Two-dimensional and serial column reversed-phase separation of phenolic antioxidants on octadecyl-, polyethyleneglycol-, and pentafluorophenylpropyl-silica columns
E Blahova, P Jandera, F Cacciola, L Mondello
Language English Country Germany
Document type Evaluation Study
NLK
Wiley Online Library (archiv)
from 1996-01-01 to 2009-12-31
- MeSH
- Antioxidants analysis MeSH
- Phenols analysis MeSH
- Financing, Organized MeSH
- Humans MeSH
- Silicon Dioxide chemistry MeSH
- Polyethylene Glycols chemistry MeSH
- Plant Extracts chemistry MeSH
- Chromatography, High Pressure Liquid methods instrumentation MeSH
- Check Tag
- Humans MeSH
- Publication type
- Evaluation Study MeSH
The separation selectivity of octadecyl-silica (C18) and of bonded pentafluorophenylpropyl-silica (F5) and PEG-silica columns was compared for natural phenolic antioxidants. The separation selectivities for phenolic antioxidants on C18 and F5 columns are strongly correlated, but low selectivity correlation indicating strong differences in the retention mechanism was observed between the C18 and PEG columns. Hence, the combination of a C18 and a PEG column is useful for separation of phenolic antioxidants that are not fully separated on single columns. Two-dimensional comprehensive liquid chromatography using a short PEG-silica column in the first dimension and a conventional C18-silica in the second dimension has the advantage of on-column focusing of the fractions transferred onto the C18 column in the second dimension, as a weaker mobile phase is used in the first dimension than in the second dimension. However, a stop-flow set-up in the first dimension system is necessary after the transfer of each fraction to the second dimension. Peak capacity is considerably larger but the separation time is much longer than with serially coupled PEG and C18 columns, which were employed for separation of beer and hop extract samples in connection with coulometric detection.
- 000
- 02765naa 2200349 a 4500
- 001
- bmc10012794
- 003
- CZ-PrNML
- 005
- 20121031103812.0
- 008
- 100527s2006 gw e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Bláhová, Eva. $7 _AN049451
- 245 10
- $a Two-dimensional and serial column reversed-phase separation of phenolic antioxidants on octadecyl-, polyethyleneglycol-, and pentafluorophenylpropyl-silica columns / $c E Blahova, P Jandera, F Cacciola, L Mondello
- 314 __
- $a Department of Analytical Chemistry, University of Pardubice, Pardubice, Czech Republic.
- 520 9_
- $a The separation selectivity of octadecyl-silica (C18) and of bonded pentafluorophenylpropyl-silica (F5) and PEG-silica columns was compared for natural phenolic antioxidants. The separation selectivities for phenolic antioxidants on C18 and F5 columns are strongly correlated, but low selectivity correlation indicating strong differences in the retention mechanism was observed between the C18 and PEG columns. Hence, the combination of a C18 and a PEG column is useful for separation of phenolic antioxidants that are not fully separated on single columns. Two-dimensional comprehensive liquid chromatography using a short PEG-silica column in the first dimension and a conventional C18-silica in the second dimension has the advantage of on-column focusing of the fractions transferred onto the C18 column in the second dimension, as a weaker mobile phase is used in the first dimension than in the second dimension. However, a stop-flow set-up in the first dimension system is necessary after the transfer of each fraction to the second dimension. Peak capacity is considerably larger but the separation time is much longer than with serially coupled PEG and C18 columns, which were employed for separation of beer and hop extract samples in connection with coulometric detection.
- 650 _2
- $a antioxidancia $x analýza $7 D000975
- 650 _2
- $a vysokoúčinná kapalinová chromatografie $x metody $x přístrojové vybavení $7 D002851
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a fenoly $x analýza $7 D010636
- 650 _2
- $a rostlinné extrakty $x chemie $7 D010936
- 650 _2
- $a polyethylenglykoly $x chemie $7 D011092
- 650 _2
- $a oxid křemičitý $x chemie $7 D012822
- 650 _2
- $a financování organizované $7 D005381
- 655 _2
- $a hodnotící studie $7 D023362
- 700 1_
- $a Jandera, Pavel, $d 1944-2021 $7 jn20000710061
- 700 1_
- $a Cacciola, Francesco
- 700 1_
- $a Mondello, Luigi
- 773 0_
- $t Journal of Separation Science $w MED00006463 $g Roč. 29, č. 4 Mar (2006), s. 555-566 $x 1615-9306
- 910 __
- $a ABA008 $b x $y 8
- 990 __
- $a 20100601124952 $b ABA008
- 991 __
- $a 20121031103815 $b ABA008
- 999 __
- $a ok $b bmc $g 726649 $s 589806
- BAS __
- $a 3
- BMC __
- $a 2006 $b 29 $c 4 Mar $d 555-566 $i 1615-9306 $m Journal of separation science $n J Sep Sci $x MED00006463
- LZP __
- $a 2010-B2/vtme