• Je něco špatně v tomto záznamu ?

Stanovení ultrastopových koncentrací selenu a arsenu v pitných vodách metodou ECHG-QFAAS
[Determination of ultratrace selenium and arsenic in drinking water by electrochemical hydride generation coupled with quartz furnace - Atomic Absorption Spectrometry]

Jakub Hraníček, Václav Červený, Petr Rychlovský

. 2010 ; 104 (12) : 1196-1203.

Jazyk čeština Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc10036417

The aim of this study was to develop a method of Se and As determination in drinking water by electrochemical hydride generation coupled with AAS. Three types of electrolytic cells were constructed and optimized for the determination. Two cells (thin-layer and tubular) were finally chosen for their low inner volume and a high hydride generation efficiency (ca. 90 %). The limits of detection of As(III) and Se(IV) were 0.07 and 0.37 ng ml–1, respectively. The accuracy of the method was verified using reference materials.

Determination of ultratrace selenium and arsenic in drinking water by electrochemical hydride generation coupled with quartz furnace - Atomic Absorption Spectrometry

Bibliografie atd.

Lit.: 19

000      
00000naa 2200000 a 4500
001      
bmc10036417
003      
CZ-PrNML
005      
20111210200858.0
008      
110112s2010 xr e cze||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a cze $b eng
044    __
$a xr
100    1_
$a Hraníček, Jakub. $7 uk2013769293
245    10
$a Stanovení ultrastopových koncentrací selenu a arsenu v pitných vodách metodou ECHG-QFAAS / $c Jakub Hraníček, Václav Červený, Petr Rychlovský
246    11
$a Determination of ultratrace selenium and arsenic in drinking water by electrochemical hydride generation coupled with quartz furnace - Atomic Absorption Spectrometry
314    __
$a Univerzita Karlova v Praze, Přírodovědecká fakulta, Katedra analytické chemie, Albertov 2030, 128 43 Praha 2
504    __
$a Lit.: 19
520    9_
$a The aim of this study was to develop a method of Se and As determination in drinking water by electrochemical hydride generation coupled with AAS. Three types of electrolytic cells were constructed and optimized for the determination. Two cells (thin-layer and tubular) were finally chosen for their low inner volume and a high hydride generation efficiency (ca. 90 %). The limits of detection of As(III) and Se(IV) were 0.07 and 0.37 ng ml–1, respectively. The accuracy of the method was verified using reference materials.
650    _2
$a zásobování vodou $7 D014881
650    _2
$a chemické znečištění vody $x analýza $7 D014877
650    _2
$a arsen $x analýza $7 D001151
650    _2
$a selen $x analýza $7 D012643
650    _2
$a elektrochemie $x metody $x přístrojové vybavení $7 D004563
650    _2
$a vysokoúčinná kapalinová chromatografie $x metody $x přístrojové vybavení $7 D002851
700    1_
$a Červený, Václav, $d 1981- $7 uk2007300490
700    1_
$a Rychlovský, Petr. $7 _gn010004101
773    0_
$w MED00011010 $t Chemické listy $g Roč. 104, č. 12 (2010), s. 1196-1203 $x 0009-2770
856    41
$u http://www.chemicke-listy.cz/docs/full/2010_12_1196-1203.pdf $y plný text volně přístupný
910    __
$a ABA008 $b B 1918 $c 395 $y 7
990    __
$a 20110107144915 $b ABA008
991    __
$a 20110112091121 $b ABA008
999    __
$a ok $b bmc $g 825234 $s 690340
BAS    __
$a 3
BMC    __
$a 2010 $b 104 $c 12 $m Chemické listy $x MED00011010 $d 1196-1203
LZP    __
$a 2011-02/vtmv

Najít záznam