BACKGROUND AND OBJECTIVES: To evaluate the diagnostic performance of the measles-rubella-zoster reaction (MRZR) in a large real-world multiple sclerosis (MS) cohort. Second, to compare MRZR with the determination of oligoclonal IgG bands (OCB), oligoclonal kappa free light chain bands (oKFLC), and the KFLC index. METHODS: A single-center retrospective study was conducted at the University Hospital Ostrava (Czech Republic). Patients were eligible if aged ≥18 years with a determined clinical diagnosis. IgG antibodies against measles (M), rubella (R), and varicella zoster (Z) viruses were determined in paired CSF and serum using ELISA and MRZR indicated as positive if at least two components had an antibody index >1.4. OCB and oKFLC were detected by means of isoelectric focusing, and KFLC CSF and serum concentrations for calculation of the KFLC index were determined immunochemically. RESULTS: A total of 1,751 patients were included in the analyzed data set, which comprised 379 MS patients and 1,372 non-MS controls. The frequency of positive MRZR was higher in MS than in non-MS cases (MS 32.2 % vs non-MS 2.8 %; p < 0.001). This corresponded to a specificity of 97.2 % (95 % CI 96.1-98.0) and sensitivity of 32.2 % (95 % CI 27.5-37.2) and overall accuracy of 83.1 % (95 % CI 81.3-84.8). In comparison, the highest sensitivity of 95.6% (95 % CI 93.0-97.5) was for OCB with specificity of 86.9 % (95 % CI 84.9-88.7), followed by oKFLC with sensitivity and specificity of 94.7 % (95 % CI 91.5-96.9) and 78.4% (95 % CI 75.7-80.8), respectively, and the KFLC index with sensitivity of 92.5 % (95 % CI 86.6-96.3) and specificity of 93.5 % (95 % CI 90.5-95.9). DISCUSSION: MRZR remains a very specific test for the diagnosis of MS but has low sensitivity, which disallows its independent use. In contrast, OCB showed the highest sensitivity and thus remains the gold standard for the diagnosis of MS.
- Klíčová slova
- Kappa index, MRZ reaction, Multiple sclerosis, Oligoclonal IgG bands, Oligoclonal kappa free light chains,
- MeSH
- biologické markery MeSH
- dospělí MeSH
- herpes zoster * MeSH
- imunoglobulin G MeSH
- imunoglobuliny - kappa-řetězce MeSH
- lidé MeSH
- mladiství MeSH
- oligoklonální proužky MeSH
- retrospektivní studie MeSH
- roztroušená skleróza * MeSH
- spalničky * diagnóza MeSH
- zarděnky * diagnóza MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladiství MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- biologické markery MeSH
- imunoglobulin G MeSH
- imunoglobuliny - kappa-řetězce MeSH
- oligoklonální proužky MeSH
BACKGROUND: Serum neurofilaments (sNfs), especially the most investigated serum neurofilament light chain (sNfL), are promising biomarkers in multiple sclerosis (MS). However, their clinical utility is still limited, given the availability and costs of accessible analytical methods. The gold standard for the detection of sNfs is represented by the single molecule arrays (SIMOA). Recently, a high sensitivity enzyme-linked immunosorbent assay (hsELISA) has also been introduced. The objective of the study was to compare both assays for the determination of sNfL and neurofilament heavy chain (sNfH) concentrations in a defined MS cohort. The second objective was to identify contributing factors to sNfs concentrations determined by hsELISA. METHODS: Serum samples were collected from MS patients attending the MS Centre, University Hospital Ostrava, Czech Republic. The levels of sNfs were detected using SIMOA and hsELISA assays. RESULTS: The Spearman's rank correlation coefficient between the sNfL SIMOA and sNfL hsELISA and between the sNfH SIMOA and sNfH hsELISA was moderate rs= 0.543 (p = 0.001) and rs= 0.583 (p = 0.001), respectively. The Passing-Bablok regression analysis demonstrated bias between both methods. Equally significant bias between the methods was confirmed by the Bland-Altman plots. Furthermore, confounding factors affecting the sNfL levels were glomerular filtration rate (eGFR; 95% CI -2.34 to -0.04) and sex (95% CI -2.38 to -0.10). The sNfH levels were affected by age (95% CI 0.01 to 0.07), eGFR (95% CI -2.45 to -0.02), body mass index (BMI; 95% CI -0.31 to -0.05), and blood volume (95% CI 0.69 to 3.35). CONCLUSION: This analytical study showed significant differences between hsELISA and SIMOA methods, especially for the sNfH concentrations. We identified confounding factors for sNfs levels determined by hsELISA. The sNfs levels were influenced by renal function and sex, whilst sNfH levels were affected by age, BMI, and total blood volume.
- Klíčová slova
- High sensitivity ELISA, Multiple sclerosis, Neurofilament heavy chain, Neurofilament light chain, SIMOA,
- MeSH
- biologické markery MeSH
- ELISA MeSH
- intermediární filamenta * MeSH
- lidé MeSH
- roztroušená skleróza * diagnóza MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika MeSH
- Názvy látek
- biologické markery MeSH