• Je něco špatně v tomto záznamu ?

Solid-phase extraction of 4(5)-methylimidazole (4MeI) and 2-acetyl-4(5)-(1,2,3,4-tetrahydroxybutyl)-imidazole (THI) from foods and beverages with subsequent liquid chromatographic-electrospray mass spectrometric quantification

Klejdus B, Moravcová J, Lojková L, Vacek J, Kubán V.

. 2006 ; 29 (3) : 378-384.

Jazyk angličtina Země Německo

Perzistentní odkaz   https://www.medvik.cz/link/bmc07521341
E-zdroje Online

NLK Wiley Online Library (archiv) od 1996-01-01 do 2009-12-31

A method for the simultaneous determination of 4(5)-methylimidazole (4MeI) and 2-acetyl-4(5)-(1,2,3,4-tetrahydroxybutyl)-imidazole (THI) was developed using SPE and HPLC/MS. Solid-phase extraction using SCX Disc cartridges was used for isolation of the analytes from liquid samples. The lower LOQwas 0.1 ng/mL for 4MeI and 0.2 ng/ mL for THI. The linearity of the calibration curves was satisfactory as indicated by correlation coefficients >0.999. The CV for the intra- and inter-day precision was <5% (n = 6); the accuracy was in the range 98-103%. The recovery was > or = 97 and > or = 98% for THI and 4MeI, respectively. The method was used to determine THI and 4MeI in beverages, coffee, caramel colours and other samples.

000      
00000naa 2200000 a 4500
001      
bmc07521341
003      
CZ-PrNML
005      
20111210132812.0
008      
090415s2006 gw e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Klejdus, Bořivoj, $d 1958-2020 $7 xx0031057
245    10
$a Solid-phase extraction of 4(5)-methylimidazole (4MeI) and 2-acetyl-4(5)-(1,2,3,4-tetrahydroxybutyl)-imidazole (THI) from foods and beverages with subsequent liquid chromatographic-electrospray mass spectrometric quantification / $c Klejdus B, Moravcová J, Lojková L, Vacek J, Kubán V.
314    __
$a Department of Chemistry and Biochemistry, Mendel University of Agriculture and Forestry Brno, Czech Republic.
520    9_
$a A method for the simultaneous determination of 4(5)-methylimidazole (4MeI) and 2-acetyl-4(5)-(1,2,3,4-tetrahydroxybutyl)-imidazole (THI) was developed using SPE and HPLC/MS. Solid-phase extraction using SCX Disc cartridges was used for isolation of the analytes from liquid samples. The lower LOQwas 0.1 ng/mL for 4MeI and 0.2 ng/ mL for THI. The linearity of the calibration curves was satisfactory as indicated by correlation coefficients >0.999. The CV for the intra- and inter-day precision was <5% (n = 6); the accuracy was in the range 98-103%. The recovery was > or = 97 and > or = 98% for THI and 4MeI, respectively. The method was used to determine THI and 4MeI in beverages, coffee, caramel colours and other samples.
650    _2
$a nápoje $x analýza $7 D001628
650    _2
$a vysokoúčinná kapalinová chromatografie $7 D002851
650    _2
$a analýza potravin $7 D005504
650    _2
$a imidazoly $x chemie $x izolace a purifikace $7 D007093
650    _2
$a molekulární struktura $7 D015394
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $7 D021241
650    _2
$a financování organizované $7 D005381
700    1_
$a Moravcová, Jitka, $d 1950-2018 $7 xx0062264
700    1_
$a Lojková, Lea. $7 _BN003740
700    1_
$a Vacek, Jan, $d 1981- $7 xx0104698
700    1_
$a Kubáň, Vlastimil, $d 1944- $7 xx0031060
773    0_
$w MED00006463 $t Journal of separation science $g Roč. 29, č. 3 (2006), s. 378-384 $x 1615-9306
910    __
$a ABA008 $b x $y 9
990    __
$a 20090312170439 $b ABA008
991    __
$a 20090717112604 $b ABA008
999    __
$a ok $b bmc $g 644181 $s 497062
BAS    __
$a 3
BMC    __
$a 2006 $b 29 $c 3 $d 378-384 $i 1615-9306 $m Journal of separation science $x MED00006463
LZP    __
$a 2009-B1/vtme

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...