On-line coupling of sequential injection extraction with restricted-access materials and post-column derivatization for sample clean-up and determination of propranolol in human plasma

D Satinsky, HS Serralheiro, P Solich, AN Araujo, MC Montenegro

. 2007 ; 600 (1-2) : 122-128.

Jazyk angličtina Země Nizozemsko

Perzistentní odkaz   https://www.medvik.cz/link/bmc10005863

The presented paper deals with a new methodology for direct determination of propranolol in human plasma. The methodology described is based on sequential injection analysis technique (SIA) coupled with solid phase extraction (SPE) column based on restricted access materials (RAM). Special RAM column containing 30 microm polymeric material-N-vinylacetamide copolymer was integrated into the sequential injection manifold. SIA-RAM system was used for selective retention of propranolol, while the plasma matrix components were eluted with two weak organic solutions to waste. Due to the acid-basic and polarity properties of propranolol molecule and principles of reversed-phase chromatography, it was possible to retain propranolol on the N-vinylacetamide copolymer sorbent (Shodex MSpak PK-2A 30 microm (2 mm x 10 mm)). Centrifuged plasma samples were aspirated into the system and loaded onto the column using acetonitrile-water (5:95, v/v), pH 11.00, adjusted by triethylamine. The analyte was retained on the column while proteins contained in the sample were removed to waste. Interfering endogenous substances complicating detection were washed out by acetonitrile-water (15:85), pH 11.00 in the next step. The extracted analyte was eluted by means of tetrahydrofuran-water (25:75), pH 11.00 to the fluorescence detector (emission filter 385 nm). The whole procedure comprising sample pre-treatment, analyte detection and column reconditioning took about 15 min. The recoveries of propranolol from undiluted plasma were in the range 96.2-97.8% for three concentration levels of analyte. The proposed SIA-RAM method has been applied for direct determination of propranolol in human plasma.

Citace poskytuje Crossref.org

000      
03203naa 2200349 a 4500
001      
bmc10005863
003      
CZ-PrNML
005      
20111210160834.0
008      
100310s2007 ne e eng||
009      
AR
024    __
$a 10.1016/j.aca.2007.02.021 $2 doi
035    __
$a (PubMed)17903473
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a ne
100    1_
$a Šatínský, Dalibor $7 xx0019028
245    10
$a On-line coupling of sequential injection extraction with restricted-access materials and post-column derivatization for sample clean-up and determination of propranolol in human plasma / $c D Satinsky, HS Serralheiro, P Solich, AN Araujo, MC Montenegro
314    __
$a Department of Analytical Chemistry, Faculty of Pharmacy, Charles University, Heyrovskeho 1203, Hradec Kralove 500 05, Czech Republic.
520    9_
$a The presented paper deals with a new methodology for direct determination of propranolol in human plasma. The methodology described is based on sequential injection analysis technique (SIA) coupled with solid phase extraction (SPE) column based on restricted access materials (RAM). Special RAM column containing 30 microm polymeric material-N-vinylacetamide copolymer was integrated into the sequential injection manifold. SIA-RAM system was used for selective retention of propranolol, while the plasma matrix components were eluted with two weak organic solutions to waste. Due to the acid-basic and polarity properties of propranolol molecule and principles of reversed-phase chromatography, it was possible to retain propranolol on the N-vinylacetamide copolymer sorbent (Shodex MSpak PK-2A 30 microm (2 mm x 10 mm)). Centrifuged plasma samples were aspirated into the system and loaded onto the column using acetonitrile-water (5:95, v/v), pH 11.00, adjusted by triethylamine. The analyte was retained on the column while proteins contained in the sample were removed to waste. Interfering endogenous substances complicating detection were washed out by acetonitrile-water (15:85), pH 11.00 in the next step. The extracted analyte was eluted by means of tetrahydrofuran-water (25:75), pH 11.00 to the fluorescence detector (emission filter 385 nm). The whole procedure comprising sample pre-treatment, analyte detection and column reconditioning took about 15 min. The recoveries of propranolol from undiluted plasma were in the range 96.2-97.8% for three concentration levels of analyte. The proposed SIA-RAM method has been applied for direct determination of propranolol in human plasma.
650    _2
$a kalibrace $7 D002138
650    _2
$a průtoková injekční analýza $x metody $x přístrojové vybavení $7 D017022
650    _2
$a lidé $7 D006801
650    _2
$a koncentrace vodíkových iontů $7 D006863
650    _2
$a molekulární struktura $7 D015394
650    _2
$a on-line systémy $x přístrojové vybavení $7 D009862
650    _2
$a propranolol $x chemie $x krev $7 D011433
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a financování organizované $7 D005381
700    1_
$a Serralheiro, Hugo S
700    1_
$a Solich, Petr, $d 1955- $7 jo2007285395
700    1_
$a Araujo, Araugo Alberto N $7 gn_A_00008031
700    1_
$a Montenegro, Maria C
773    0_
$w def $t Analytica Chimica Acta $g Roč. 600, č. 1-2 (2007), s. 122-128
910    __
$a ABA008 $b x $y 8
990    __
$a 20100310151759 $b ABA008
991    __
$a 20100916113204 $b ABA008
999    __
$a ok $b bmc $g 715272 $s 578247
BAS    __
$a 3
BMC    __
$a 2007 $b 600 $c 1-2 $d 122-128 $m Analytica chimica acta $n Anal. chim. acta (Print) $x MED00000332
LZP    __
$a 2010-B2/dkme

Najít záznam

Citační ukazatele

Nahrávání dat ...