Je něco špatně v tomto záznamu ?
An experimental, non-uremic rabbit model of peritoneal dialysis
Zunic-Bozinovski S, Lausevic Z, Krstic S, Jovanovic N, Trbojevic-Stankovic J, Stojimirovic B.
Jazyk angličtina Země Česko
NLK
Directory of Open Access Journals
od 1991
Free Medical Journals
od 1998
ProQuest Central
od 2005-01-01
Medline Complete (EBSCOhost)
od 2006-01-01
Nursing & Allied Health Database (ProQuest)
od 2005-01-01
Health & Medicine (ProQuest)
od 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
od 1998
- MeSH
- biokompatibilní materiály aplikace a dávkování farmakologie MeSH
- dialyzační roztoky škodlivé účinky MeSH
- králíci MeSH
- modely nemocí na zvířatech MeSH
- nemoci peritonea chemicky indukované prevence a kontrola MeSH
- peritoneální dialýza metody MeSH
- peritoneum účinky léků ultrastruktura MeSH
- uremie terapie MeSH
- výsledek terapie MeSH
- zaváděcí katétry MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- zvířata MeSH
Peritoneal dialysis (PD) is a well established method of depuration in uremic patients. Standard dialysis solutions currently in use are not biocompatible with the peritoneal membrane. Studying effects of dialysate on peritoneal membrane in humans is still a challenge. There is no consensus on the ideal experimental model so far. We, therefore, wanted to develop a new experimental non-uremic rabbit model of peritoneal dialysis, which would be practical, easy to conduct, not too costly, and convenient to investigate the long-term effect of dialysis fluids. The study was done on 17 healthy Chinchilla male and female rabbits, anesthetized with Thiopental in a dose of 0.5 mg/kg body mass. A catheter, specially made from Tro-soluset (Troge Medical GMBH, Hamburg, Germany) infusion system, was then surgically inserted and tunneled from animals' abdomen to their neck. The planned experimental procedure was 4 weeks of peritoneal dialysate instillation. The presented non-uremic rabbit model of peritoneal dialysis is relatively inexpensive, does not require sophisticated technology and was well tolerated by the animals. Complications such as peritonitis, dialysis fluid leakage, constipation and catheter obstruction were negligible. This model is reproducible and can be used to analyze the effects of different dialysis solutions on the rabbit peritoneal membrane.
Citace poskytuje Crossref.org
Lit.: 25
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07519609
- 003
- CZ-PrNML
- 005
- 20111210130841.0
- 008
- 090318s2008 xr e eng||
- 009
- AR
- 024 7_
- $a 10.33549/physiolres.931106 $2 doi
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Zunic-Bozinovski, S.
- 245 13
- $a An experimental, non-uremic rabbit model of peritoneal dialysis / $c Zunic-Bozinovski S, Lausevic Z, Krstic S, Jovanovic N, Trbojevic-Stankovic J, Stojimirovic B.
- 314 __
- $a Institute of Pathophysiology, School of Medicine, University of Belgrade, Belgrade
- 504 __
- $a Lit.: 25
- 520 9_
- $a Peritoneal dialysis (PD) is a well established method of depuration in uremic patients. Standard dialysis solutions currently in use are not biocompatible with the peritoneal membrane. Studying effects of dialysate on peritoneal membrane in humans is still a challenge. There is no consensus on the ideal experimental model so far. We, therefore, wanted to develop a new experimental non-uremic rabbit model of peritoneal dialysis, which would be practical, easy to conduct, not too costly, and convenient to investigate the long-term effect of dialysis fluids. The study was done on 17 healthy Chinchilla male and female rabbits, anesthetized with Thiopental in a dose of 0.5 mg/kg body mass. A catheter, specially made from Tro-soluset (Troge Medical GMBH, Hamburg, Germany) infusion system, was then surgically inserted and tunneled from animals' abdomen to their neck. The planned experimental procedure was 4 weeks of peritoneal dialysate instillation. The presented non-uremic rabbit model of peritoneal dialysis is relatively inexpensive, does not require sophisticated technology and was well tolerated by the animals. Complications such as peritonitis, dialysis fluid leakage, constipation and catheter obstruction were negligible. This model is reproducible and can be used to analyze the effects of different dialysis solutions on the rabbit peritoneal membrane.
- 650 _2
- $a zvířata $7 D000818
- 650 _2
- $a biokompatibilní materiály $x aplikace a dávkování $x farmakologie $7 D001672
- 650 _2
- $a zaváděcí katétry $7 D002408
- 650 _2
- $a dialyzační roztoky $x škodlivé účinky $7 D015314
- 650 _2
- $a modely nemocí na zvířatech $7 D004195
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a peritoneální dialýza $x metody $7 D010530
- 650 _2
- $a nemoci peritonea $x chemicky indukované $x prevence a kontrola $7 D010532
- 650 _2
- $a peritoneum $x účinky léků $x ultrastruktura $7 D010537
- 650 _2
- $a králíci $7 D011817
- 650 _2
- $a výsledek terapie $7 D016896
- 650 _2
- $a uremie $x terapie $7 D014511
- 700 1_
- $a Lausevic, Z.
- 700 1_
- $a Krstic, S.
- 700 1_
- $a Jovanovic, N.
- 700 1_
- $a Trbojevic-Stankovic, J.
- 700 1_
- $a Stojimirovic, B.
- 773 0_
- $w MED00003824 $t Physiological research $g Roč. 57, č. 2 (2008), s. 253-260 $x 0862-8408
- 856 41
- $u http://www.biomed.cas.cz/physiolres/pdf/57/57_253.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 9
- 990 __
- $a 20090317144817 $b ABA008
- 991 __
- $a 20090326113314 $b ABA008
- 999 __
- $a ok $b bmc $g 637418 $s 490194
- BAS __
- $a 3
- BMC __
- $a 2008 $b 57 $c 2 $d 253-260 $i 0862-8408 $m Physiological research $x MED00003824
- LZP __
- $a 2009-12/mkme