Je něco špatně v tomto záznamu ?
Voltametrické stanovení acifluorfenu, nitrofenu a osyfluorfenu na stříbrné tuhé amalgámové elektrodě a uhlíkové pastové elektrodě
[Voltammetric determination of acifluorphen, nitrophen and oxyfluorphen with solid silver amalgam and carbon paste electrodes]
V. Novotný a J. Barek
Jazyk čeština Země Česko
- MeSH
- elektrochemie metody přístrojové vybavení MeSH
- elektrody MeSH
- financování organizované MeSH
- halogenované difenylethery analýza MeSH
- herbicidy analýza MeSH
Optimum conditions are described for the determination of micromolar and submicromolar concentrations of herbicides Acifluorphen, Oxyfluorphen and Nitrophen by differential pulse voltammetry (DPV) on non-toxic solid silver amalgam electrode with modified meniscus in Britton-Robinson buffers at different pH. The detection limits are in the range 10-6-10-7 mol L-1. DPV determination of Acifluorphen in BR buffer at pH 2 using a carbon paste electrode was developed with a detection limit of 5·10-7 mol L-1.
Voltammetric determination of acifluorphen, nitrophen and oxyfluorphen with solid silver amalgam and carbon paste electrodes
Lit.: 22
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07531738
- 003
- CZ-PrNML
- 005
- 20111210152147.0
- 008
- 091023s2009 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Novotný, Vít $7 xx0099751
- 245 10
- $a Voltametrické stanovení acifluorfenu, nitrofenu a osyfluorfenu na stříbrné tuhé amalgámové elektrodě a uhlíkové pastové elektrodě / $c V. Novotný a J. Barek
- 246 11
- $a Voltammetric determination of acifluorphen, nitrophen and oxyfluorphen with solid silver amalgam and carbon paste electrodes
- 314 __
- $a Ústav analytické chemie, UNESCO Laboratoř elektrochemie životního prostředí, Univerzita Karlova, Praha
- 504 __
- $a Lit.: 22
- 520 9_
- $a Optimum conditions are described for the determination of micromolar and submicromolar concentrations of herbicides Acifluorphen, Oxyfluorphen and Nitrophen by differential pulse voltammetry (DPV) on non-toxic solid silver amalgam electrode with modified meniscus in Britton-Robinson buffers at different pH. The detection limits are in the range 10-6-10-7 mol L-1. DPV determination of Acifluorphen in BR buffer at pH 2 using a carbon paste electrode was developed with a detection limit of 5·10-7 mol L-1.
- 650 _2
- $a elektrochemie $x metody $x přístrojové vybavení $7 D004563
- 650 _2
- $a herbicidy $x analýza $7 D006540
- 650 _2
- $a halogenované difenylethery $x analýza $7 D055768
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Barek, Jiří, $d 1949- $7 jn20000400068
- 773 0_
- $w MED00011010 $t Chemické listy $g Roč. 103, č. 3 (2009), s. 217-223 $x 0009-2770
- 856 41
- $u http://chemicke-listy.cz/docs/full/2009_03_217-223.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 9
- 990 __
- $a 20091023113920 $b ABA008
- 991 __
- $a 20091023161038 $b ABA008
- 999 __
- $a ok $b bmc $g 690596 $s 552483
- BAS __
- $a 3
- BMC __
- $a 2009 $b 103 $c 3 $d 217-223 $i 0009-2770 $m Chemické listy $x MED00011010
- LZP __
- $a 2009-44/dkmv