Biosensors consist of a biological entity that recognizes the target analyte and the transducer that translates the biorecognition event into an electrical signal. The use of biological materials as recognizing elements imparts to biosensors the ability to specifically respond to the analyte of interest, distinguishing it from structurally similar compounds. Amperometric biosensors are based on measurements of the electric current resulting from the oxidation or reduction of an electroactive species, by keeping a constant potential at the working electrode. Enzymes can be immobilized in a thin layer on the transducer surface. Besides the reactive layer or membrane many biosensors contain one or several inner or outer membranes with different functions. The protective inner membrane may decrease the influence of interfering species. The outer membrane serves as a diffusion-limiting barrier to the enzyme substrate. Biosensors are considered biocompatible if their implantation does not affect normal functioning of the host medium and, vice versa, the host medium does not materially affect their normal operation. The present review focuses on the immobilisation techniques and preparation and utilization of protective inner and outer diffusionlimiting membranes of amperometric biosensors.
Membranes for amperometric biosensors
Lit.: 108
- 000
- 00000naa 2200000 a 4500
- 001
- bmc07531794
- 003
- CZ-PrNML
- 005
- 20111210152157.0
- 008
- 091026s2009 xr e cze||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a cze $b eng
- 044 __
- $a xr
- 100 1_
- $a Zajoncová, Ludmila, $d 1957- $7 jo20000082921
- 245 10
- $a Membrány pro amperometrické biosenzory / $c L. Zajoncová a K. Pospíšková
- 246 11
- $a Membranes for amperometric biosensors
- 314 __
- $a Ústav biochemie, Přírodovědecká fakulta Univerzity Palackého, Olomouc
- 504 __
- $a Lit.: 108
- 520 9_
- $a Biosensors consist of a biological entity that recognizes the target analyte and the transducer that translates the biorecognition event into an electrical signal. The use of biological materials as recognizing elements imparts to biosensors the ability to specifically respond to the analyte of interest, distinguishing it from structurally similar compounds. Amperometric biosensors are based on measurements of the electric current resulting from the oxidation or reduction of an electroactive species, by keeping a constant potential at the working electrode. Enzymes can be immobilized in a thin layer on the transducer surface. Besides the reactive layer or membrane many biosensors contain one or several inner or outer membranes with different functions. The protective inner membrane may decrease the influence of interfering species. The outer membrane serves as a diffusion-limiting barrier to the enzyme substrate. Biosensors are considered biocompatible if their implantation does not affect normal functioning of the host medium and, vice versa, the host medium does not materially affect their normal operation. The present review focuses on the immobilisation techniques and preparation and utilization of protective inner and outer diffusionlimiting membranes of amperometric biosensors.
- 650 _2
- $a biosenzitivní techniky $x metody $x přístrojové vybavení $7 D015374
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a chemické techniky analytické $x metody $7 D002623
- 700 1_
- $a Pospíšková, Kristýna, $d 1985- $7 xx0140664
- 773 0_
- $w MED00011010 $t Chemické listy $g Roč. 103, č. 4 (2009), s. 291-301 $x 0009-2770
- 856 41
- $u http://chemicke-listy.cz/docs/full/2009_04_291-301.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b B 1918 $c 395 $y 9
- 990 __
- $a 20091023113920 $b ABA008
- 991 __
- $a 20091029122006 $b ABA008
- 999 __
- $a ok $b bmc $g 690652 $s 552539
- BAS __
- $a 3
- BMC __
- $a 2009 $b 103 $c 4 $d 291-301 $i 0009-2770 $m Chemické listy $x MED00011010
- LZP __
- $a 2009-44/dkmv