Something wrong with this record ?
Determination of 1-methylhistidine and 3-methylhistidine by capillary and chip electrophoresis with contactless conductivity detection
Tůma P, Samcová E, Opekar F, Jurka V, Stulík K
Language English Country Germany
NLK
Wiley Online Library (archiv)
from 1999-01-01 to 2012-12-31
- MeSH
- Electric Conductivity MeSH
- Electrophoresis, Capillary methods MeSH
- Electrophoresis, Microchip methods instrumentation MeSH
- Financing, Organized MeSH
- Humans MeSH
- Methylhistidines analysis urine MeSH
- Check Tag
- Humans MeSH
CE with capacitively coupled contactless detection (C4D) was used to determine 3-methylhistidine (3-MH) and 1-methylhistidine (1-MH). The C4D response to 3-MH was studied in a BGE consisting of 500 mM acetic acid and ammonia at varying concentration and the results were compared with the theory. Complete separation of a model mixture of 3-MH, 1-MH, and histidine (His) was attained in two optimized BGEs, one containing 500 mM HAc, 20 mM NH4OH, and 0.1 % m/v hydroxyethylcellulose (HEC), pH 3.4 (I) and the other consisting of 100 mM morpholinoethanesulfonic acid (MES), 25 mM LiOH, and 0.1 % m/v HEC, pH 5.5 (II). These optimized BGEs were tested in CE/C4D analyses of urine. Promising results were obtained for separation and determination of 3-MH, 1-MH, and His on a silicon microchip, using aluminum strips as the C4D electrodes; the three analytes were baseline-separated within less than 30 s with a separation channel effective length of 38 mm. The LOD were satisfactory and amounted to 26.4 microM for 3-MH and 18.3 microM for 1-MH.
- 000
- 00000naa 2200000 a 4500
- 001
- bmc10001014
- 003
- CZ-PrNML
- 005
- 20111210154844.0
- 008
- 100118s2007 gw e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Tůma, Petr $7 xx0105786
- 245 10
- $a Determination of 1-methylhistidine and 3-methylhistidine by capillary and chip electrophoresis with contactless conductivity detection / $c Tůma P, Samcová E, Opekar F, Jurka V, Stulík K
- 314 __
- $a Institute of Biochemistry, Cell and Molecular Biology, 3rd Faculty of Medicine, Charles University, Prague, Czech Republic. petr.tuma@lf3.cuni.cz
- 520 9_
- $a CE with capacitively coupled contactless detection (C4D) was used to determine 3-methylhistidine (3-MH) and 1-methylhistidine (1-MH). The C4D response to 3-MH was studied in a BGE consisting of 500 mM acetic acid and ammonia at varying concentration and the results were compared with the theory. Complete separation of a model mixture of 3-MH, 1-MH, and histidine (His) was attained in two optimized BGEs, one containing 500 mM HAc, 20 mM NH4OH, and 0.1 % m/v hydroxyethylcellulose (HEC), pH 3.4 (I) and the other consisting of 100 mM morpholinoethanesulfonic acid (MES), 25 mM LiOH, and 0.1 % m/v HEC, pH 5.5 (II). These optimized BGEs were tested in CE/C4D analyses of urine. Promising results were obtained for separation and determination of 3-MH, 1-MH, and His on a silicon microchip, using aluminum strips as the C4D electrodes; the three analytes were baseline-separated within less than 30 s with a separation channel effective length of 38 mm. The LOD were satisfactory and amounted to 26.4 microM for 3-MH and 18.3 microM for 1-MH.
- 650 _2
- $a financování organizované $7 D005381
- 650 _2
- $a elektrická vodivost $7 D004553
- 650 _2
- $a elektroforéza kapilární $x metody $7 D019075
- 650 _2
- $a elektroforéza mikročipová $x metody $x přístrojové vybavení $7 D046209
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a methylhistidiny $x analýza $x moč $7 D008762
- 700 1_
- $a Samcová, Eva, $d 1947- $7 nlk19990073817
- 700 1_
- $a Opekar, František. $7 _BN004560
- 700 1_
- $a Jurka, Vlastimil. $7 xx0303001
- 700 1_
- $a Štulík, Karel, $d 1941-2013 $7 jk01131560
- 773 0_
- $w MED00001508 $t Electrophoresis $g Roč. 28, č. 13 (2007), s. 2174-2180 $x 0173-0835
- 910 __
- $a ABA008 $b x $y 8
- 990 __
- $a 20100114083259 $b ABA008
- 991 __
- $a 20100215154206 $b ABA008
- 999 __
- $a ok $b bmc $g 703742 $s 566184
- BAS __
- $a 3
- BMC __
- $a 2007 $b 28 $c 13 $d 2174-2180 $i 0173-0835 $m Electrophoresis $x MED00001508
- LZP __
- $a 2010-b1/vtme