- lidé MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- HLA-DR antigeny MeSH
Precise classification of acute leukemia (AL) is crucial for adequate treatment. EuroFlow has previously designed an AL orientation tube (ALOT) to guide toward the relevant classification panel and final diagnosis. In this study, we designed and validated an algorithm for automated (database-supported) gating and identification (AGI tool) of cell subsets within samples stained with ALOT. A reference database of normal peripheral blood (PB, n = 41) and bone marrow (BM; n = 45) samples analyzed with the ALOT was constructed, and served as a reference for the AGI tool to automatically identify normal cells. Populations not unequivocally identified as normal cells were labeled as checks and were classified by an expert. Additional normal BM (n = 25) and PB (n = 43) and leukemic samples (n = 109), analyzed in parallel by experts and the AGI tool, were used to evaluate the AGI tool. Analysis of normal PB and BM samples showed low percentages of checks (<3% in PB, <10% in BM), with variations between different laboratories. Manual analysis and AGI analysis of normal and leukemic samples showed high levels of correlation between cell numbers (r2 > 0.95 for all cell types in PB and r2 > 0.75 in BM) and resulted in highly concordant classification of leukemic cells by our previously published automated database-guided expert-supervised orientation tool for immunophenotypic diagnosis and classification of acute leukemia (Compass tool). Similar data were obtained using alternative, commercially available tubes, confirming the robustness of the developed tools. The AGI tool represents an innovative step in minimizing human intervention and requirements in expertise, toward a "sample-in and result-out" approach which may result in more objective and reproducible data analysis and diagnostics. The AGI tool may improve quality of immunophenotyping in individual laboratories, since high percentages of checks in normal samples are an alert on the quality of the internal procedures.
- MeSH
- akutní myeloidní leukemie diagnóza MeSH
- algoritmy * MeSH
- imunofenotypizace metody MeSH
- leukocyty patologie MeSH
- lidé MeSH
- průtoková cytometrie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Guidelines for screening for primary immunodeficiencies (PID) are well-defined and several consensus diagnostic strategies have been proposed. These consensus proposals have only partially been implemented due to lack of standardization in laboratory procedures, particularly in flow cytometry. The main objectives of the EuroFlow Consortium were to innovate and thoroughly standardize the flowcytometric techniques and strategies for reliable and reproducible diagnosis and classification of PID of the lymphoid system. The proposed EuroFlow antibody panels comprise one orientation tube and seven classification tubes and corresponding databases of normal and PID samples. The 8-color 12-antibody PID Orientation tube (PIDOT) aims at identification and enumeration of the main lymphocyte and leukocyte subsets; this includes naïve pre-germinal center (GC) and antigen-experienced post-GC memory B-cells and plasmablasts. The seven additional 8(-12)-color tubes can be used according to the EuroFlow PID algorithm in parallel or subsequently to the PIDOT for more detailed analysis of B-cell and T-cell subsets to further classify PID of the lymphoid system. The Pre-GC, Post-GC, and immunoglobulin heavy chain (IgH)-isotype B-cell tubes aim at identification and enumeration of B-cell subsets for evaluation of B-cell maturation blocks and specific defects in IgH-subclass production. The severe combined immunodeficiency (SCID) tube and T-cell memory/effector subset tube aim at identification and enumeration of T-cell subsets for assessment of T-cell defects, such as SCID. In case of suspicion of antibody deficiency, PIDOT is preferably directly combined with the IgH isotype tube(s) and in case of SCID suspicion (e.g., in newborn screening programs) the PIDOT is preferably directly combined with the SCID T-cell tube. The proposed ≥8-color antibody panels and corresponding reference databases combined with the EuroFlow PID algorithm are designed to provide fast, sensitive and cost-effective flowcytometric diagnosis of PID of the lymphoid system, easily applicable in multicenter diagnostic settings world-wide.
- Klíčová slova
- EuroFlow, classification, diagnosis, flow cytometry, immunodeficiency, immunophenotyping, standardization,
- MeSH
- B-lymfocyty imunologie MeSH
- dítě MeSH
- dospělí MeSH
- imunologická paměť imunologie MeSH
- kojenec MeSH
- leukocyty imunologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- lymfocyty imunologie MeSH
- mladiství MeSH
- mladý dospělý MeSH
- novorozenec MeSH
- novorozenecký screening metody MeSH
- plazmatické buňky imunologie MeSH
- předškolní dítě MeSH
- primární imunodeficience diagnóza imunologie MeSH
- průtoková cytometrie metody MeSH
- senioři MeSH
- T-lymfocyty imunologie MeSH
- těžká kombinovaná imunodeficience diagnóza imunologie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- předškolní dítě MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH