Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing

Dobsák P, Novakova M, Baba A, Vasku J, Isoyama T, Saito I, Abe Y, Chinzei T, Imachi K.

. 2006 ; 30 (6) : 478-487.

Jazyk angličtina Země Spojené státy americké

Perzistentní odkaz   https://www.medvik.cz/link/bmc07525718

To study the microvessels in bulbar conjunctiva, we conducted an experiment in goat with a pneumatically driven left heart bypass pump, which was replaced with an undulation pump-left ventricle assist device for 9 days. Three flow patterns were tested: complete pulsatile, continuous, and percentage of pulsatile. We studied the morphology of arterioles and venules of the bulbar conjunctiva using photograph records. The setting up of continuous flow caused global vasoconstriction (significant in venules-P < 0.05). During the pumping in the pulsatile and percentage of pulsatile modes, no significant changes of microvessel morphology were observed. The findings described could point to some disturbances in the microcirculatory bed in conditions of continuous flow.

Citace poskytuje Crossref.org

000      
00000naa 2200000 a 4500
001      
bmc07525718
003      
CZ-PrNML
005      
20111210141456.0
008      
090626s2006 xxu e eng||
009      
AR
024    __
$a 10.1111/j.1525-1594.2006.00244.x $2 doi
035    __
$a (PubMed)16734600
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Dobšák, Petr, $d 1958- $7 xx0063744
245    10
$a Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing / $c Dobsák P, Novakova M, Baba A, Vasku J, Isoyama T, Saito I, Abe Y, Chinzei T, Imachi K.
314    __
$a Clinic of Functional Diagnostics and Rehabilitation, St Anna Faculty Hospital and Masaryk University of Brno, Brno, Czech Republic. petr.dobsak@fnusa.cz
520    9_
$a To study the microvessels in bulbar conjunctiva, we conducted an experiment in goat with a pneumatically driven left heart bypass pump, which was replaced with an undulation pump-left ventricle assist device for 9 days. Three flow patterns were tested: complete pulsatile, continuous, and percentage of pulsatile. We studied the morphology of arterioles and venules of the bulbar conjunctiva using photograph records. The setting up of continuous flow caused global vasoconstriction (significant in venules-P < 0.05). During the pumping in the pulsatile and percentage of pulsatile modes, no significant changes of microvessel morphology were observed. The findings described could point to some disturbances in the microcirculatory bed in conditions of continuous flow.
650    _2
$a zvířata $7 D000818
650    _2
$a konjunktiva $x krevní zásobení $7 D003228
650    _2
$a design vybavení $7 D004867
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a kozy $7 D006041
650    _2
$a podpůrné srdeční systémy $7 D006353
650    _2
$a hemodynamika $7 D006439
650    _2
$a mikrocirkulace $7 D008833
650    _2
$a pulzatilní průtok $7 D011673
700    1_
$a Nováková, Marie, $d 1965- $7 xx0006795
700    1_
$a Baba, Atsushi
700    1_
$a Vašků, Jaromír, $d 1924-2017 $7 jk01141695
700    1_
$a Isoyama, T.
700    1_
$a Saito, I.
700    1_
$a Abe, Y. $7 gn_A_00000500
700    1_
$a Chinzei, T.
700    1_
$a Imachi, K.
773    0_
$w MED00000595 $t Artificial organs $g Roč. 30, č. 6 (2006), s. 478-487 $x 0160-564X
910    __
$a ABA008 $b x $y 8
990    __
$a 20090310084605 $b ABA008
991    __
$a 20111102142042 $b ABA008
999    __
$a ok $b bmc $g 662474 $s 519216
BAS    __
$a 3
BMC    __
$a 2006 $b 30 $c 6 $d 478-487 $i 0160-564X $m Artificial organs $x MED00000595
LZP    __
$a 2009-B4/ipme

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...